Laserfiche WebLink
2015 Washington State Energyftde Compliance Forms for Commercial, R2 and R3 overAgLaries and all R1 - Page 7 of 20 <br />209 s Washinntnn State Fnemv Cnde Cmmnlinnne Fnrms for Cnmmercial Ruildinns including R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: SnoPUD75BC Date 18/02/27 <br />The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br />Washington State Energy Code, Commercial Provisions. <br />Applicable <br />Code Section <br />Code Provision <br />Information Required - Must be in permit documents <br />Location in <br />Building Department <br />( es,no,na) <br />Documents <br />Notes <br />C403.2.4.10 <br />Group R2 / R3 dwelling <br />For primary space conditioning system, indicate 5-2 programmable thermostats capable of two <br />na <br />C403.2.4.11 <br />units, Group R2 sleeping <br />setback periods per day; for all thermostats indicate purpose (heating only, cooling only, or <br />units <br />both), required temperature range and at minimum a 10°F deadband; or exception taken <br />Indicate method of ventilation air delivery (natural or mechanical) for each zone <br />If mechanically delivered, indicate that systems are configured to provide not more than 150:/ <br />NA <br />C403.2.6 <br />Ventilation <br />of, but at least the minimum required volume of outdoor air to each zone per IMC, ASHRAE <br />C403.2.11.4 <br />62.1 or other applicable code (WAC, OSHA, etc); or exception taken <br />If delivered via natural ventilation, identify required elements per IMC including minimum <br />openable area to the outdoors or qualifying adjoining spaces <br />Identify spaces > 500 sf with occupant load > 25 people/1,000 sf per IMC; for each space <br />indicate whether it is served by an HVAC system with total design OSA > 3,000 cfm, and / or <br />na <br />C403.2.6.2 <br />Demand controlled <br />the system has airside economizer or automatic modulating OSA damper; indicate OSA <br />ventilation <br />controls are configured to provide demand controlled ventilation or provide supporting <br />documentation for applied exception <br />For gyms, classrooms, auditoriums and conference rooms > 500 sf, indicate occupancy -based <br />na <br />C403.2.6.3 <br />Occupancy sensors <br />OSA control when space is unoccupied and method (closes OSA damper or shuts -off <br />equipment); or alternate means provided to automatically reduce OSA when space is partially <br />occupied <br />C403.2.6.4 <br />Enclosed loading dock <br />For enclosed loading docks, indicate ventilation / exhaust system method of activation (gas <br />na <br />C403.2.6.4.1 <br />ventilation <br />detection system for CO and NO2, or occupancy sensors), and control method (staged or <br />modulating) <br />C403.2.6.4 <br />Enclosed parking garage <br />For enclosed parking garages, indicate ventilation / exhaust system activated by gas detection <br />na <br />C403.2.6.4.2 <br />ventilation <br />system for CO and NO2, and control method (staged or modulating); or exception taken <br />Provide calculations that show a balanced accounting of total kitchen exhaust (include all <br />hoods) with % of: supply air, transfer air from adjacent spaces, and make-up air; if applicable, <br />indicate that direct make-up air to each hood does not exceed 10%of hood exhaust <br />na <br />C403.2.7.1 <br />Kitchen exhaust hoods <br />For kitchens with total hood exhaust exceeding 2,000 cfm, indicate exhaust air rate per Table <br />C403.2.7.1 and compliance method (DCV, energy recovery, or transfer air that would <br />otherwise be exhausted) <br />na <br />C403.2.7.2 <br />Laboratory exhaust systems <br />Refer to Systems Requiring Energy Recovery for requirements <br />Variable flow capacity - <br />For HVAC fan motors >_ 7.5 hp, indicate method of variable flow control (VSD, or equivalent <br />na <br />C403.2.13 <br />HVAC system fans <br />control method that reduces design air volume by 50 / at 1/3 static design pressure); note <br />exception taken <br />DX air handler variable <br />For DX air handlers with economizer and cooling capacity;?: 65,000 Btu/h, indicate number of <br />cooling stages provided and method (multiple compressors and / or variable speed <br />na <br />C403.3.1 <br />cooling control <br />compressors); indicate minimum displacement (capacity reduction) as % of full load <br />(Under Integrated <br />Indicate control method (cooling capacity controlled in response to space temperature, space <br />Economizer) <br />temperature controlled by modulating supply airflow, or both) <br />For DX air handling units with cooling capacity>_ 65,000 Btu/h and evaporative and chilled <br />water air handling units with fan>_ 0.25 hp; indicate whether system is single zone or multiple <br />zone and related control method (cooling capacity controlled in response to space <br />temperature, space temperature is controlled by modulating supply airflow, or both) <br />For mechanical cooling systems (includes DX and chilled water coils) that control cooling <br />capacity in response to space temperature - Provide a minimum of two stages of fan control; <br />na <br />C403.2.11.5 <br />Fan airflow control <br />indicate minimum fan speed is 5 66% of full speed drawing <_ 40% of full speed fan power <br />during periods of low cooling or ventilation only <br />For other mechanical cooling systems (includes DX and chilled water coils) that control space <br />temperature by modulating airflow (in lieu of, or in addition to, controlling capacity in response <br />to space temperature) - Provide fan controls for modulating supply airflow; indicate minimum <br />fan speed is <_ 50% of full speed drawing <_ 30% of full speed fan power during periods of low <br />cooling or ventilation only; or exception taken <br />Provide central and zone level DDC controls as required based on system application, <br />na <br />C403.2.4.12 <br />DDC system capabilities <br />capacity or size thresholds and other qualification per Table C403.2.4.12.1 <br />Identify all DDC system input / output control points; indicate capability for trending and <br />graphical display <br />Ducting Systems <br />C403.2.8.1 <br />Indicate on plans that all ductwork is constructed and sealed per IMC <br />For OSA ductwork, also indicate on plans that ductwork meets air leakage requirements per <br />NA <br />C403.2.8.3 <br />Duct construction <br />C402.5 and vapor retarder requirements per the IBC <br />C403.2.8.3 <br />Duct pressure classifications <br />Identify location of low, medium and high pressure ductwork on plans <br />Ln <br />C403.2.8.3.3 <br />High pressure duct leakage <br />Indicate high pressure duct leakage testing requirements on plans; provide test results to <br />test <br />Ijurisdiction when completed <br />