6. Continuing with the previous comment, separate restrooms appear to be required per IBC <br />Section 2902.2. The occupant load appears to exceed 15 and does not comply with <br />Exception 2. <br />• Exception 2 not required. Occupancy does not exceed 15. See Occupancy <br />Calculations Table, Sheet 1 of 3. <br />• Both restrooms will be designated unisex. <br />7. Continuing with the previous comment, both restrooms are required to be accessible per <br />Chapter 11. <br />• Both restrooms are accessible per Chapter 11. Field measurements have been <br />taken, correct layout has been shown on Sheet 1 of 3, with details on Sheet 3 of 3. <br />8. The modified space is required to be accessible per IBC Chapter 11. Additional <br />dimensions or clarifications should be performed to verify. <br />• Facility is fully accessible. <br />• Front door is fully accessible. Proper clearance and automatic entrance and exit <br />openers are in place and functioning properly. <br />9. Accessibility improvements are required per EBC Section 705.2. Potential inaccessible <br />areas include the bathrooms and the main entrance. <br />• Facility is fully accessible. <br />i. Both bathrooms are fully accessible and will be designated unisex. <br />ii. The main entrance is fully accessible. <br />1. Front of building is structural stone. Cutting the exterior stone <br />to achieve 18" clearance on either side of the public entry is not <br />feasible. <br />• Will follow up on van accessible parking. It may not be feasible because of drive <br />through width encroachment. <br />i. Van accessible parking narrows the drive -through alleyway to 10' in <br />width, while the city appears to require 12' in width for commercial <br />properties. Unless there is a way to get a variance, this option is not <br />feasible. <br />10. The salon appears to include additional nail salon and other non -hair stations. Localized <br />exhaust ventilation may be required per the IMC. <br />• No nail salons are planned. All stations are hair related: Fair cutting station, <br />hair washing station, hair drying station. <br />RESPONSE TO ADDITIONAL NOTES OF March 1, 2021: <br />• The apparent accessible restroom, located towards the front of the space, has a door that <br />opens outward. This appears to comply with the accessibility requirements provided that <br />a door closer is not provided. If a closer is provided, then the door requires a minimum <br />clearance on the handle side of 12" to wall face. <br />• After field verification, the door swing was incorrect on the plans due to <br />conflicting photographic information. Customer has field verified March 1st, <br />2021 and I have corrected the drawings to show the actual door swing on <br />Sheet 1. Existing installation has a door closer and exceeds 12" handle <br />clearance requirements. <br />• The sinks should be provided with pipe protection. <br />