My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 SE EVERETT MALL WAY AEROTEK 2021-11-02
>
Address Records
>
SE EVERETT MALL WAY
>
1010
>
AEROTEK
>
1010 SE EVERETT MALL WAY AEROTEK 2021-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2021 1:10:06 PM
Creation date
11/2/2021 1:09:15 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1010
Tenant Name
AEROTEK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Egress: <br /> 5. The common path of egress travel to the exterior exits exceeds 75 feet for Room 11 and the adjacent rooms, with <br /> the longest paths occurring for Rooms 13 and 16. Two exits are required. The maximum exit access travel distance <br /> for an unsprinklered 8-occupancy building is 200 feet. The second route for both Rooms 13 and 16 exceeds the <br /> travel distance. Note that the route through the Reception Room 01 is not valid as a second path where the first <br /> path travels through Door 11A. The egress paths shall be revised. See IBC Tables 1006.2.1 and 1017.2,and IEBC <br /> Section 801.3. <br /> Response: Our understanding of the code is that the common path of egress is the maximum <br /> distance an occupant can travel before having two different exit path options,this is true for the exit <br /> path from both Room 13 and Room 16.According to the 2015 International Code Commentary the <br /> "common path of travel stops when the occupant has a choice of at least two exits, and overall travel <br /> distance stops when an occupant gets to the closest exit"(see attached page). Our understanding of <br /> the maximum travel distance is that it is only applied to the nearest exit. In our case both Room 13 <br /> and 16 are within 200'from their nearest exit. In the case of the travel path exiting to the south the <br /> side lobby is a rated exit enclosure, so the travel distance stops the doors leading to it.The diagram <br /> has been revised to more clearly show our interpretation of the code sections. We have also included <br /> the relevant section from the 2015 ICC Code Commentary with highlighted excerpts to support our <br /> methods attached to this letter. <br /> 6. The Occupancy and Exiting Diagram on Sheet A0.02 shall specify additional exit signs. Exit signs shall be provided <br /> at the following locations:north and south ends of Room 11,Door 018,Main Lobby exterior doors,Corridor south <br /> of the Main Lobby,hallway outside Interview Room 06, and the interior and exterior double doors at the south <br /> Lobby. Where existing exit signs occur, these shall be indicated on the plans. Intermediate exit signs shall include <br /> direction arrows where door signs are not readily visible. The lighting,including existing locations,shall specify a <br /> minimum 90-minute uninterrupted supply power per IBC Section 1013.6.3. See IBC Section 1013.1 and IEBC Section <br /> 801.3. <br /> Response: Exit signs have been added at the locations mentioned in your comment and a note <br /> regarding exit sign illumination power supply has been added on sheet A6.01. <br /> 7. Means of egress illumination shall be provided per IBC Section 1008. The lighting shall specify a minimum 90- <br /> minute uninterrupted supply power per IBC Section 1008.3.4. Where existing systems occur, they shall be indicated <br /> on the plans. See IEBC Section 801.3. <br /> Response: A note regarding egress illumination has been added on sheet A6.01. <br /> 8. The exterior landings for doorways serving an occupant load of 50 or more shall be provided with emergency <br /> lighting. The lighting shall specify a minimum 90-minute uninterrupted supply power per IBC Section 1008.3.4. See <br /> IBC Sections 1008.3.2 Item 5 and 1010.1.6. Where existing systems occur,they shall be indicated on the plans. See <br /> IEBC Section 801.3. <br /> Response: A note regarding emergency lighting at exterior landing for doorways has been added on <br /> sheet A6.01. <br /> 9. The Site Plan on Sheet A1.00 appears to show modifications to the existing sidewalk on the north side of the <br /> building. See IBC Sections 107.2.1 and 1102.1. The following comments shall be addressed: <br /> a. The extent of the modifications is not clear and shall be clarified on the site plan. Details for the sidewalk <br /> modifications should be provided. <br /> Response: Please see A1.00 for revised drawings and notes describing the work. The <br /> approach for accessibility for the parking lot has been modified to use curb cuts at each access aisle <br /> instead of the sloped walkway. <br /> b. The slopes and cross-slopes shall be specified in the drawings. See IBC Sections 1012.2 and 1012.3,and <br /> ICC A117.1-09 Sections 405.2 and 405.3. <br /> Response: Please detail 2/A1.00 describing the requirements for the curb cuts at each <br /> access aisle. <br /> c. The ramps shall specify a slip-resistant surface per IBC Section 1012.7.1. <br /> Response: See detail 2/A1.00 for curb cuts detail and call outs. <br /> d. Ramps with a rise exceeding 6 inches shall be provided with handrails per IBC Section 1012.8. <br /> Response: Because the sloped walkways have been removed and replaced with curb <br /> cuts this comment no longer applies. <br /> Project#B1903-041 — 1010 SE Everett Mall Way <br /> In <br />