48. A One -flour Fire -Resistive Occupancy Separatior. <br />is required between the boiler or central heal. <br />Ing plant and the rest of the building. Section <br />808. <br />Group D <br />49. <br />Group D. Division 1 Occupancies should be of <br />Type I or II construction unless complying with <br />the Exception in Section 902 (b), <br />57. <br />Group D. Division 2 (3) Occupancies should be <br />of one -hour fire -resistive construction. Table <br />No. S.C. <br />51. <br />Light and ventilation should comply with Section <br />905. <br />52. <br />A One -Hour Fire -Resistive Occupancy Separation <br />is required between the boiler or central heat- <br />ing plant and the rest of the building. Section <br />908. <br />53. <br />Exterior openings for rooms containing a boiler <br />or central heating plant should be protected <br />with three4ourths-hour fire -resistive assemblies <br />that are fixed, automatic, or sell -closing if <br />located below openings in another story or if <br />less than 10 feet from other doors or windows <br />in the same building. Section 908. <br />Group F <br />5a. <br />Motor vehicle service stations should be of non• <br />combustible fire -retardant treated wood or one. <br />hour fire -resistive construction. Section 1102 <br />(b). <br />55. <br />Storage areas in excess of 1000 square feet in <br />connection -with wholesale or retail sales should <br />be separated from the public areas by a One. <br />Hour Fire -Resistive Occupancy Separation un- <br />less the building is equipped throughout with <br />an automatic fire -extinguishing system. Section <br />1102 (b). <br />56.` <br />I Light and ventilation should comply with Section <br />1105. <br />57. <br />Exhaust ventilation at or near floor lever is re- <br />quired by Section 1105. <br />58. <br />A One -Hour Fire -Resistive Occupancy Separation <br />is required between a boiler room or central <br />heating plant and the rest of the building. Sec. <br />lion 1108. <br />Group H <br />59. <br />A Group If Occupancy more than two Mories in <br />height or (raving more than 3000 square feet <br />above the first story should be of one -hour <br />fire -resistive construction throughout. Section <br />1302 (b). <br />GO. <br />Tile following rooms should have window areas <br />es specified in Section 1305 (a), one-half of <br />which is openable . <br />.............. ........ '.'-.-................................ <br />..............................-..---.-........................................... <br />Meanical ventilating system in bathroams <br />shchould provide live air changes per hour dl• <br />61. <br />racily to the outside. Section 1305 (a). <br />G2. <br />tYInflows from ......... ....... should <br />........................ . <br />not be considered as furnishing required light <br />or ventilation since they do not open to a yard, <br />court, or street in accordance with Section <br />1305 (a). <br />63. <br />Courts bounded an four sides will, walls should <br />be at least 10 feet in length. For courts more <br />than two stories In height, the required width <br />should be increased by ono loot and the re• <br />quired length by 2 feet for each additional <br />story, Section 130G (c). <br />Every sleeping room below the fourth floor <br />should have at least one window or exterior <br />door approved for emergency exit or rescue. <br />Section 1304. <br />65. <br />------•...............n*G"'.......------•... .......... room should <br />have the minimum ceiling height required in <br />Section 1307 (a). <br />66. <br />........................................................ room should <br />have a minimum superficial floor area of <br />.................... square feet. Section 1307 (b). <br />67. <br />Efficiency dwelling units should comply with <br />Section 1308. <br />68. <br />A One -Hour Fire -Resistive Occupancy Separation <br />Is required between a boiler room or central <br />heating plant and the rest of the building. <br />Section 1312. <br />69. <br />Every dwelling unit and guest room should have <br />comfort heating facilities as specified In Sec- <br />tion 1311- <br />Group J <br />70. <br />Group J Division 1 Occupancies are limited to <br />1000 (3000) square feet in floor area and one <br />story in height. Section 1502. <br />71. <br />Garages should not open directly into a room <br />used for sleeping purposes. .Section 1504. <br />72. <br />An approved noncombustible material or asphal• <br />tic paving material is required for garage floor <br />surfaces. Section 1504. <br />EXIT REQUIREMENTS <br />n occupant load sign is required in classrooms, <br />areas, etc., having an occupant load <br />jassembly <br />of more than 50. Section 3301 ()). See .......... <br />..................................................... . ................. <br />onforming exits are required from the areas <br />below as specified in Section 3302 (a), <br />.......................................................................... <br />......................................................................... <br />75. <br />Exits should have a minimum separation of one. <br />half lire maximum overall diagonal of the build. <br />Ing or area served. Section 3302 (c)............... <br />76. <br />No point in the building should be more than <br />150 (200) feet from an exterior exit, horizontal <br />exit, enclosed stairway, or exit passageway, <br />measured in the direction of travel. Section <br />3302(it). <br />77. <br />Exit door should swing in the direction of <br />egress. Section 5303 (b . ate doors <br />78.' <br />Double acting doors are not allowed when• sery <br />Ing a tributary occupant load of more than 100, <br />Section 3303 (b), <br />79.` <br />Exit doss should be operable from the inside <br />without the use of a key, special knowledge, or <br />effort. Section 3303 (c). Note also that flush <br />bolts or surface bolts are prohibited. <br />80. <br />Exit doors should be a minimum size of X x 6-0- <br />with a minimum door swing of 90 degmes, <br />• <br />Section 3303 (d). .............................................. <br />81.' <br />The net dimension (clear width) at doorways <br />should be used in determining exit widths <br />required by Section 3302 (b). Section 3303 <br />(d). In consideration of door thicknesses, panic <br />hardware, door swing, etc., the required exit <br />Widths have not been furnished. See door <br />