My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• May 23, 2018 <br /> Mr.Tony Lee <br /> Snohomish County Courthouse Renovation/Addition <br /> Page <br /> 4) It should be clarified if the existing building is currently provided with an emergency <br /> voice/alarm communication system as specified in Section 907.2.1.1. <br /> Response:Per earlier agreement with the City, new fire alarm system with voice/alarm <br /> annunciation will be provided in areas of the existing building that are being <br /> renovated/remodeled. Existing areas that are not being renovated/remodeled will not be <br /> upgraded to the new fire alarm system. The existing fire alarm system devices are to <br /> remain. The existing system will report to the new system. The existing system is not a <br /> voice communication system. <br /> 5) Wainscoting should be shown for the toilet rooms in elevations 17 & 18 on Sheet IQ-201. <br /> Section 1210.2.2 <br /> Response: Wainscoting is not required based on Exception #2. These toilet rooms do not <br /> have more than one water closet and are not accessible to the public. <br /> Construction <br /> 1) Listings for both the TGP Firelight Plus and Tyco sprinkler assemblies should be provided. <br /> The specific proposed product should be shown to be within the listing specifications for <br /> the proposed use and minimum fire-rating per code.Section 716.2 <br /> Response: The individual listings for each product are attached along with the Data Sheet <br /> on the use of these two products used together as an Alternate Means of Compliance in <br /> accordance with IBC 104.11. <br /> 2) A listing for WON doors should be provided. Section 703.2 <br /> Response:The listing for the Won-Door is attached. <br /> 3) Fire resistive listings and assembly details should be provided for the steel columns, <br /> beams, roof/ceiling and floor/ceiling assemblies.Sections 703.1& 704.1 <br /> a. Special inspection requirements should be noted on the plans for the sprayed fire- <br /> resistant materials. Section 1705.4 <br /> Response: UL assemblies have been included in the 100% CD set. Spray-on fireproofing is <br /> indicated on sheet GV-204. Intumescent coating is indicated on sheet GV-205. The roof <br /> assembly is indicated on sheet GV-205. The floor/ceiling assembly is indicated on sheet <br /> GV-204. <br /> 11111 <br />
The URL can be used to link to this page
Your browser does not support the video tag.