My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2715 HEWITT AVE TREND HAIR SOCIETY 2022-03-23
>
Address Records
>
HEWITT AVE
>
2715
>
TREND HAIR SOCIETY
>
2715 HEWITT AVE TREND HAIR SOCIETY 2022-03-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 2:39:28 PM
Creation date
8/17/2021 7:34:25 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2715
Tenant Name
TREND HAIR SOCIETY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Continuing with the previous comment, separate restrooms appear to be required per IBC <br />Section 2902.2. The occupant load appears to exceed 15 and does not comply with <br />Exception 2. <br />• Exception 2 not required. Occupancy does not exceed 15. See Occupancy <br />Calculations Table, Sheet 1 of 3. <br />• Both restrooms will be designated unisex. <br />7. Continuing with the previous comment, both restrooms are required to be accessible per <br />Chapter 11. <br />• Both restrooms are accessible per Chapter 11. Field measurements have been <br />taken, correct layout has been shown on Sheet 1 of 3, with details on Sheet 3 of 3. <br />8. The modified space is required to be accessible per IBC Chapter 11. Additional <br />dimensions or clarifications should be performed to verify. <br />• Facility is fully accessible. <br />• Front door is fully accessible. Proper clearance and automatic entrance and exit <br />openers are in place and functioning properly. <br />9. Accessibility improvements are required per EBC Section 705.2. Potential inaccessible <br />areas include the bathrooms and the main entrance. <br />• Facility is fully accessible. <br />i. Both bathrooms are fully accessible and will be designated unisex. <br />ii. The main entrance is fully accessible. <br />1. Front of building is structural stone. Cutting the exterior stone <br />to achieve 18" clearance on either side of the public entry is not <br />feasible. <br />• Will follow up on van accessible parking. It may not be feasible because of drive <br />through width encroachment. <br />i. Van accessible parking narrows the drive -through alleyway to 10' in <br />width, while the city appears to require 12' in width for commercial <br />properties. Unless there is a way to get a variance, this option is not <br />feasible. <br />10. The salon appears to include additional nail salon and other non -hair stations. Localized <br />exhaust ventilation may be required per the IMC. <br />• No nail salons are planned. All stations are hair related: Fair cutting station, <br />hair washing station, hair drying station. <br />RESPONSE TO ADDITIONAL NOTES OF March 1, 2021: <br />• The apparent accessible restroom, located towards the front of the space, has a door that <br />opens outward. This appears to comply with the accessibility requirements provided that <br />a door closer is not provided. If a closer is provided, then the door requires a minimum <br />clearance on the handle side of 12" to wall face. <br />• After field verification, the door swing was incorrect on the plans due to <br />conflicting photographic information. Customer has field verified March 1st, <br />2021 and I have corrected the drawings to show the actual door swing on <br />Sheet 1. Existing installation has a door closer and exceeds 12" handle <br />clearance requirements. <br />• The sinks should be provided with pipe protection. <br />
The URL can be used to link to this page
Your browser does not support the video tag.