Laserfiche WebLink
0 M <br />Permit Corrections: 14 E Casino Road <br />June 6, 2019 <br />Page 2 of 5 <br />Sheet A2.1: Door 108a had been mislabeled; it is now correctly identified on the floor plan <br />and is now shown as a bi-parting door with both panels swinging in the path of egress <br />travel. The provision of panic hardware at this door has been added to the Interior Door <br />Schedule, Sheet A2.2. <br />Sheet A2.1: The missing ID tag for Door 105a has been added to the floor plan. <br />Sheet A2.1: Keynotes have been added at doors 108-1 and 108-2 requiring maximum <br />occupancy signs for both halves of the multipurpose room. <br />6. Exiting through room 105: <br />This comment has not been completely addressed. The original comment addressed the <br />occupant load and egress requirements for Rooms 100 through 103. The response revised <br />the occupant load for this area below the limit requiring two exits. Sheet T1.2 specifies a <br />second exit through Room 105, and Sheet A2.1 specifies an exit sign at the interior door for <br />this room. The exit is not required, and exiting through this room is not permitted, the sign <br />should be removed. See IBC Section 1016.2 Item 2. <br />Environmental Works maintains that, per IBC 1006.2.1, Number of Exits and Exit Access <br />Doorways, the cumulative load in the lobby area, exceeding 49 occupants, requires two <br />exits, and that per IBC 1016.2, Egress Through Intervening Spaces, an egress path through <br />Meeting Room 105 is code compliant. Please see attached email correspondence with <br />code and code commentary excerpts, included per your request. <br />7. Intermediate exit signs: <br />This comment has not been completely addressed. The original comment stated that <br />intermediate exit signs shall be provided where door signs are not readily visible. A sign <br />shall be provided in the Floor Plan on Sheet A2.1 near the Staff Desk. The sign shall be <br />viewable from Hallway 107 and provide an arrow pointing towards Door 100. Note that the <br />sign indicated near Door 115a is not required. See IBC Section 1013.1. <br />Sheet A2.1: The keynote indicating directional egress signage at Door 115a has been <br />removed and a new keynote has been added on the wall above the reception desk, visible <br />from Hall 107, and pointing south toward egress/entry Door 100. <br />8. Egress lighting locations: <br />This comment has not been completely addressed. The original comment stated that <br />means -of -egress illumination shall be provided per IBC Section 1008, and shall specify a <br />minimum 90-minute uninterrupted supply power per IBC Section 1008.3.4. Notes have <br />been added to Sheet T1.2 in response. However, this is not sufficient to indicate where the <br />lighting must be provided. A ceiling plan shall be provided specifying the egress lighting <br />locations. See IBC Section 107.2.1. <br />Sheet A2.1: A symbol for emergency egress lighting has been added to the Floor Plan <br />Legend, Sheet A2.1, and proposed locations for both interior egress lighting fixtures as well <br />as exterior emergency lighting fixtures with 90 minute emergency power per IBC 1008 have <br />been indicated on the floor plan. We hope this will adequately communicate proposed <br />locations of emergency egress lighting, instead of providing a Reflected Ceiling Plan. <br />