View Ridge Community Church <br /> Plan Check Number: B1803-040, First Review <br /> May 25, 2018 <br /> that the cuts are acceptable for the beam performance. In addition, an evaluation of the <br /> stresses in the continuous portion of the beams should be submitted for review. See IBC <br /> Sections 104.11.1 and 1604.1. <br /> 19.The area north of Wall Line A/3-4 on Sheet S-4 appears to be framed with TJI 210. The <br /> framing does not specify a connection for the joists at the existing concrete wall. A connection <br /> should be specified. Calculations substantiating the connection should be submitted for review. <br /> It appears based on Sheet S-5 and the North Elevation on Sheet 1-of-9 that the east wall is <br /> supported on the joists instead of the existing wall. The design should include the structure <br /> and superimposed loads above as needed. See IBC Sections 107.2.1 and 1604.1. <br /> Lateral System: <br /> 20.The calculations in the`Lateral Analysis"section for the seismic lateral forces are not clear. <br /> See IBC Sections 1613.1 and ASCE 7-10 Section 12.7.2. Additional documentation <br /> substantiating the forces should be submitted as follows: <br /> a. The diaphragm areas do not appear to correspond to the building. The areas are not <br /> consistent with the areas shown on Sheet 4-of-9. While it is understood that the <br /> architectural and structural areas may differ, it is expected that the"Main Floor"areas <br /> should approximately correspond to the roof areas, which they do not. Diagrams clarifying <br /> how the areas were determined should be submitted for review. <br /> b. Documentation substantiating the unit weights for the diaphragms and walls should be <br /> submitted for review. The documentation should include diagrams clarifying the <br /> diaphragms and walls to which each value applies. <br /> c. Continuing with the previous comment, the wall weights appear to be a combination of the <br /> 10 psf-value per ASCE 7-10 Section 12.7.2 Item 2, 15 psf-value per ASCE 7-10 Section <br /> 4.3.2, and user-estimated weights. In addition, it appears the calculations include areas <br /> without and without uniform superimposed wall weights, and line loads that are only <br /> applied in one direction. The calculations should be clarified. <br /> d. The summation of the longitudinal and transverse seismic weights is not clear. <br /> e. The summed effective seismic weights of 345k and 314 kips are not used to calculate the <br /> story forces and base shears. The values used are less than the summed values. <br /> Clarification should be provided on the appropriate values. <br /> 21.The lateral load path for the addition in the east-west direction appears to require tying the <br /> addition to the existing diaphragm. Documentation shall be submitted for review <br /> substantiating the design forces per ASCE 7-10 Section 12.10.1.1. See also comments below <br /> regarding additional loads on the Main Floor diaphragm from the east retaining wall. See IBC <br /> Section 1613.1. <br /> 22. Calculations for the capacities of the diaphragms shall be submitted for review. See IBC <br /> Section 1604.2. The calculations should address the following: <br /> a. The diaphragm capacities, including the existing diaphragm areas. Where existing <br /> diaphragms are connection to shear walls and collectors, the existing capacities shall <br /> control the design. <br /> b. The capacity of diaphragm-to-foundation wall connections, particularly in the east-west <br /> direction. The connection forces shall be increased as required by ACI 318-14 Section <br /> 17.2.3.5.3. See IBC Section 1901.2. <br /> "Page 10 of 12_,._.\ <br /> CITY OF EVERETT • 3200 Cedar Street • Everett,WA 98201 • (425) 257-8810 • Fax(425) 257=8857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.