My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5411 OCEAN AVE 2022-02-24
>
Address Records
>
OCEAN AVE
>
5411
>
5411 OCEAN AVE 2022-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 4:03:38 PM
Creation date
11/9/2021 2:59:34 PM
Metadata
Fields
Template:
Address Document
Street Name
OCEAN AVE
Street Number
5411
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:7 <br />0 <br />Show each different type of construction in a section and/or detail drawing including but not limited <br />to; <br />The covered porches including all connections and construction <br />—, The floor framing that extends into the existing garage <br />The deck over the Family Room Addition <br />d. Guard construction and connection to the structure <br />e he connection of the proposed slab -on -grade to the existing concrete slab in the gara e <br />A' edger attachment to the foundation (existing and proposed) ---r ,+ ✓i o <br />RA wall section for full height framing adjacent to the stairs <br />A foundation section showing the depth and width of footings and stem walls <br />and the minimum depth.below and above grade. <br />�he roof over the 16' wide garage door <br />'Provide smoke alarm per section. R314 in Bedroom #1 on the Main Floor and provide a Smoke alarm <br />and Carbon Monoxide alarm outside of the bedroom on the main floor per sections R314 and R315 <br />IRC 2015 ed. <br />15 Provide calculations for stud walls over 10 feet in height supporting a roof and/or floor load (adjacent <br />to stairs). Provide detail of construction at 2-story wall. <br />16. Specify the size of the whole house fan based on Tables M1507.3.3(1) (continuous operation) and/or <br />M1507.3.3(2) (intermittent operation). <br />17. All Braced Wall Lines (R610.2 IRC) and braced wall panels shall be clearly marked on the plans. <br />In order for the processing of your application to continue, it will be necessary to provide the Building <br />Division with two new sets of revised construction documents reflecting the corrections requested. <br />Please include a response letter which indicates how the corrections were resolved. <br />All codes cited refer to the 2015 International Building Code (IBC), 2015 International Residential Code <br />(IRC), and/or the 2015 Washington State Residential Energy Code (WSEQ as amended by the State of <br />Washington and adopted by the City of Everett. <br />These comments address building issues only. Additional revisions or additions may be required by other <br />departments (such as Utilities, Traffic, Planning or Fire). All required submittals must be of sufficient detail <br />and information to ensure that the proposed structure will be constructed in compliance with all adopted <br />codes. <br />Provide a response letter showing where all corrections are addressed on the revised plans. <br />Sincerely <br />Jeff Heil an <br />Development Technician <br />City of EverettPublicWorks Department <br />3200 Cedar St, Everett, WA 98201 <br />Office: 425-257-8810 J Direct: 425-257-8976 <br />Page 2 of 3 <br />P4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.