Adk <br />01101116 <br />Lighting, Motor,and Libctrical Permit Checklist, ' <br />2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 <br />Project Title: SEA MAR EVERETT MEDICAL CLINIC <br />Date 6/18/2019 <br />The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />Applicability <br />ILocation <br />in <br />Building Department <br />(yes,no, na) <br />I Code Section <br />Component <br />Compliance information required in permit documents <br />Documents <br />Notes <br />LIGHTING CONTROLS <br />YES <br />C405.2 <br />Lighting controls, <br />For all lighting fixtures, indicate lighting control method on plans <br />A2.03 <br />general <br />for spaces and lighting zone(s) served, or exception taken <br />Luminaire level <br />Indicate on plans all fixtures provided with LLLC in lieu of <br />YES <br />C405.2 <br />lighting controls - <br />C405.2 lighting controls; provide description of control <br />A2.03 <br />(LLLC) <br />capabilities and performance parameters <br />For permanently installed lighting fixtures in dwelling units, <br />NA <br />C405.1 <br />Lighting in dwelling <br />indicate lighting control method on plans for spaces and <br />units <br />lighting zone(s) served, or demonstrate compliance with high <br />efficacy exception <br />C405.2.3 <br />Indicate on plans the method of manual lighting control (whether <br />C405.2.1.1 <br />combined with occupancy sensor, automatic light reduction, <br />YES <br />C405.2.2.2 <br />Manual controls <br />daylight responsive or specific application controls), location of <br />A2.03 <br />C405.2.4 <br />manual control device and area or specifice application it <br />C405.2.5 <br />serves <br />C405.2.2.1 <br />Manual interior <br />Indicate on plans which method of manual 50% lighting load <br />YES <br />C405.2.2.2 <br />lighting controls <br />reduction is provided, or whether lighting load is reduced via <br />A2.03 <br />C405.2.3 <br />occupancy sensors or daylight responsive controls <br />Indicate on plans the method of automatic shut-off control <br />during unoccupied periods (occupancy sensor or time switch) <br />A2.03 <br />Method of automatic <br />for all lighting zones; <br />YES <br />C405.2.2 <br />shut-off control <br />Indicate locations where automatic shutoff is provided by other <br />methods (occupancy sensor or digital timer switch) or which <br />time switch control exception applies <br />Indicate on plans the spaces served by occupancy sensors; <br />Indicate whether occupancy sensor controls are configured to <br />YES <br />C405.2.1 <br />Occupancy sensor <br />C405.2.1.1 <br />controls <br />be manual -on, automatic 50%-on, or serve a space eligible for <br />A2.03 <br />automatic 100%-on per exception <br />Occupancy sensor <br />Indicate aisleways and open areas in warehouse spaces <br />NA <br />C405.2.1.2 <br />controls - <br />provided with occupancy sensor controls that reduce lighting <br />warehouses <br />power by 50% <br />YES <br />C405.2.6 <br />Digital timer switch <br />Indicate required digital timer switch control function when <br />A2.03 <br />control is used <br />YES <br />C405.2.2.1 <br />Automatic time <br />Indicate locations of override switches on plans and the lighting <br />A2.03 <br />switch controls <br />zone(s) served, include area sq. ft. <br />Indicate primary and secondary sidelight daylight zone areas on <br />A2.03 <br />plans, include sq. ft.; <br />Indicate toplight daylight zone areas on plans, include sq. ft._ <br />AE2.01 <br />C405.2.4.2 <br />Daylight zones - <br />For small vertical fenestration assemblies (rough opening less <br />YES <br />C405.2.4.3 <br />Sidelight and toplight <br />than 10 percent of primary daylight zone) where daylight <br />responsive controls are not required, provide fenestration area <br />to daylight zone calculation(s) <br />Indicate on plans lighting zone(s) served by daylight responsive <br />A2.03 <br />controls; <br />Identify sidelight and toplight daylight zones that are not <br />provided with daylight sensing controls and the exception(s) that <br />AE2.01 <br />YES <br />C405.2.4 <br />Daylight responsive <br />apply; <br />Indicate on plans the lighting load reduction method - <br />controls <br />continuous dimming, or stepped dimming that provides at least <br />two even steps between 0%-100% of rated power; <br />Indicate that daylight sensing controls are configured to <br />completely shut off all controlled lights in the lighting zone <br />Additional controls - <br />Identify spaces and lighting fixtures on plans that require <br />YES <br />C405.2.5 <br />Specific application <br />specific application lighting controls per this section <br />AE2.01 <br />lighting controls <br />Indicate on plans that display and accent lighting, and display <br />C405.2.5 - <br />Display and accent <br />case lighting are controlled independently from both general <br />A2.03 <br />YES <br />Items 1&2 <br />lighting <br />area lighting and other lighting applications within the same <br />space; <br />Indicate manual and automatic lighting control method <br />