My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Mark Thunberg <br />Snohomish County Property Management <br />Plan Check Number: B1802-011, First Review (Structural) <br />June 18, 2018 <br />5. Section 1.2.2 "Materials — Concrete" states that the design is based on light -weight concrete in <br />the composite decks. The "Concrete", "Composite Floor System", and "Steel Composite Deck" <br />sections of the General Notes on Sheet S-002 do not appear to specify light -weight concrete. <br />The notes should be reviewed and revised as needed. See IBC Section 107.2.1. <br />6. Section 2.1 "Materials" of the structural calculations states that the design of the lateral system <br />(i.e., concrete shear walls) is based on concrete strength of f'C=7,000 psi. The "Concrete" <br />section of the General Notes on Sheet S-002 states a strength of 6,000 psi. The structural <br />notes should be revised. See IBC Section 1901.5 Item 1. <br />7. Section 2.1 "Materials" of the structural calculations state that the reinforcing steel for the <br />"ties" shall be ASTM A706 Grade 80. The "Reinforcing Steel" section of the General Notes on <br />Sheet 5-002 specifies ASTM A615 Grade 60 reinforcement unless otherwise noted. The <br />"Special Ductile Quality Reinforcing Steel" section specifies A706 reinforcement, but does not <br />specify Grade 80. The concrete shear wall design on Sheets S-301 through S-311 does not <br />appear to specify Grade 80 reinforcement. The reinforcement qualifying as "ties" should be <br />clarified. The drawings should be revised to specify ASTM A706 Grade 80 reinforcement where <br />required. See IBC Section 1901.5 Item 2. <br />8. The "Reinforcing Steel" section of the General Notes on Sheet S-002 states that welding of <br />reinforcing bars is prohibited except where approved by the engineer. However, the drawings <br />specify welding in multiple locations including connections between collectors and concrete <br />shear walls. See Details 16/S-601 and 17/5-603 as examples. The note should be revised for <br />consistency with the drawings. The note should require that all welded reinforcement be ASTM <br />Grade A706 unless use of an alternate material is approved by the engineer. The note shall <br />require a mill test report for reinforcing bars not complying with ASTM A706 to verity <br />weldability. See IBC Section 1901.2 and ACI 318-14 Section 26.6.4.1(a). <br />9. Sheet 5-201 includes a 13'-6" dimension near Grid J/19.1 that appears intended to locate a <br />footing and column at Grid H.6/19.1. However, the dimension does not align with the footing <br />and column, and does not appear to correspond to any other structural elements. The <br />dimension should be revised and revised as needed. See IBC Section 1603.1. <br />10. Detail 17/5-603 shows a drag connection with (3) #6 bars connecting to an embedded angle. <br />The detail does not appear to specify a connection between the bars and angle. The detail <br />should be reviewed and revised as needed. See IBC Section 107.2.1. <br />11. The locations of the braced frames in Partial Plan 14/S-251 appears to be incorrect. The <br />frames appear intended to occur on grid lines per Partial Plan 19/S-251. In addition, the <br />Section 15/5-321 reference appears mislocated. The plan should be revised. See IBC Section <br />1603.1. <br />Page 3 of 11 <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 . Fax (425) 257-885 <br />
The URL can be used to link to this page
Your browser does not support the video tag.