My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• May 23, 2018 <br /> Mr.Tony Lee <br /> Snohomish County Courthouse Renovation/Addition <br /> Page -r< <br /> 4) If the steel columns in Details 15& 16 on Sheet A-503 and 2 on Sheet A-502 are part of <br /> the structural frame,they will need to be provided with fire resistive protection. Sections <br /> 704.2&602.1 <br /> Response:Detail 15 on sheet A-503 and Detail 2 on sheet A-502 have been revised to <br /> show 2-HR intumescent coating on the steel framing. Detail 16 is for a screen wall on the <br /> roof. It has not been revised. <br /> 5) The listing for the two-hour,fire resistive GWB cover around the steel column within the <br /> wall shown in Detail 9 on sheet A-503 should be shown on the plans(and any similar). <br /> Section 704.2 <br /> Response: This detail has been revised. However, the UL Assembly number has been <br /> added to Partition type "N"on sheet 1-321 as indicated in comment#6 and not to detail 9 <br /> on sheet A-503. <br /> 6) Two-hour partition Type N on Sheet 1-321 should have a listing provided on the detail. <br /> • Section 703.1 <br /> Response:A UL assembly number has been added to this partition type on sheet 1-321. <br /> 7) It is not apparent why doors 4620 and 4600B are 90-minute rated as shown on the door <br /> schedule. <br /> Response: The ratings for these doors has been removed in the 100% CD set. <br /> 8) The elevator machine room door is rated however the(southern)wall it is in is not rated: <br /> section 3005.4 would not appear to require a fire-resistive separation. <br /> Response:A 2-hour fire rated partition tag has been added to plan detail 1 on sheet 1-410. <br /> 9) The plywood in partition type 3 on Sheet I-322 should be shown as FRT as it represents a <br /> building element from Table 601 that is required to be non-combustible(non-rated)and is <br /> also not blocking within the wall cavity(but the wall itself). Exceptions 1.1 and 14 to <br /> Section 603.1 <br /> Response: This detail has been deleted in the 100%CD set. <br /> 10)A listing should be provided that shows the proposed fire-stopping at the curtain walls has <br /> been tested in accordance with ASTM E 2307 and provides a minimum two-hour F rating. <br /> Section 715.4 <br /> Response:A UL assembly has been included on sheet GV-204 in the 100% CD set. <br /> Additional information regarding the testing has been included with this letter. <br />
The URL can be used to link to this page
Your browser does not support the video tag.