• <br />August 8, 2019 <br />EVERETT <br />WASHINGTON Owner: Vander Veen <br />Job Address: 5411 Ocean Dr. <br />Plan Check No: C1907-005 <br />ov , 04N <br />/N G4.•4c.-jl— <br />RE: Building Permit Review Letter <br />Dear Mr. Vander Veen, <br />In response to the application for a building permit, the plans have been <br />examined and you are advised that revisions are necessary before a permit can <br />be issued. Please review and respond to the comments below. <br />The foundation plan on sheet S1.0 does not match the floor plan on Sheet <br />2.0. The dimensions are different for the location of additions and for the <br />existing structure. <br />2. The foundation plan shows new construction as existing. Please correct. <br />Provide detail for the connection of the new foundation to the existing <br />foundation. <br />The area of floor used for parking of automobiles or other vehicles shall <br />be sloped to facilitate the movement of liquids to a drain or toward the main <br />vehicle entry doorway. Show requirement on the plans. <br />Provide 6 mil black vapor barrier in crawl space with edges lapped <br />minimum 12 inches. Show requirement on plans. <br />Provide minimum 18" x 24" crawl space access. Show location on <br />foundation plan. If access opening is in the floor, show the location on the main <br />floor plan. <br />Tan <br />Provide note on drawings "Minimum %2" x 10" anchor bolts at not more <br />48 inches on center with minimum 7 inch embedment. Minimum 2 each <br />piece and within 12 inches of each end of each piece. Minimum 3" x 3" x %" plate <br />washer on all anchor bolts". <br />Stub -out #4 rebar at maximum 18" O.C. at all concrete landings at <br />terior entrance/exits. Show location of landings and reinforcing steel on <br />foundation plan. <br />Specify on plans at exterior entrance/exits, landings are required to be <br />',7ai7t _ ot more than 7-3/4" below the finished floor. <br />LC_T1 vG r t� D� 10. Provide minimum 5/8-inch Type "X" GWB on the ceiling in the garage <br />PUBLIC WORKS nd on the underside of the stairs that are accessible from the garage, -and <br />r( v*- P� 4 igN p minimum %:" GWB on all walls supporting a living space above the garage. Show <br />Q32 0 Cedar Street on the plans. <br />Everett, WA 98201 ,�-�� <br />L� The Second Floor Framing Plan does not include an opening for the <br />425.257.8800 stairs. Show all framing for the opening and show how gravity loads are <br />425.257.8882 fax transferred to the foundation. tt'_tz pc v 3 r 6 PLv g8' <br />12 Provide stair section and/or detail(s). Specify construction including <br />everettww@everettwa.gov everettwa.govlpw stringer attachment to the landing and floor joists and the framing of the landing. <br />13. Provide building section drawing(s) and/or details specific to this <br />structure. All section drawings shall identify and dimension all components. <br />