Laserfiche WebLink
obtain a copy of the Ordinance and determine estimated charges prior to permit application. The <br />actual charges shall be computed by the Public Works reviewer per the ordinance in effect at the <br />time and according to the information on the approved plans at the time of permit issuance. Credit <br />will be given for any existing meters that are decommissioned as part of this development. <br />Supportive Housing credit in an amount up to 80% in accordance with Ordinance 3579-17 may be <br />applied for. To apply for this, please contact Becky Ableman McCrary at 425-257-7133 or <br />BAbl a ma n @ eve rettwa.aov. <br />14. An RPBA is required on the domestic service for premise protection on this site, and shall be located <br />in an above -ground hot -box if located outside of the building, or can be located in the sprinkler riser <br />room. <br />15. A DCDA is required on the fire service, and shall be located in a vault outside of the building if the <br />connection from the main to the building is greater than 70ft, or located in the sprinkler riser room <br />if within 70' of the connection to the main. <br />16. A DCVA is required on the irrigation service and shall be located in an underground vault <br />downstream of the meter. <br />17. The existing water main on Lombard Ave is a 12" cast iron main from 1956. Although this segment <br />of main does not have a history of breaks, 1946-1956 cast iron pipes do have a much higher break <br />frequency within the City. The landscape plans show planters and trees over or in close proximity to <br />the 12" cast iron main. These raised planter bed structures will not be allowed in the vicinity of the <br />main unless the development team chooses to relocate the 12" water main to the west in Lombard <br />Ave. <br />3 1 . The side sewer shall connect to the sanitary sewer main at a manhole if 20 units or more are served <br />by the side sewer. Verify the side sewer size is adequate for the number of units being served by <br />adding plumbing calculations per the 2015 UPC to the sewer plans. <br />1 Everett Transit requests a marked, ADA-accessible, load/unload zone large enough for a 22' <br />�.J paratransit bus, preferably as near to the entrance as possible. <br />20. This project is subject to Transportation Mitigation in accordance with Ordinance 3389-14 (codified <br />as EMC 18.40) and subsequent revision. Applicant is encouraged to obtain a copy of the Ordinance <br />and determine applicable mitigation fees and/or other requirements prior to building permit <br />application. The actual charges and requirements shall be as per the information on the approved <br />plans and an approved Traffic Study at the time of building permit issuance and the ordinance in <br />effect at that time. <br />21. Traffic Engineering accepts the TDM plan for the proposed development as submitted with the <br />following condition: <br />"Compass Health shall maintain a TDM coordinator whose contact information shall be provided <br />to the City of Everett. This person shall be responsible to ensuring implementation of the <br />approved TDM plan, If the TDM coordinator responsibilities are shifted to a different person, <br />then Compass Health shall notify the City of Everett of the new contact person promptly," <br />- age 7 of 1 <br />Project No. IiEVI - 15 <br />EVERETT <br />