My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 13TH ST 9TH FLOOR 2022-01-20
>
Address Records
>
13TH ST
>
1700
>
9TH FLOOR
>
1700 13TH ST 9TH FLOOR 2022-01-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2022 3:05:06 PM
Creation date
5/4/2021 2:09:34 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1700
Tenant Name
9TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. Listings and references should be provided for the partition STC's shown on Sheet A8.01 <br />where required by Section 1207.2 <br />6. Walls separating the sleeping rooms from each other and sleeping rooms from the <br />corridor/other rooms (FbA, NbA, NA, etc.) shown with assemblies that have less than 50 <br />STC on Sheet A8.01. Section 1207.2 <br />7. It should be verified that the existing walls and doors of electrical rooms B90040 & B9104 <br />that are part of the smoke barrier are appropriately rated. Section 709 <br />8. The plans should state that fire-resistant penetrations and joints will be special inspected <br />in accordance with Section 1705.17. <br />9. The fire safety and response plan for the 9th floor as specified in IFC Section 403.8 should <br />be forwarded to the fire marshal for approval. <br />Egress <br />1. The Family Lounge is shown with an occupant load greater than 50. Please note that we <br />would normally assign an occupant load factor (OLF) of 15 to such a space which would <br />not result in an occupant load greater than 50. If the OLF of 7 is truly representative of <br />the use of the space the following comments apply: <br />a. The occupancy should be revised to Assembly per Section 303.1. <br />b. All doors leading from the room should be shown with panic hardware on the door <br />schedule per Section 1010.1.10 (also note that door A9030 is not on the door <br />schedule). <br />c. The maximum occupant load should be posted in the room. <br />2. Family Conference room B9073A should also be provided with a side -hinged door. Section <br />1010.1.2 <br />3. Please confirm that doors opening into the corridors do not utilize roller latches. Section <br />407.3.1 <br />4. Please confirm that the doors leading from the electrical rooms are either provided with <br />panic hardware or are not required to have panic devices per Section 1010.1.10.3 <br />5. Please confirm that the existing electrical rooms are not required to have two means of <br />egress per Section 1006.2.2.6 and NEC Article 110.26 (C)(3). <br />6. The locations, use -instructions and signage requirements for the two-way communication <br />system at the elevator landings should be shown on the plans. Section 1009.8 <br />7. Any electric/electromechanical controlled egress doors proposed should be shown to <br />comply with Section 1010.1.9.6. <br />Accessibility <br />3200 Cedar Street <br />© <br />425.257.8810 <br />(atlee@everettwa.gov <br />Everett, WA 98201 <br />425.257.8857 fax <br />everettwa.gov <br />�_J ) <br />
The URL can be used to link to this page
Your browser does not support the video tag.