My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1205 CRAFTSMAN WAY PORT OF EVERETT 2022-01-13
>
Address Records
>
CRAFTSMAN WAY
>
1205
>
PORT OF EVERETT
>
1205 CRAFTSMAN WAY PORT OF EVERETT 2022-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2022 2:04:11 PM
Creation date
1/11/2022 4:25:18 PM
Metadata
Fields
Template:
Address Document
Street Name
CRAFTSMAN WAY
Street Number
1205
Tenant Name
PORT OF EVERETT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.- Port of Everett <br /> Engineering&Planning <br /> DESIGN REVIEW COMMENT FORM <br /> Submittal(%): 100% ISSUED FOR PERMIT REVIEW Project No.: 154016.012 <br /> Project Title: SE MILLWRIGHT LOOP AND OPEN SPACES Port's CIP No.: 6-8-002-01, 6-8-002-02, <br /> 6-8-002-03, 6-8-002-04 <br /> Port's Project Manager/Phone: BRANDON WHITAKER, (425) 388-0613 Dept-Reviewer(s):CITY OF EVERETT <br /> Project NE: PND ENGINEERS Due Date: <br /> Drawing or Reviewer Comment NE Response/Resolution 0, . o <br /> z 3 . Specification '> o 0 <br /> • E .52 "4..- Reference c) a <br /> YIN YIN <br /> 1. COE T1.01, ETC. "100% Issued for Permit Review- Not for Construction"- The note has been removed. / <br /> update, for permit issuance set. TYP all sheets. Must be '1// <br /> the approved plans that the contractor builds from. <br /> 2. COE T1.01, ETC Need Engineers Stamp & Signature Noted - \,/ <br /> 3. COE D1.02 Add note"Coordinate all water line work with COE Water PND will add the following note: "The Contractor <br /> Dept. Only COE can work on live valves, mains, hydrants, shall coordinate all waterline work with the COE Water <br /> etc. Contact Jim Spooner, 425-257-8827, Dept. City of Everett crew to perform all work on live <br /> JSpooner(c�everettwa.gov" water appurtenances (including existing valves, mains, <br /> hydrants, etc.). COE will perform this work under a <br /> separate utility permit paid for at the Owner's expense. <br /> Contact Jim Spooner, 425-257-8827, <br /> J Sjoo ne rCa�everettwa.gov." <br /> Ank 4. COE C2.04 Edit Note"Reinforced Grass See C2.06 and Landscaping" PND has corrected note to read "Reinforced Grass <br /> See C2.05 and Landscaping" �/ <br /> 5. COE C2.04 Inside turn radius must be 28' minimum. Fire Truck turning PND has proposed a 10 ft inside radius which allows <br /> maneuver on-site required prior to pouring curbs. for a 28-ft fire turning radius per correspondence <br /> Coordinate with Fire Dept. Jim Venturo 425-257-8124 between the POE and COE Fire Dept on 7-6-18 <br /> 6. COE C2.05 Grasscrete needs to be able to hold Fire Truck Weight of GEOBLOCK 5150 specification summary attacheds Otrrellifl`" <br /> 75,000 lbs. Need calcs & Specs on weight distribution The section specified for the SE Millwright Loop and Y` I <br /> submitted for review/approval. Open Spaces project meets the Heavy Fire Truck <br /> Access & H/HS-20 Loading load description. <br /> 7. COE C2.05 Fire department requires no bollards. Remove from plans, Noted, detail and callout have been removed. 11.�v` l <br /> all applicable sheets in plan set. <br /> 8. COE C4.02 Sewer Dept is asking why this manhole is needed, and Noted, manhole has been removed. I <br /> recommend removing it. <br /> 154016_SEMWL Permit Revisions Comment Responses.docx ( Page 1 of 3) <br />
The URL can be used to link to this page
Your browser does not support the video tag.