My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
ADMIN BLDG WEST
>
3000 ROCKEFELLER AVE ADMIN BLDG WEST 2022-05-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 10:40:58 AM
Creation date
10/15/2021 9:33:59 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
ADMIN BLDG WEST
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
524
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Mark Thunberg <br />Snohomish County Property Management <br />Plan Check Number: B1802-011, First Review (Structural) <br />June 18, 2018 <br />Foundation System: <br />12. The design for the shear wall foundations is provided in Section 4.2 of the structural <br />calculations. The calculations appear substantially incomplete. Additional documentation <br />substantiating the design should be submitted for review. The additional documentation <br />should include but is not limited to: input modeling criteria including material strengths and <br />cracked section properties; complete loading criteria for all footings; documentation of load <br />combinations including vertical seismic effects per ASCE 7-10 Section 12.4.2.2; calculations for <br />the shear and flexural design of the footings. See IBC Sections 1604.1, 1604.4, and 1613.1. <br />13. The "Location B" footing appears to respresent the foundation at Grid 1.5-K/12.1-13.1. The <br />size of the footing in the calculations appears inconsistent the drawings. At a minimum, the <br />south side of the footing appears to extend significantly farther than shown in the drawings. <br />The design of the footing should be reviewed and revised as needed. See IBC Section 1604.4. <br />14. The shear wall foundation at Grid C/8-11 includes micropiles at each end. The embedment of <br />the piles into the foundation is shown in Sections 10/S-502 and 15/S-502. The following <br />comments should be addressed: <br />a. Sheet S-200 specifies that the piles shall be cored through the existing footings. This <br />should be shown in one of the sections. See IBC Sections 107.2.1. <br />b. Calculations substantiating the capacity of the piles should be submitted for review. See <br />IBC Section 1604.1. <br />c. The sections show the piles embedding for most of the foundation depth. The piles do not <br />appear to include supplemental reinforcement connecting them to the foundation. <br />Calculations substantiating the load transfer to the piles for compression and uplift should <br />be submitted for review. See IBC Sections 1604.1 and 1604.4. <br />15. Additional documentation for the design of the shear wall foundation at Grid C/8-11 should be <br />submitted for review. See IBC Section 1604.4. The following comments should be addressed: <br />a. The foundation appears to be designed as a monolithic element. However, the foundation <br />encases three existing gravity footings. The foundation should be evaluated considering its <br />actual geometry, including discontinuities in its structure. <br />b. The foundation is anticipated to have rigid bearing zones at the ends due to the micropiles. <br />The foundation shall be designed as needed by analysis to span between the ends and <br />distribute vertical loads to the piles. <br />c. The load path between the shear wall and the continuous sides of the foundation shall be <br />substantiated. <br />Gravity System: <br />16. Section 1.2.3 provides gravity loading criteria for the gravity system analysis. See IBC Sections <br />1604.4, 1606, and 1607. The following comments should be addressed: <br />a. Level 02 includes an opening and framing for a stairway at Grid 3-K/12.1-13.1 that is not <br />included in the model. The framing plan should be revised and the design verified. <br />b. The second and fourth floors indicate a live load of 80 psf. The areas carry significant <br />areas of 100 psf live load for assembly loading per Sheets 5-102 and S-103. The analysis <br />appears based on use of an average value, which is not appropriate as some framing <br />age 4 of 11 <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.