My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
14 E CASINO RD CHILD STRIVE 2022-01-14
>
Address Records
>
E CASINO RD
>
14
>
CHILD STRIVE
>
14 E CASINO RD CHILD STRIVE 2022-01-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2022 7:28:44 AM
Creation date
11/9/2021 11:11:44 AM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
14
Tenant Name
CHILD STRIVE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Markus Barrera-Kolb <br />Environmental Works <br />Plan Check Number: B1903-001, Second Building Review <br />May 20, 2019 <br />Architectural <br />General: <br />1. No additional comment. <br />2. No additional comment. <br />3. No additional comment. <br />Egress: <br />4. No additional comment. <br />This comment has not bene completely addressed. The original comment addressed panic <br />hardware and swing directions for exiting doors. The following comments should be addressed: <br />a. Door 104a required panic hardware per the original comment. The Interior Door Schedule <br />on Sheet A2.2 has not been revised. Note that the schedule does specify hardware for Door <br />108a, but this door is not specified in the Floor Plan on Sheet A2.1. The drawings should <br />clarify is these are the same door and be revised as needed. <br />b. The Floor Plan on Sheet A2.2 specifies the new Door 104a into Room 108 with an inward <br />swing. All new doors shall swing in the direction of egress travel. See IBC Section <br />1010.1.2.1. Note that only a single door is required at this location. <br />c. Door 105a appears in the Interior Door Schedule on Sheet A2.2, but is not specified in the <br />Floor Plan on Sheet A2.1. The drawings should be revised as needed. <br />d. The Floor Plan on Sheet A2.1 shall specify a maximum occupant load sign for Room 108 <br />near the main exit. See IBC Section 1004.3. <br />6. This comment has not been completely addressed. The original comment addressed the <br />occupant load and egress requirements for Rooms 100 through 103. The response revised the <br />occupant load for this area below the limit requiring two exits. Sheet T1.2 specifies a second <br />exit through Room 105, and Sheet A2.1 specifies an exit sign at the interior door for this room. <br />The exit is not required, and exiting through this room is not permitted; the sign should be <br />removed. See IBC Section 1016.2 Item 2. <br />7. This comment has not been completely addressed. The original comment stated that <br />intermediate exit signs shall be provided where door signs are not readily visible. A sign shall <br />be provided in the Floor Plan on Sheet A2.1 near the Staff Desk. The sign shall be viewable <br />from Hallway 107 and provide an arrow pointing towards Door 100. Note that the sign <br />indicated near Door 115a is not required. See IBC Section 1013.1. <br />8. This comment has not been completely addressed. The original comment stated that means - <br />of -egress illumination shall be provided per IBC Section 1008, and shall specify a minimum 90- <br />minute uninterrupted supply power per IBC Section 1008.3.4. Notes have been added to Sheet <br />T1.2 in response. However, this is not sufficient to indicate where the lighting must be <br />provided. A ceiling plan shall be provided specifying the egress lighting locations. See IBC <br />Section 107.2.1. <br />M) 3200 Cedar Street 425.257.8810,E everetteps@everettwa.gov <br />Everett, WA 98201 425.257.8857 fax eeverettwa.gov/ ermits <br />Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.