KPFF Consulting Engineers 12/30/2021
>
Contracts
>
Agreement
>
Professional Services (PSA)
>
KPFF Consulting Engineers 12/30/2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 10:26:31 AM
Creation date
1/21/2022 2:39:07 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KPFF Consulting Engineers
Approval Date
12/30/2021
Council Approval Date
12/22/2021
End Date
12/30/2025
Department
Parks
Department Project Manager
Dean Shaughnessy
Subject / Project Title
Later Phase Eclipse Mill Park Project
Tracking Number
0003149
Total Compensation
$600,000.00
Contract Type
Agreement
Contract Subtype
Professional Services
Retention Period
6 Years Then Destroy
Document Relationships
KPFF Consulting Engineers 1/18/2024 Amendment 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Agreement\Professional Services (PSA)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Later Phase Eclipse Mill Project <br /> The CONSULTANT shall prepare a Geotechnical Work Plan Memorandum for <br /> the proposed exploration program. The work plan will be submitted to the design <br /> team and the CITY for review and approval. The work plan will detail the type, <br /> location, and extent of proposed field explorations along with logistics necessary <br /> to perform the work such as access and staging areas. The work plans will also <br /> be used for utility locating clearances and for permitting that may be necessary to <br /> access the exploration locations. We assume that any required permits or rights <br /> of entry will be provided at no cost to the CONSULTANT. <br /> 300.3.3 Conduct Geotechnical Explorations <br /> The CONSULTANT shall conduct up to two days of limited access drilling in <br /> support of the bank stabilization design along the Lowell Riverfront Trail. All <br /> geotechnical explorations will be conducted with a rubber track mounted limited <br /> access drill rig. The drilling sites will be accessed by tracking along the Lowell <br /> Riverfront Trail. Each geotechnical boring will be drilled to a depth of 20 to 30 <br /> feet or practical refusal, whichever is shallower. No geotechnical borings will be <br /> drilled within the river. <br /> Each of the above-described geotechnical explorations will be logged by a <br /> licensed geologist. All drilling spoils will be drummed and transported off site for <br /> disposal by the driller. <br /> 300.3.4 Generate Boring Logs and Assign Laboratory Testing <br /> The CONSULTANT shall prepare summary boring and perform laboratory testing <br /> to evaluate relevant physical properties of the site soils. Laboratory testing will <br /> include moisture content, grain-size distribution, and Atterberg Limits. <br /> Subtask 300.4 Geotechnical Final Design <br /> The CONSULTANT shall conduct geotechnical final design analysis in support of <br /> development of the 100 percent design for the proposed improvements. The <br /> CONSULTANT shall provide the following services under this task. <br /> 300.4.1 Evaluate Field and Laboratory Data <br /> Based on the borings and the laboratory test results on selected samples, The <br /> CONSULTANT shall generate estimates of the soil strength and other properties <br /> needed to evaluate the effects the subsurface conditions will have on the <br /> proposed improvements. <br /> 300.4.2 Develop Geologic Cross-Sections <br /> The CONSULTANT shall develop new geologic cross-sections and update <br /> already completed cross sections, as needed, for the project. These cross <br /> sections will show near surface soil conditions, will be provided in a geotechnical <br /> report, and will be used to evaluate bank stabilization methods. <br /> 300.4.3 Update Seismic Design Parameters <br /> Based on the soils encountered across the site, The CONSULTANT shall update <br /> the seismic design parameters to meet current code requirements. The design <br /> spectral acceleration parameters will then be selected in accordance with the IBC <br /> code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.