My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1212 CALIFORNIA ST RECOVERY CAFE EVERETT 2022-01-25
>
Address Records
>
CALIFORNIA ST
>
1212
>
RECOVERY CAFE EVERETT
>
1212 CALIFORNIA ST RECOVERY CAFE EVERETT 2022-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2022 9:32:06 AM
Creation date
8/18/2021 1:23:07 PM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
1212
Tenant Name
RECOVERY CAFE EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. John Hadley <br />EMA Investments, LLC <br />Plan Check Number: B1809-011, First Review <br />December 12, 2018 <br />2-inch thick counter construction including subframe, and the 11-inch thick concrete <br />topping. The counter height exceeds the maximum 36-inch height for an accessible <br />service counter. The design shall be revised. The minimum required counter width shall <br />be 36 inches. See ICC Section 904.3.1. <br />e. The 51-inch tall partition wall exceeds the maximum side reach height of 48 inches. See <br />ICC A117.1 Section 308.3.1. <br />f. The depth of the counter shall be specified. The counter shall have a maximum depth <br />of 25 inches. See ICC A117.1 Section 308.2.2. <br />Structural <br />1. No additional comment. <br />2. This comment has not been completely addressed. The original comment stated that <br />details for the connections of the walls to the floors at the bottom and top of the walls shall <br />be provided in the drawings. The "Typical Partition" detail has been provided on Sheet 1-of- <br />2. The connections shall be capable of resisting a 5 psf lateral force on the walls. See IBC <br />Sections 107.2.1, 1603.1, and 1607.14. The following comments should be addressed: <br />a. The detail shows the top plate connection interrupted by a layer of GWB. The sill plate <br />should be fastened directly to the existing floor framing. <br />b. The detail should specify a sill plate connection to the existing slab -on -grade (SOG). <br />The connection shall account for the thickness of the new lightweight concrete topping <br />layer. The connection shall not penetrate the bottom surface of the SOG in order to <br />preserve the minimum required concrete cover per ACI 318-14 Table 20.6.1.3.1. <br />c. The detail only addresses the condition of walls running perpendicular to the existing <br />floor framing. A detail addressing the condition of walls running parallel to the wall, <br />particularly when the walls are located between the joists, should be included. <br />Additional Comments: <br />3. The Partial Floor Plan on Sheet 1-of-2 shows a new ramp at the west end of the General <br />Table Area. The ramp requires a handrail on the south side that appears to be mounted to <br />a partial height wall cantilevering from the SOG. Note that due to a thick topping slab, the <br />wall may actually be attached to this material. A detail shall be provided for the design of <br />the wall and its connection to the SOG. Calculations shall be submitted for review <br />substantiating the design of the wall and connections for the lateral loads specified in IBC <br />Section 1607.8.1. See IBC Sections 107.2.1, 1603.1, and 1604.1. <br />4. The northwest corner of the space has been revised to provide a bacony open to the <br />building exterior. The exterior walls shall be designed for wind loading per ASCE 7-10 <br />Chapter 30. The wall detail shall include connections of the top and bottom sills to the <br />floors. Calculations substantiating the wall and connections designs shall be submitted for <br />review. See IBC Sections 107.2.1, 1603.11 1604.1 and 1609.1. <br />5. The northwest corner of the space has been revised to provide a bacony with a guard. The <br />guard shall be designed for the loads per IBC Section 1607.8.1. Calculations for the design, <br />including the connections to the structure, shall be submitted for review. Details for the <br />3200 Cedar Street 425.257.8800 everettpw@everettwa.gov <br />�J Everett, WA 98201 425.257.8882 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.