Month DID, YYYYY <br />5. Please include the existing doors required to have panic hardware (as these will need to be inspected) <br />on the door schedule (includes doors #178, 178AA, 186A, 186B, 186C, 187, 187AA, 190 & 190AA). <br />Section 1010.1.10. We have added Coded Note 2, indicating Panic Hardware, to the door schedule for <br />these doors. <br />t/ 6. The handrails serving the stage stairs should be shown with extensions past the top`of the stairs. <br />Section 1014.6. The handrail extension is shown on 16/A6.04. <br />�7. The handrail extension shown at the bottom of the stairs as shown in Section 2 on Sheets A6.01 & <br />A6.02 should be shown to continue at the same slope as the handrail. Section 1014.6. This has been <br />corrected. See 4/A6.01 & 4/A6.02. <br />8. Please provide or direct us to a construction detail of the 2" d story guards. Section 1015. Guards at <br />Level are on SheetA6.07, and are referenced from the enlarged stair plans. <br />/9. Braille exit signs stating EXIT should be shown at each exit stairway and exit discharge. Section <br />1013.4. Braille exit signs are called at Leve12 stair landings, see n/A6.01, 2/A6.02 & 2/A6.03. Braille <br />exit signs are called out at Level 1 via 'BES" notations on Sheet G1.01. <br />Accessibility <br />1 The existing parking lot at 261' and Rainier has 99 parking stalls but only 2 accessible stalls shown. A <br />✓ minimum of 4 accessible parking stalls should be provided in this lot per Section 1106.1. As an <br />alternative, two additional spaces may be added to the new western lotus that lot is on the shortest; <br />accessible route to the building. Section 1106.6. Two additional stalls have been added the new <br />western lot. Refer to Sheet C6.02 <br />/2. An ambulatory toilet stall should be shown in Boy's Room 170A. Section 1109.2.2. An ambulatory stall <br />has been added. Refer to 5/A7.01 <br />The ambulatory toilet stall in Girl's Room 170B should be shown with grab bars. Section 1109.2.2. <br />/ Grab bars have been added. Refer to 5/A7.01 <br />4. The p <br />exposed pipes and surfaces under the accessible lavatories on Sheet A7.01 should be shown to <br />p <br />be guarded from contact. ANSI Section 606.6. Insulation of exposed supply and waste piping is called <br />r in specifications section 224000. Refer to items K, L and M on the attached partial specifications <br />section 224000 - Plumbing Fixtures. <br />5. The accessible transfer shower stalls in Coach's Office 172D and group shower 172B should be shown <br />with the required clear floor space (the showers may need to be mirrored). ANSI Section 608.2.1.2. <br />The shower stalls have been reconfigured to have the correct relationship between clear floor space <br />and shower/bench. Refer to 1 & 2A/A7.03 <br />L <br />