Laserfiche WebLink
Month DD, YYYY <br />_ _ 4_a� <br />/6. The transfer shower stall in Room 121 appears to be deeper than the 36" specified in ANSI Section <br />608.2.1. A deeper stall will compromise the clear floor space and seat requirements. The depth has <br />been corrected. Refer to 3A/A7.02 <br />;1/7. The compliance method with ANSI Section 606.2 for the sinks provided within the classrooms should <br />be clarified. Section 1109.3. Classroom sinks are mounted within cabinet type G-1, in which the <br />finish floor extends below the counter allowing for a front approach. Refer to Sheet A5.50. The <br />specified sink is an ADA compliant model with a faucet and bubbler. Refer to attached <br />manufacturer's cut sheet for the specified product: JUST CRAF-1928 A-GR-VRL-CT. <br />8. Door 221 B from the library to the storage should be shown with a minimum of 18" clearance <br />between the door and the built-in cabinets. ANSI Section 404.2.3.4. Casework within Storage 221B <br />has been revised. Door 221B now has the 18" clearance. <br />En rgy <br />1. We have the energy code compliance sheets for Mechanical and Lighting, however cannot locate the <br />sheets for Envelope. Please resubmit. The envelope compliance sheets are attached. g <br />✓2. Air barrier and testing requirements should be shown on the plans Per WSEC Section C402.5. Air <br />barrier testing notes have been added to Sheet 62.01. The referenced specification Section 014100 <br />Air Barrier System is also attached. <br />We trust that these responses adequately address the issues identified in the correction notice. We are <br />submitting two replacement sets of drawings which contain the referenced new/updated drawing <br />information. Additionally we have enclosed supplementary items referenced in our responses. Please contact <br />us if you have any questions or desire further clarification. <br />Sincerely, <br />Mark Gifford, AIA <br />Associate Principal <br />cc: Steven Krause, Everett Public Schools <br />enc: Partial spec section 224000 - Plumbing Fixtures <br />Manufacturer's cut sheet for JUST CRAF-1928-A-GR-VRL-CT <br />Energy code compliance sheets ENV-SHGC & ENV-UA <br />Spec section 014100 - Air Barrier System <br />n:\121-16027\04_regulatory\b_building\bui Idi ngpermitreview\b1711-002-003-resubmittalltr.docx <br />