My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• May 23, 2018 <br /> Mr.Tony Lee <br /> Snohomish County Courthouse Renovation/Addition <br /> Page <br /> 11)The glazing separating the entry lobby and the exterior landing of the new stairway(ST-1 <br /> first floor) is part of the stair enclosure and should be shown protected for minimum two- <br /> hour,fire resistive construction.Section 1023.2 <br /> Response:A 2-hour rating tape is indicated for this glass on sheet GV-101. The glass for <br /> the curtainwall frame is indicated to be FG-1(Fire Rated Clear Glass)in curtainwall frame <br /> C05 indicated on sheet A-701. <br /> 12)The exterior wall along construction line 18.1 that is 90 degrees to stairs ST-1 should be <br /> shown as minimum one-hour construction (with 3/4 hour opening protection) on each floor <br /> (currently only 2nd floor specified)for a minimum distance of 10 feet from the stairs. <br /> Section 1023.7 <br /> Response: The curtainwall has been removed and replaced with a fire rated partition on <br /> Levels 3-5 on the north wall of Stair ST-1. <br /> Accessibility <br /> • 1) It should be shown that Doors 4621E&5500E have a minimum of 18" clear on the pull <br /> side.ANSI Section 404.2.3 <br /> Response:These 2 doors have been shifted west to accommodate the ADA clearance. <br /> 2) It should be shown that the toilet partitions that have grab bars attached to them are able <br /> to support the additional 250#concentrated load as required by Section 1607.8.2 <br /> Response: This requirement is stated in the Metal Toilet Compartments specification <br /> section 102113.13,paragraph 2.2.D.2. The toilet compartment manufacturer must <br /> comply with this requirement. <br /> 3) The bottom edge of the vision lites in the doors shown on Sheet 1-610 should be shown no <br /> higher than 43 inches maximum above the floor.ANSI 404.2.10 <br /> Response: The bottom edges of these doors have been revised on sheet 1-610. <br /> Energy <br /> 1) Energy code compliance sheets for the envelope, lighting(interior and exterior)and <br /> mechanical systems should be provided for review. <br /> Response: The lighting compliance forms have been completed and attached to this letter. <br /> There are changes to the lighting plans which are also included. The mechanical energy <br /> code compliance form is shown on Sheet M-002. <br /> • <br />
The URL can be used to link to this page
Your browser does not support the video tag.