• • <br /> Mr.John Bierly <br /> Wing Point Associates <br /> Plan Check Number: B2003-043, First Building Review <br /> May 14,2020 <br /> condition. HSS posts layouts have been revised to cover(4)corners for each car- <br /> stack unit. <br /> c. The framing plans on Sheets S2.3 and S2.4 do not consistently show the columns. In <br /> addition,the roof plan appears to be missing support framing for some of the columns. The <br /> design should be revised as needed. See IBC section 1603.1. Column layouts have been <br /> revised to match at both levels with the supplemental framing at the roof along <br /> gird El. <br /> Lateral System: <br /> 8. The proposed project includes the addition of seismic upgrades. The upgrades do not appear <br /> to be required based on a review of IEBC Sections 403 and 407.1. Please confirm if the <br /> upgrades are voluntary per Section 403.9. If the upgrades are not voluntary, please clarify. A <br /> brief project statement on the upgrades should be included in the General Structural Notes. <br /> Additional comments may be pending. See IBC Section 101.4.7 and 107.2.1.The seismic <br /> upgrades are voluntary.A brief project statement is provided in the structural calcs. <br /> Miscellaneous: <br /> 9. The project scope includes a new elevator. The following comments should be addressed: <br /> a. The elevator design drawings should be included in the list of deferred submittals in the <br /> General Structural Notes. See IBC Section 107.3.4.1. Elevator design drawings have <br /> been included in the list of deferred submittals in the General Structural Notes. <br /> b. The design loads for the elevator system, including impact loading, should be specified in <br /> the"Design loading Criteria"section of the General Structural Notes. When actual design <br /> loads are not available, estimated design loads should be specified for the design, and <br /> verified when the elevator design drawings are submitted for review. See IBC Sections <br /> 1603.1.8 and 1607.9.1. Estimated design loads have been specified in the General <br /> Structural Notes. <br /> c. The building framing (i.e., elevator shaft and supporting floor framing) is presumed to <br /> support the elevator system. Calculations substantiating the design of the structure to <br /> support the elevator loads concurrently with other loads should be submitted for review. <br /> The calculations should include the evaluation of deflection limits per IBC Section 1607.9.1. <br /> The design shall consider concurrent multi-directional loading as determined by the elevator <br /> manufacturer. See IBC Sections 1604.2 and 1605. The HSS rail support posts and <br /> wood beams supporting the elevator have been designed to accommodate the <br /> estimated design impact loads. Supplemental calculations have been provided. <br /> d. The connections between the elevator guide rails and the structural framing are typically the <br /> responsibility of the engineer-of-record for the building system. At a minimum, connection <br /> details between the rail bracket and structural framing are required. Calculations and <br /> details for the elevator connections to the structural framing should be submitted for review. <br /> The design shall consider concurrent multi-directional loading as determined by the elevator <br /> manufacturer. The required locations and maximum spacing for the connection points <br /> should be specified in the structural drawings. See IBC Section 107.2.1 and 1604.4. Refer <br /> V 3200 Cedar Street / '1 425.257.8810 0 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.