My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1212 CALIFORNIA ST RECOVERY CAFE EVERETT 2022-01-25
>
Address Records
>
CALIFORNIA ST
>
1212
>
RECOVERY CAFE EVERETT
>
1212 CALIFORNIA ST RECOVERY CAFE EVERETT 2022-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2022 9:32:06 AM
Creation date
8/18/2021 1:23:07 PM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
1212
Tenant Name
RECOVERY CAFE EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. John Hadley <br />EMA Investments, LLC <br />Plan Check Number: B1809-011, First Review <br />October 5, 2018 <br />Structural <br />1. The Partial Floor Plan on Sheet 1-of-2 specifies two new openings in the existing structural wall <br />at the northwest corner of the building. The following comments shall be addressed: <br />F, a. An analysis shall be performed evaluating the impact of the openings on the gravity and <br />lateral performance of the buildings. See IEBC Sections 807.4 and 807.5. <br />b. New structural elements required to construct the opening shall be designed per IEBC <br />Section 807.2. Framing members and details for connections shall be included in the <br />construction drawings. Calculations substantiating the design of the structural systems <br />shall be submitted for review. See IBC Sections 1603.1 and 1604.1. <br />2. Details for the connections of the walls to the floors at the bottom and top of the walls shall be <br />provided in the drawings. The connections shall be capable of resisting a 5 psf lateral force on <br />the walls. See IBC Section 1607.14. <br />This review has been performed for general compliance with the building codes as adopted and <br />amended by the state of Washington and the city of Everett. Corrections and comments made <br />during the review process do not relieve the project from compliance with code and permit <br />requirements. The designers -of -record are responsible for a complete design in accordance with <br />the laws of the state of Washington. <br />If you have any questions or require additional clarification, please contact us. <br />Respectfully, <br />Drew Martin, P.E., S.E. <br />Associate Engineer / Commercial Plans Examiner <br />(425)257-8813 <br />dmartin@everettwa.gov <br />S:\BMartin\2018\Bl8O9-011—Rl.docx <br />Pa�of <br />CITY OF EVERETT • 3200 Cedar Street . Everett, WA 98201 . (425) 257-8810 • Fax (425) 257- <br />
The URL can be used to link to this page
Your browser does not support the video tag.