Laserfiche WebLink
2015 Washington State EnergyWe Compliance Forms for Commercial, R2 and R3 over 2M&ries and all R1 - Page 8 of 20 <br />2015 Washinaton State Enerov Code Comnliance Forms for Commercial Buildinas including R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: SnoPUD75BC Date 18/02/27 <br />The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br />Washington State Energy Code, Commercial Provisions. <br />Applicable <br />Code Section <br />F Code Provision <br />I <br />Information Required - Must be in permit documents <br />Location in <br />I <br />Building Department <br />Lyes,no,nal <br />Documents <br />Notes <br />For supply and return ductwork located in unconditioned space or outdoors, indicate R-value of <br />insulation on ductwork on plans; identify climate zone; note exceptions taken <br />For supply ductwork located in conditioned space, identify if design supply temperature is < <br />C403.2.8.1 <br />No <br />C403.2.8.2 <br />Duct insulation <br />55°F or > 105°F and indicate R-value of insulation on this ductwork on plans; note exception <br />taken <br />For OSA ductwork, shafts and plenums, indicate R-value of insulation on these elements on <br />tans per Table C402.1.3 for steel -framed walls; note exception taken <br />Piping Systems <br />Indicate design temperature range of fluid conveyed in piping and thickness of insulation (in <br />NA <br />C403.2.9 <br />Piping insulation <br />P g <br />inches) on hydronic piping plans; or exception taken <br />Piping insulation exposed to <br />Indicate method of protection of pipe insulation from damage / degradation on hydronic piping <br />NA <br />C403.2.9.1 <br />weather <br />plans <br />Economizers <br />Identify in equipment schedules on plans or in MECH-EQ forms all cooling systems requiring <br />air economizer controls <br />na <br />C403.3 <br />Air economizer required <br />Provide MECH-ECONO form indicating systems utilizing air economizer exceptions, including <br />those with water -side economizer in lieu of air economizer; indicate on plans eligible <br />exception(s) taken and measures to comply with exception(s) <br />Integrated economizer <br />Indicate air and water -side economizers are configured for partial cooling operation even <br />na <br />C403.3.1 <br />operation - air and water <br />where additional mechanical cooling is required to meet the load <br />Economizer heating system <br />Verify control method of HVAC systems with economizers does not increase building heating <br />na <br />C403.3.2 <br />impact - air and water <br />energy usage during normal operation <br />Indicate modulating OSA and return air dampers are configured to provide up to 100% OSA <br />na <br />C403.3.3.1 <br />Air economizer capacity <br />for cooling <br />Verify mechanical cooling controls are interlocked with air economizer controls so the outside <br />air damper remains in 100% open position when mechanical cooling is also required to meet <br />na <br />C403.3.1 <br />Integrated air economizer <br />the cooling load, until the leaving air temperature is < 45°F <br />C403.3.3.2 <br />For systems with cooling capacity >_ 65,000 Btu/h, verify that control of economizer dampers is <br />not based only on mixed air temperature; or exception taken <br />na <br />C403.3.3.3 <br />Air economizer high limit <br />Indicate high limit shut-off control method and required high limit per Table C403.3.3.3 <br />controls <br />For eligible systems where water -side economizer may be provided in lieu of air economizer, <br />na <br />C403.3.4.1 <br />Water economizer capacity <br />indicate system is capable of 100% design cooling capacity at 50°F db / 45°F wb OSA <br />temperatures <br />C403.3.4.2 <br />Water economizer <br />Indicate pressure drop across precooling coils and heat exchangers in water economizer <br />na <br />maximum pressure drop <br />system do not exceed pressure drop limit <br />C403.3.1 <br />DX air handling equipment <br />For DX air handlers with economizer and cooling capacity z 65,000 Btu/h, refer to HVAC <br />na <br />control <br />System Controls for requirements <br />DX equipment economizer <br />For DX air handlers with economizer and cooling capacity>_ 54,000 Btu/h, provide a fault <br />na <br />C403.2.4.7 <br />fault detection and <br />detection and diagnostics (FDD) system to monitor economizer system operation and report <br />diagnostics <br />faults <br />Systems Requiring Energy <br />Recovery <br />For systems with design OSA > 5,000 cfm, or design supply air cfm and % OSA exceeding the <br />values in Tables C403.5.1(1) or (2), indicate exhaust air ER method; or exception taken with <br />supporting calculations <br />Energy recovery (ER) - <br />For rooms served by multiple systems with aggregate design OSA > 5,000 cfm, or aggregate <br />na <br />C403.5.1 <br />ventilation / exhaust <br />systems <br />design supply air cfm and % OSA exceeding the values in Tables C403.5.1(1) or (2), indicate <br />exhaust air ER method; or exception taken with supporting calculations <br />Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50% based on delta <br />between OSA and return air enthalpies at design conditions <br />Laboratory exhaust systems <br />For buildings with total lab exhaust > 5,000 cfm, indicate method of energy recovery used to <br />na <br />C403.2.7.2 <br />(energy recovery) <br />pre -condition laboratory make-up air; ER effectiveness (min 25°F); or alternative method per <br />exception (VAV exhaust, semi -conditioned makeup, or CERM calculation) <br />For buildings with pools or spas with water surface area > 200 sf, indicate exhaust air ER <br />C404.10.4 <br />Pools and permanent spas <br />method and use of waste heat (preheat ventilation air, pool water or service hot water); or <br />na <br />(under <br />exhaust systems <br />exception taken <br />C404.11) <br />(energy recovery) <br />Indicate ER system has the rated effectiveness and is configured to decrease the exhaust air <br />temperature at design conditions by >_ 36°F <br />Energy recovery - <br />For buildings with on -site steam heating systems, indicate condensate water ER <br />For buildings that use off -site generated steam where condensate is not returned to the <br />na I <br />C403.5.2 <br />steam condensate systems <br />source, indicate on -site condensate water ER <br />