Laserfiche WebLink
2015 Washington State EnergAkde Compliance Forms for Commercial, R2 and R3 over,11&ries and all R1 - Page 9 of 20 <br />2015 Washinaton State Enerov Code ComDliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: SnoPUD76BC Date 18/02/27 <br />The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br />Washington State Energy Code, Commercial Provisions. <br />Applicable <br />Code Section <br />Code Provision <br />Information Required - Must be in permit documents <br />Location in <br />Building Department <br />es,no,na <br />Documents <br />Notes <br />For buildings with food service, meat or deli departments that have >_ 500,000 Btu/h of remote <br />refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy <br />(service water heating, space heating, or dehumidification reheating) <br />na <br />C403.5.3 <br />Energy recovery - <br />For buildings with >_ 40,000 sf conditioned floor area and with >_ 1,000,000 Btu/h of remote <br />cooler / freezer condensers <br />refrigeration capacity for coolers / freezers, indicate condenser ER and use of captured energy <br />for service water heating and also for space heating, or dehumidification reheating <br />For buildings with 24-hour operation and with > 1,500,000 Btu/h of heat rejection capacity and <br />na <br />C403.5.4 <br />Energy recovery - <br />design service hot water load > 250,000 Btu/h, indicate condenser ER to pre -heat service <br />condenser systems <br />water; or exception taken. Provide calculations showing the amount of recovered heat that is <br />utilized (60% of peak heat rejection load or pre -heat service water to 85"F). <br />Hydronic System Controls <br />For hydronic system pump motors >_ 7.5 hp, indicate method of variable flow control (VSD or <br />equivalent method that requires ? 30% design wattage at 50% design fluid flow); note <br />na <br />C403.2.13 <br />Variable flow control - <br />exception taken <br />C403.4.2.7 <br />hydronic system pumps <br />-------- — ----—— ----- <br />Identify whether hydronic coils have DDC controls and associated manner of pump speed <br />— ----- <br />----- <br />control (differential pressure, zone hydronic demand, etc) <br />For boilers that provide building heating, indicate controls that provide heating water <br />temperature setback based on outdoor temperature <br />For heating and chilled water systems >_ 300,000 Btu/h, indicate systems are configured to <br />C403.2.5 <br />Hydronic system setback <br />automatically reset supply water temperature based upon demand; or exception taken. <br />na <br />If system pump motor hp >_ 3 hp, also indicate controls automatically reduce flow by >_ 50%. <br />C403.4.2.4 <br />and part load controls <br />For chilled water systems (>_ 300,000 Btu/h, pump motor hp a 3 hp) that serve water-cooled <br />unitary air conditioners, indicate VSD or staged pumps in chilled water system and heat <br />rejection loop that reduce pump flow so that one control valve is nearly wide open, or to <br />maintain a minimum differential pressure; or exception taken <br />na <br />C403.4.2 <br />Boiler sequencing <br />Indicate automatic controls that sequence operation of multiple boilers <br />na <br />C403.4.6 <br />Hot gas bypass limitation <br />For cooling equipment with hot gas bypass, provide either multiple step unloading or <br />continuous capacity modulation; indicate bypass capacity per Table C403.4.6 <br />na <br />C403.4.2.2 <br />Two -pipe changeover <br />Indicate changeover deadband (min 15°F), heating / cooling mode scheduling and changeover <br />systems <br />temperature range (limit 30°F) <br />na <br />C403.4.2.6 <br />Chiller / boiler plant pump <br />Indicate controls are configured to automatically reduce overall plant flow and shut-off flow <br />isolation <br />through individual chillers and boilers when not in use <br />For cooling towers with fan motors 2:7.5 hp, indicate VSD and method to adjust fan speed <br />C403.2.13.1.1 <br />Heat rejection equipment - <br />(adjusted based on leaving fluid temperature or condenser temperature / pressure of heat <br />NA <br />C403.4.3.1.1 <br />C403.4.3.1.2 <br />variable flow control <br />rejection device) <br />For multiple -cell heat rejection equipment with VSD, indicate controls that ramp all fans in <br />unison <br />C403.4.3.3 <br />Heat rejection equipment - <br />Indicate open -circuit cooling towers with multiple pumps or VSD control are designed so all <br />na <br />cooling tower flow turndown <br />cells can be run in parallel <br />na <br />C403.4.2.3.1 <br />Water loop heat pump - <br />Indicate capability of central equipment to provide minimum 20°F water supply temperature <br />deadband <br />deadband between heat rejection and heat addition modes; or exception taken <br />Water loop heat pump - <br />Indicate type of cooling tower (open- or closed-circuit) in equipment schedule; indicate method <br />na <br />C403.4.2.3.2.1 <br />heat rejection equipment, <br />used to limit system heat loss when heat rejection is not needed <br />Zone 4 <br />Water loop heat pump - <br />For open- or closed-circuit cooling towers, provide a heat exchanger that separates the cooling <br />na <br />C403.4.2.3.2.2 <br />heat rejection equipment, <br />tower and heat pump loop <br />Zone 5 <br />na <br />C403.4.2.3.3 <br />Water loop heat pump - <br />For hydronic heat pump systems with total system power > 10 hp, indicate 2-way isolation <br />isolation valves <br />valves on each heat pump and variable flows stem control <br />Dedicated Outdoor Air Systems (DOAS) - Optional through 6/30/16, Prescriptive 7/1/2016 <br />For buildings with office, retail, education, library and fire station spaces, identify these spaces <br />NA <br />C403.6 <br />Dedicated outdoor air <br />on plans; indicate that ventilation air in each occupied space is provided via a DOAS system; <br />C403.6.3 <br />systems <br />or document compliance with C403.6.3 Impracticality; or exception taken (buildings complying <br />with C402.4.1.4 or C406.6 may not utilize exceptions) <br />Energy recovery ventilation <br />For all DOAS systems, indicate exhaust air ER method; or exception taken with supporting <br />NA <br />C403.6.1 <br />with DOAS <br />calculations. Indicate ER rated effectiveness that increases OSA enthalpy by >_ 50 /o based on <br />delta between OSA and return air enthalpies at design conditions. <br />Indicate equipment associated with the delivery of zone level heating and cooling (fans, <br />Heating / cooling system <br />hydronic pumps, primary air dampers, etc) are configured to shut off, and central equipment is <br />NA <br />C403.6.2 <br />controls with DOAS <br />configured to turn down, when there is no call for heating or cooling in the zone they serve <br />If applying Exception to heating / cooling fans used for air mixing in the space during deadband <br />periods, include fan watts per cfm in equipment schedule <br />