My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6815 COLBY AVE 2022-01-27
>
Address Records
>
COLBY AVE
>
6815
>
6815 COLBY AVE 2022-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2022 12:04:12 PM
Creation date
10/14/2021 10:50:44 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
6815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Kevin and Stacey Cole <br />6815 Colby Avenue <br />Plan Check Number: B2005-038, First Building Review <br />July 1, 2020 <br />5. Section 1/A303 should specify a continuous #4 reinforcing bar at the top and bottom of the <br />foundation. The bars should be specified as minimum Fy=40ksi steel. The section should <br />specify a minimum cover of 3 inches. See IRC Sections R403.1.3.3, R403.1.3.5.1, and <br />R403.1.3.5.3. <br />6. Section 1/A303 should specify minimum 1/2-inch bolts with a minimum 7-inch embedment per <br />IRC Section R403.1.6. The bolt spacing should not exceed 6 feet, and provide at least two bolts <br />in each wall panel section located not more than 12 inches from the end of the sill plates. The <br />bolts should include 3-inch washers per Sections R403.1.6.1(1) and R602.11.1. Anchor <br />hardware should specify corrosion protection per Section R317.3.1. <br />Walls: <br />7. Section 1/A303 specifies use of pressure -treated sill plates for the walls. The following <br />comment should be addressed: <br />a. The section specifies a minimum clearance of 6 inches. However, the section and West <br />Elevation 2/A204 indicate the clearance may be less than 6 inches, placing the vertical wall <br />framing, sheathing, and siding less than the minimum clearance to exposed ground. Note <br />that the existing grade slopes towards the west side of the building per Site Plan 1/A000, <br />and foundation drains are not provided, which may result in the accumulation of sediment <br />and water. The minimum clearance should be provided or the wall construction should use <br />preservative -treated or naturally -durable wood. See IRC Section R317.1(5). <br />b. South Elevation 1/A204 and Section 1/A304 indicate that the wall framing will be level with <br />the driveway slab -on -grade. The vertical wall framing, sheathing, and siding are within the <br />minimum 2-inch clearance. The minimum clearance should be provided or the wall <br />construction should use preservative -treated or naturally -durable wood. See IRC Section <br />R317.1(5). <br />c. Cut ends of preservative -treated wood should be coated with a preservative treatment <br />complying with AWPA M4. The requirement should be stated in the construction drawings. <br />See IRC Section R317.1.1. <br />8. Section 1/A303 specifies a wall assembly that is presumed typical for the entire building. The <br />following comments should be addressed: <br />a. The design is presumed to comply with the continuous sheathing method of IRC Section <br />R602.10.7. The drawings should specify this as the typical construction, or the braced wall <br />lines on each side of the building should be designated. See IRC Sections R106.1.1, <br />R602.10.1, and R602.10.7. <br />b. The wall assembly should specify the required fasteners between the sheathing and <br />framing. See IRC Section R602.10.4 and Table R602.10.4. <br />c. The wall pier on Plan 1/A104 between the door and building corner on the west side should <br />be increased to a minimum of 24 inches per IRC Figure 602.10.7(Condition 4). <br />O3200 Cedar Street 425.257.8810 everetteps@everettwa.gov <br />Everett, WA 98201 425.257.8857 fax everettwa.gov/perm4s <br />EPage34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.