• • <br /> Mr. Michael Snitko <br /> Washington Flippers, LLC <br /> Plan Check Number: CW1910-001, First Structural Review <br /> December 13, 2019 <br /> 12.The project includes a new exterior wood-framed deck. The framing is specified as pressure- <br /> treated wood. However, it is understood from observations of the as-built conditions that the <br /> framing is not treated or naturally-durable wood. The following comments shall be addressed: <br /> a. The deck construction shall be revised to provide the required treated wood or the framing <br /> shall be protected to prevent exposure. <br /> b. The wood notes in the Structural General Notes should include a general statement <br /> requiring all wood exposed to weather to be preservative-treated or naturally-durable wood. <br /> c. The wood notes in the Structural General Notes should require the cut ends and surfaces <br /> (e.g., trimmed framing, stair cut-outs, etc.) of preservative-treated wood to be coated with <br /> a preservative treatment complying with AWPA U1. See IBC Sections 2304.12.1 and <br /> 2304.12.2.3. <br /> Gravity System: <br /> 13.The framing layout on Sheet S1 appears to indicate that the roof construction at the west end <br /> of the building has been completely revised, modifying the.original gravity load paths for the <br /> building. The intended load paths are not clear and cannot be verified to be continuous to the <br /> foundation. See IBC Sections 107.2.1, 1603.1, 1604.4, and 1604.4. <br /> a. Revised framing plans should be submitted showing all framing in the load path from the <br /> roof to the foundation. The plans should delineate between new and existing framing using <br /> standard drafting conventions. <br /> b. Sections and details should be provided to clearly show the intended construction. Details <br /> for connections between framing, and for framing to supporting walls, should be included. <br /> c. Structural calculations should be submitted substantiating the capacity of all existing and <br /> new framing in the load path. The calculations shall also substantiate the design of all <br /> connections in the load path. <br /> 14.The roof framing on Sheet S1 for the west end of the building includes two new 5 1/2"GLBs. <br /> The beams have been designed as simply-supported members only. However, the plan <br /> appears to indicate that the beams cantilever at the east end up to 10 feet, inducing negative <br /> bending. Revised calculations for the design of the beams should be submitted for review. See <br /> IBC Sections 1604.1 and 1604.4. <br /> 15.The roof framing on Sheet S1 for the west end of the building appears to be primarily <br /> supported at the interior by wood posts. The size of the posts, and whether the posts are new <br /> or existing, is not specified. Based on a review of the existing and proposed framing plans, the <br /> posts will be subject to increased loading for the proposed design, in part due to high tributary <br /> loads caused by the cantilever condition in the 5 1/2"GLBs. Calculations substantiating the <br /> design of the posts should be submitted for review. The load path supporting the posts and <br /> transferring loads to the foundation shall also be substantiated. See IBC Sections 1604.1 and <br /> 1604.4. <br /> O3200 Cedar Street 0 425.257.8810 0 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> ge4of7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.