My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1913 HOYT AVE WHOLE SITE 2022-05-23
>
Address Records
>
HOYT AVE
>
1913
>
WHOLE SITE
>
1913 HOYT AVE WHOLE SITE 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 7:57:47 AM
Creation date
5/4/2021 2:11:26 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
1913
Tenant Name
WHOLE SITE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0RTE <br /> MEMBER REPORT Upper Floor Framing, U-09 Window header PASSED <br /> 1 piece(s) 4 x 6 Douglas Fir-Larch No. 2 <br /> Overall Length:4'3" <br /> + + <br /> 4'3' <br /> 4. 4, <br /> 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).AII dimensions are horizontal.;Drawing is Conceptual <br /> j Design Results Actual 0 Location Allowed Result LOF Load:Combination(Pattern) System:Wall <br /> Member Reaction(lbs) 1385 @ 4'3" 3281(1.50") Passed(42%) -- 1.0 D+ 1.0 L(All Spans) Member Type:Header <br /> Shear(Ibs) 997 @ 3'8" 2310 Passed(43%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Moment(Ft-lbs) 1424 @ 2'1 9/16" 1720 Passed(83%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2015 <br /> Live Load Defl.(in) 0.038 @ 2'1 9/16" 0.142 Passed(L/999+) -- 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> LI Total Load Defl.(in) 0.060 @ 2'1 9/16" 0.213 Passed(L/847) -- 1.0 D+1.0 L(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> •Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 4'3"o/c unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> ' Bearing Loads to Supports(Ibs) <br /> I1 Supports - Total Available Required Dead Floor Snow Total Accessories <br /> Live <br /> 1-Trimmer-HF 1.50" 1.50" 1.50" 534 850 254 1638 None <br /> 2-Trimmer-I-IF 1.50" 1.50" 1.50" 535 850 253 1638 None <br /> Tributary Dead Floor Live Snow <br /> Loads Location(Side) Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 4'3" N/A 4.9 <br /> 1-Uniform(PSF) 0 to 4'3" 10' 10.0 40.0 - Residential-Living <br /> Areas <br /> 2-Uniform(PSF) 0 to 1'1" 4'6" 11.2 - 25.0 Snow <br /> 3-Uniform(PSF) 3'1"to 4'3" 4'6" 11.2 - 25.0 Snow <br /> 4-Uniform(PLF) 1'1"to 3'1" N/A 70.0 - - Wail <br /> 5-Uniform(PLF) 0 to 1'1" N/A 110.0 - - Wall <br /> 6-Uniform(PLF) 3'1"to 4'3" N/A 110.0 - - Wall <br /> Linked from:R-06 <br /> 7-Point(lb) 1'1" N/A 61 - 127 Window header, <br /> Support 1 <br /> Linked from:R-06 <br /> 8-Point(lb) 3'1" N/A 61 - 127 Window header, <br /> Support 2 <br /> Member Notes II <br /> Dining room window <br /> Weyerhaeuser Notes; @SUSTAINABLE FORESTRY a mATlVE <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. @SUSTAINABLE <br /> expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. <br /> (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to <br /> circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to <br /> assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable <br /> forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in <br /> accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. <br /> The product application,input design loads,dimensions and support information have been provided by Forte Software Operator <br /> Forte Software Operator Job Notes 1/6/2017 10:24:05 AM <br /> t <br /> Forte v5.2.Design Engine:V6.6 0.14 <br /> DFamcll Duplex 147E <br /> r,sim:-ijnCF Duplex 14i0.4`e <br /> 3_C53^ <br /> ..S1,1,1:r..e9 rorr; <br />
The URL can be used to link to this page
Your browser does not support the video tag.