My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1122 75TH ST SW PUD STORAGE 2021-12-28
>
Address Records
>
75TH ST SW
>
1122
>
PUD STORAGE
>
1122 75TH ST SW PUD STORAGE 2021-12-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 12:41:00 PM
Creation date
11/10/2021 10:59:43 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1122
Tenant Name
PUD STORAGE
Notes
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energylil Compliance Forms for Commercial, R2 and R3 over Mies and all R1 - Page 10 of 20 <br />2015 Washinaton State Enerav Code Comoliance Forms for Commercial Buildings includina R2 & R3 over 3 stories and all R1 Revised January 2017 <br />Project Title: SnoPUD75BC Date 18/02/27 <br />The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br />Washington State Energy Code, Commercial Provisions. <br />Applicable <br />Code Section <br />F Code Provision <br />Information Required - Must be in permit documents <br />Location in <br />Building Department <br />yes,no,na) <br />Documents <br />Notes <br />C402.4.1.4 <br />Increased prescriptive <br />NA <br />maximum vertical <br />Indicate that all occupied, conditioned spaces are served by a DOAS per C403.6 <br />C403.6 <br />fenestration area with DOAS <br />Additional Efficiency Package Option, Dedicated Outside Air Systems (DOAS) <br />C406.6 <br />Building provided with <br />To comply with additional efficiency package option, indicate that 90% or more of all occupied, <br />na <br />DOAS <br />conditioned spaces are served by a DOAS per C403.6 <br />Multiple Zone Air Systems <br />Air systems serving multiple <br />Identify supply air systems serving multiple zones and the zones they serve on plans; indicate <br />na <br />C403.4.4 <br />whether system is VAV and method of primary air control; or provide supporting <br />zones <br />documentation for applied exception to VAV <br />Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and <br />types <br />For each air terminal include: maximum airflow rates for primary supply air during zone peak <br />VAV systems serving <br />na <br />C403.4.4 <br />multiple zones <br />heating and zone peak cooling; maximum airflow during reheating, recooling or mixing; <br />minimum airflow rate to maintain required ventilation, and the basis for these values; if IMC or <br />ASHRAE 62.1 multiple zone equation is basis for minimum flow rates, provide calculation on <br />plans <br />C403.4.4.1 <br />Single duct VAV terminal <br />Indicate single duct terminal units are configured to reduce primary supply air before reheating <br />na <br />units <br />or retooling <br />C403.4.4.2 <br />Dual duct systems - terminal <br />For systems with separate warm air and cool air ducts, indicate terminal units are configured to <br />na <br />units <br />reduce the flow from one duct to minimum before mixing with air from the other duct <br />Indicate locations of duct static pressure sensors on plans; include at least one sensor per <br />major duct branch; verify controller setpoint pressure at each sensor is < 1.2 inch w.g. <br />For systems with zone level DDC, indicate controls are configured to monitor zone damper <br />C403.4.1.1 <br />VAV system static <br />na <br />C403.4.1.2 <br />pressure sensors - <br />sensors and DDC set points <br />positions and reset static pressure setpoint based on the zone requiring most pressure; include <br />control logic that automatically detects and generates an alarm if any zone excessively drives <br />reset logic, and allows building operators to exclude zones from reset logic <br />Multiple -zone VAV system <br />For systems with zone level DDC controls, indicate controls are configured to automatically <br />na <br />C403.4.4.3 <br />ventilation optimization <br />reduce outdoor airflow in response to changes in system ventilation efficiency; or exception <br />controls <br />taken <br />na <br />C403.4.4.4 <br />VAV system supply air reset <br />Indicate controls automatically reset supply air temperature in response to building loads or <br />outdoor air temperature; or exception taken <br />Multiple Zone HVAC Systems, High Efficiency VAV - Required for systems utilizing C403.6 DOAS Exception 2, must comply with all 16 provisions <br />C403.7, <br />Indicate system is configured for 100% air economizer operation and complies with all related <br />na <br />Item 1 <br />Air economizer <br />economizer requirements per C403.3 (without economizer exceptions) <br />na <br />C403.7, <br />Direct digital controls (DDC) <br />Provide DDC controls for all components of system; identify all DDC system input / output <br />Item 2 <br />control points; indicate capability for trending and graphical display <br />For systems with minimum OSA > 2,500 cfm, indicate outdoor airflow monitoring station that <br />C403.7, <br />Outdoor airflow, <br />measures OSA intake under all load conditions; indicate control sequence that increases or <br />na <br />Item 3 <br />measurement and reduction <br />reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency (per <br />C403.4.4.3 without exceptions) or DCV (per C403.2.6.2) <br />na <br />C403.7, <br />Supply airflow measurement <br />For systems with minimum OSA > 2,500 cfm, indicate supply airflow monitoring station capable <br />Item 4 <br />of measuring supply su I air delivered to VAV terminals under all load conditions <br />C403.7, <br />Zone isolation and <br />Verify maximum area served by a single HEVAV system is < 50,000 sf, or one entire floor, <br />na <br />Item 5 <br />maximum area served <br />whichever is greater; in addition if a system serves > 25,000 sf, that includes areas that are <br />expected to be occupied non -simultaneously, indicate zone isolation controls per C403.2.4.4 <br />C403.7, <br />Interior / exterior zone <br />Verify that VAV terminals serving interior cooling driven loads are sized per design supply air <br />na <br />Item 6 <br />design supply air <br />temperature that is 5°F higher than VAV terminals serving exterior zones <br />temperature <br />C403.7, <br />Maximum air terminal inlet <br />Identify air terminals with minimum primary airflow setpoints > 50% of maximum setpoint in <br />na <br />Item 7 <br />velocity <br />equipment schedule or MECH-EQ form; indicate air terminal inlet velocity does not exceed 900 <br />fpm <br />na <br />C403.7, <br />Sequence of operation <br />Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC <br />Item 8 <br />36 <br />C403.7, <br />Maximum allowable system <br />Verify fan system bhp is < 90% of the bhp limit per Option 2 equation in Table C403.2.11.1(1), <br />na <br />Item 9 <br />brake horsepower <br />provide MECH-FANSYS form for each system <br />Indicate all series and parallel terminal fans have electronically commutated motors; indicate <br />C403.7, <br />Fan powered terminal unit <br />DDC control system is configured to vary air terminal fan speed as a function of the load; <br />na <br />Item 10 <br />motor and control <br />indicate fan speed during periods of low heating, low cooling, or ventilation only is< 66% of <br />peak design air flow or provide supporting documentation for applied exception <br />
The URL can be used to link to this page
Your browser does not support the video tag.