My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 37TH ST Geotech Report 2018-01-02 MF Import
>
Address Records
>
37TH ST
>
1318
>
Geotech Report
>
1318 37TH ST Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:54:24 PM
Creation date
9/14/2021 7:40:30 AM
Metadata
Fields
Template:
Address Document
Street Name
37TH ST
Street Number
1318
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
James Pirie JN 97072 <br /> • March 1C. 1997 Page 5 I <br /> A o�ie-third increase in the above des:gn bearing pressures may be used when considering short- <br /> term wind or seismic loads. For the above design criteria, it is anticipated that the total post- <br /> construction settlement of footinos founded on competent, native soil, or on structurai fill up to 5 <br /> feet in thickness, will be about one-half inch, with differential settlements on the ordei of one-half <br /> inch in a distance of 50 feet along a continuous footing. <br /> Lateral loads due to wind or seismic forces may be resisted by friction between ihe foundation and <br /> the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the <br /> foundaiicn. For ine latter c.^.ndition, the foundation must be either poured directly against relatively <br /> level, undisturbed soil or surrounded by level, structural fill. We recommend using the following <br /> design value� for the foundation's reaistance to lateral loadin�: <br /> Parameter Desiqn Value <br /> Coefficient of Friction 0.45 <br /> Passive Earth Pressure 350 pcf <br /> Where: <br /> 1. pcf is pounds per cubic foot. <br /> ' 2. Passive earth pressure is computed <br /> using the equivalent fluid density. <br /> If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will <br /> not be appropriate. We recommend a safety factor of at least 1.5 for the foundaticn's resistance to <br /> lateral loading, when using the above design �alues. <br /> Seismic Consideratior�s <br /> The site is located within Seismic Zone 3, as illustrated on Figure No. 16-2 of the 1994 Uniform <br /> Building Code (UBC). In accordance with Table 16-J of the 1994 UBC, the site soil profile is best <br /> represented by Profile Type S2. The native soils tl�at underlie the site are not susceptible to <br /> seismic liquefaction. <br /> Slabs-on-Grade ' <br /> The building floors may be constructed as slabs-on-grade atop competent, native soils or structural <br /> fill. The subgrade soi� must be in a firm, non-yielding condition at the time of slab construction or <br /> underslab fi�l placement. Any soft areas encountered sheuld be excavated and replaced with <br /> select, imported, structural fill. <br /> All slabs-on-grade should be underiain by a capillary break or drainage layer consisting of a <br /> minimum 4-inch thickness of coarse, free-d�aining, siructural fill with a gradation similar to that <br /> discussed later in Permanent Foundation and Retainina WaII�. In areas where the passage of <br /> moisture through the slab is undesirable, a vapor barrier, such as a Gmil plastic membrane, should <br /> � <br /> �%o� <br /> G[OTGCHCONSULTANTS,IKC. <br />� <br />