My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1122 75TH ST SW PUD STORAGE 2021-12-28
>
Address Records
>
75TH ST SW
>
1122
>
PUD STORAGE
>
1122 75TH ST SW PUD STORAGE 2021-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 12:41:00 PM
Creation date
11/10/2021 10:59:43 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1122
Tenant Name
PUD STORAGE
Notes
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy&,de Compliance Forms for Commercial, R2 and R3 over japries and all R1 - Page 6 of 20 <br />2015 Washinaton State Enerov Code Compliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: SnoPUD75BC Date 18/02/27 <br />The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br />Washington State Energy Code, Commercial Provisions. <br />Applicable <br />Code Section <br />I <br />Code Provision <br />I <br />Information Required - Must be in permit documents <br />I <br />Location in <br />Building Department <br />es,no,na) <br />Documents <br />Notes <br />C403.2.4.3 <br />Stairway and shaft vent <br />Indicate location of stairway and shaft vent dampers on plans; verify dampers are Class 1 <br />na <br />dampers <br />motorized; refer to HVAC System Controls for additional requirements <br />For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that <br />na <br />C403.2.4.4 <br />Zone isolation dampers <br />are expected to be occupied non -simultaneously; identify isolation zone areas on plans and <br />locations of associated isolation dampers in HVAC distribution system; refer to HVAC System <br />Controls for additional requirements <br />For cooling systems with humidification equipment that are also required to have air <br />na <br />C403.2.3.4 <br />Humidification <br />economizer, indicate humidifier is adiabatic (direct evaporative or fog atomization), or <br />exception taken <br />Additional Efficiency Package <br />Option, More Efficient HVAC Equipment & fan Performance - <br />Must comply with all 3 <br />provisions to be eligible <br />C406.2.1 <br />To comply with additional efficiency package option, calculate the percentage of heating and <br />na <br />C403.2.3 <br />HVAC system selection <br />cooling equipment in the project (based on output capacity) that do not have a corresponding <br />WSEC listed efficiency; shall be less than 10% to comply <br />C406.2.2 <br />Minimum equipment <br />To comply with additional efficiency package option, indicate that all listed heating and cooling <br />na <br />C403.2.3 <br />efficiency <br />equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br />C406.2.3 <br />3Minimum <br />_ <br />To comply with additional efficiency package option, indicate rated FEG of stand alone fans is> <br />na <br />C403.2.11.3C406. <br />fan efficiency <br />71; indicate these fans are sized so the fan efficiency at design conditions is within 10% of the <br />maximum total or static efficiency <br />HVAC System Controls <br />Indicate locations of thermostatic and humidity control devices and the zones they serve on <br />plans, including perimeter system zones <br />Where adjacent (neighboring) zones are controlled by separate thermostats (including <br />perimeter systems used to offset heat gain or loss), and are connected by permanent <br />Thermostatic controls <br />openings > 10% of either zone sf area, indicate controls configured to prevent adjacent zones <br />NA <br />C403.2.4.1 <br />(thermostats and <br />from operating in conflicting modes (one in heat, other in cool); applies to adjacent perimeter <br />humidistats) <br />zones, adjacent nonperimeter zones, and adjacent perimeter and nonperimeter zones <br />If applying Exception 2 to nonperimeter zones adjacent to perimeter zones, indicate that <br />setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter <br />zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br />perimeter zone temperature in heating <br />na <br />C403.2.4.1.1 <br />Heat pump supplementary <br />Indicate staged heating operation with compression as the first stage of heating and <br />heat <br />supplemental heating controlled with outdoor lock -out temperature set to 40°F or less <br />NA <br />C403.2.4.1.2 <br />Deadband <br />Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that <br />control both heating and cooling <br />If separate heating and cooling systems with separate thermostatic control devices are used to <br />Setpoint overlap restriction <br />serve a zone, indicate locations of both thermostatic control devices and the zone they serve <br />na <br />C403.2.4.1.3 <br />(thermostats) <br />on plans <br />Indicate a limit switch, mechanical stop or DDC control with programming to prevent <br />simultaneous heating and cooling <br />C403.2.4.2 <br />Automatic setback and <br />Indicate zone thermostatic controls configured with required automatic setback and manual <br />na <br />C403.2.4.2.1 <br />shutdown <br />override functions, setback temperatures, and control method (automatic time clock or <br />C403.2.4.2.2 <br />programmable controls); note exceptions taken <br />na <br />C403.2.4.2.3 <br />Automatic (optimum) start <br />Indicate system controls that adjust equipment start time required to bring each area served up <br />to design temperature just prior to scheduled occupancy <br />NA <br />C403.2.4.3 <br />Outdoor supply air dampers <br />Indicate automatic controls configured to close OSA damper during unoccupied equipment <br />operation; not including economizer cooling, night flush or IMC required OSA / exhaust <br />na <br />C403.2.4.3 <br />Stairway and shaft vent <br />Indicate method of activation of stairway and shaft vent dampers (fire alarm or interruption of <br />dampers <br />power) <br />For systems serving areas > 25,000 sf or spanning more than one floor, that include areas that <br />na <br />C403.2.4.4 <br />Zone isolation controls <br />are expected to be occupied non -simultaneously; indicate controls that allow for independent <br />space conditioning of isolation zones; or exception taken <br />na <br />C403.2.12 <br />Heating outside a building <br />Indicate occupancy sensing or timer switch controls configured to automatically shut off <br />heating system when area served is unoccupied <br />na <br />C403.2.4.5 <br />Snow melt systems <br />Indicate automatic controls configured to shut off system when pavement temperature <br />exceeds 50°F and no precipitation is falling, and when outdoor air temperature exceeds 40°F <br />na <br />C403.2.4.6 <br />Freeze protection system <br />Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F, or <br />controls <br />conditions protect fluid from freezing <br />Group R1 hotel / motel <br />For hotels and motels with over 50 guest rooms, indicate automatic controls serving guest <br />na <br />C403.2.4.9 <br />guest rooms <br />rooms that are capable of setback (heating) and set-up (cooling) of temperature setpoint by at <br />least 5°F; indicate control method - activated by room entry or occupancy sensor <br />
The URL can be used to link to this page
Your browser does not support the video tag.