Laserfiche WebLink
Ms. Clover Schuler <br /> Magellan Architects <br /> Plan Check Number: B1810-012, First Review <br /> November 7, 2018 <br /> d. Means of egress illumination shall be provided in the room and in the hallways leading <br /> to the exits. See IBC Section 1008.3.1. The lighting shall require an emergency power <br /> supply per IBC Section 1008.3.4. <br /> MA response: This has been addressed on sheet A0.4 <br /> e. The exterior landings for exit doors serving the room shall be provided with emergency <br /> lighting. The lighting shall require an emergency power supply per IBC Section <br /> 1008.3.4. See IBC Sections 1008.3.2 Item 5 and 1010.1.6. <br /> MA response: This has been addressed on sheet A0.4 <br /> f. The occupant load shall be posted near the main exit per IBC Section 1004.3. <br /> MA response: This has been addressed on sheet A0.4 <br /> g. The doors shall be provided with panic hardware per IBC Section 1010.1.10. <br /> MA response: This has been addressed on sheet A7.1 <br /> h. Continuing with the previous comment, all doors in the exit access shall similarly be <br /> provided with panic hardware. See Section 202 for the definition of the exit access. <br /> MA response: This has been addressed on sheet AZ1 <br /> 5. The egress for the 2nd Story office area shown on Sheet A0.4 is affected by the alterations <br /> to the waiting and counter areas. The office area has an occupant load of over 100 and <br /> requires two exits per IBC Section 1006.2.1 and Table 1006.2.1. See also IEBC Section <br /> 805.4.1.1. The following comments shall be addressed: <br /> a. Exit signs shall be provided at each door. In addition, exit signs shall be provided along <br /> the exit access (i.e., hallways and stairs), including intervening doors. Direction arrows <br /> shall be provided where required. Additional signs shall be provided where the path of <br /> egress travel is not visible (e.g., room corners, etc.). See IBC Section 1013.1. <br /> MA response: This has been addressed on sheet A0.4 <br /> b. Means of egress illumination shall be provided in the room, stairways, and hallways <br /> leading to the exits. See IBC Section 1008.3.1. The lighting shall require an emergency <br /> power supply per IBC Section 1008.3.4. <br /> MA response: This has been addressed on sheet 110.4 <br /> c. The exterior landings for exit doors serving the room shall be provided with emergency <br /> lighting. The lighting shall require an emergency power supply per IBC Section <br /> 1008.3.4. See IBC Sections 1008.3.2 Item 5 and 1010.1.6. <br /> MA response: This has been addressed on sheet A0.4 <br /> d. The doors shall be provided with panic hardware per IBC Section 1010.1.10. <br /> MA response: This has been addressed on sheet AZ1 <br /> e. Continuing with the previous comment, all doors in the exit access shall similarly be <br /> provided with panic hardware. See Section 202 for the definition of the exit access. <br /> MA response: This has been addressed on sheet AZ1 <br /> (� 3200 Cedar Street 0 425.257.8800 everettpw@everettwa.gov <br /> v Everett,WA 98201 425.257.8882 fax • everettwa.gov <br /> (-3-/(0 <br />