Laserfiche WebLink
.- Port of Everett <br /> Engineering&Planning <br /> DESIGN REVIEW COMMENT FORM <br /> Submittal(%): 100% ISSUED FOR PERMIT REVIEW Project No.: 154016.012 <br /> Project Title: SE MILLWRIGHT LOOP AND OPEN SPACES Port's CIP No.: 6-8-002-01, 6-8-002-02, <br /> 6-8-002-03, 6-8-002-04 <br /> Port's Project Manager/Phone: BRANDON WHITAKER, (425) 388-0613 Dept-Reviewer(s):CITY OF EVERETT <br /> Project NE: PND ENGINEERS Due Date: <br /> Drawing or Reviewer Comment NE Response/Resolution 0, . o <br /> z 3 . Specification '> o 0 <br /> • E .52 "4..- Reference c) a <br /> YIN YIN <br /> 1. COE T1.01, ETC. "100% Issued for Permit Review- Not for Construction"- The note has been removed. / <br /> update, for permit issuance set. TYP all sheets. Must be '1// <br /> the approved plans that the contractor builds from. <br /> 2. COE T1.01, ETC Need Engineers Stamp & Signature Noted - \,/ <br /> 3. COE D1.02 Add note"Coordinate all water line work with COE Water PND will add the following note: "The Contractor <br /> Dept. Only COE can work on live valves, mains, hydrants, shall coordinate all waterline work with the COE Water <br /> etc. Contact Jim Spooner, 425-257-8827, Dept. City of Everett crew to perform all work on live <br /> JSpooner(c�everettwa.gov" water appurtenances (including existing valves, mains, <br /> hydrants, etc.). COE will perform this work under a <br /> separate utility permit paid for at the Owner's expense. <br /> Contact Jim Spooner, 425-257-8827, <br /> J Sjoo ne rCa�everettwa.gov." <br /> Ank 4. COE C2.04 Edit Note"Reinforced Grass See C2.06 and Landscaping" PND has corrected note to read "Reinforced Grass <br /> See C2.05 and Landscaping" �/ <br /> 5. COE C2.04 Inside turn radius must be 28' minimum. Fire Truck turning PND has proposed a 10 ft inside radius which allows <br /> maneuver on-site required prior to pouring curbs. for a 28-ft fire turning radius per correspondence <br /> Coordinate with Fire Dept. Jim Venturo 425-257-8124 between the POE and COE Fire Dept on 7-6-18 <br /> 6. COE C2.05 Grasscrete needs to be able to hold Fire Truck Weight of GEOBLOCK 5150 specification summary attacheds Otrrellifl`" <br /> 75,000 lbs. Need calcs & Specs on weight distribution The section specified for the SE Millwright Loop and Y` I <br /> submitted for review/approval. Open Spaces project meets the Heavy Fire Truck <br /> Access & H/HS-20 Loading load description. <br /> 7. COE C2.05 Fire department requires no bollards. Remove from plans, Noted, detail and callout have been removed. 11.�v` l <br /> all applicable sheets in plan set. <br /> 8. COE C4.02 Sewer Dept is asking why this manhole is needed, and Noted, manhole has been removed. I <br /> recommend removing it. <br /> 154016_SEMWL Permit Revisions Comment Responses.docx ( Page 1 of 3) <br />