<br />1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING
<br />DEMOLITION,
<br />2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR
<br />LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES
<br />AND THE BUILDING REPRESENTATIVE,
<br />3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY,
<br />4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING
<br />REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO
<br />5. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO
<br />THE IMMEDIATE ATTENTION OF THE DESIGNER.,
<br />6, ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE
<br />AND IN PROPER ALIGNMENT, U.N.O.
<br />7. ALL DIMENSIONS ARE TO FINISH CONSTRUCTION, U.N.O. DIMENSIONS NOTED
<br />"HOLD" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN �
<br />1/8" WITHOUT" WRITTEN INSTRUCTION FROM DESIGNER. "ALIGN" MEANS TO
<br />ACCURATELY LOCATE 'FINISHED FACES IN THE SAME PLANE, DIMENSIONS NOTED
<br />"CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WITHOUT
<br />EXCEPTION, DIMENSIONS MARKED ± MEAN A VARIANCE NOT GREATER THAN 1
<br />INCH, VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH THE DESIGNER. ALL
<br />DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE FINISH FACE OF
<br />WALL BELOW SILL, U.N.O.
<br />E. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS
<br />TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT SURFACES.
<br />9, PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING
<br />SLABS, WALLS AND SHAFTS, SEAL ABANDONED PENETRATIONS AT FLOORS,
<br />WALLS AND SHAFTS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS,
<br />PATCH FIREPROOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED
<br />STRUCTURAL STEEL,
<br />10, REFER TO THE PARTITION TYPES FOP PARTITION THICKNESS ON SHEET A9-3.
<br />11. ALL NEW PARTITIONS ARE TYPE 5 ON SHEET A9-3, U.N,O.
<br />12. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS SHALL
<br />ACCOMMODATE FULL_ CONCEALMENT OF RECESSED CABINETS OR PARTIAL
<br />CONCEALMENT OF SEMI -RECESSED CABINETS AS SPECIFIED BY THE
<br />MANUFACTURER, REFER TO MOUNTING HEIGHT ON DETAIL 13 ON SHEET A7-2.
<br />13. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH
<br />NO VISIBLE JOINTS. .PROVIDE LEVEL 4 FINISH, U.N.O.
<br />14. REFER TO MATERIAL SCHEDULE & FINISH PLAN FOR MATERIALS & LOCATIONS
<br />THAT REQUIRE A LEVEL 5 FINISH, U.N.O,
<br />15. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM.
<br />16. CONTRACTOR SHALL COORDINATE REVIEW OF THE PARTITION LAYOUT WITH
<br />THE DESIGNER PRIOR TO PARTITION INSTALLATION.
<br />17. CONSTRUCTION OF FIRE -RATED PARTITIONS, INCLUDING TAPING AND FINISHING
<br />OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, SHALL BE IN
<br />ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED,
<br />18. WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING,
<br />SECURE THE TOP TRACK TO THE EXPOSED CEILING GRID, PROVIDE A
<br />COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE CEILING GRID.
<br />PROVIDE TRAPPABLE METAL J-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO
<br />JOINTS VARYING MORE THAN 1/8" OVER 6-0" AND NO JOINTS GREATER THAN
<br />3/16", U,N.O. CAULK PERIMETER AT TOP OF GWB,
<br />19. PROVIDE GROUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR
<br />SUPPORT OF CASEWORK, SHELF -STANDARDS, A/V DEVICES, FURNITURE, ETC,
<br />ALL CONCEALED LUMBER AND BLOCKING TO BE FIRE TREATED, COORDINATE
<br />BLOCKING REQUIREMENTS WITH FURNITURE & AV INSTALLERS. WHERE
<br />BLOCKING OR ADDITIONAL STUDS ARE REQUIRED AT EXISTING PARTITIONS,
<br />THEY ARE TO BE PATCHED AND REPAIRED, SEE CONSTRUCTION PLANS FOR
<br />WALL -MOUNTED MILLWORK; PROVIDE BLOCKING PER MANUFACTURERS"
<br />REQUIREMENTS,
<br />20. PROVIDE VERTICAL CONTROL JOINTS 30' O.C. MAX. IN ALL GWB PARTITIONS
<br />LONGER THAN 30'. WHEN :POSSIBLE CONTROL JOINTS SHOULD BE LOCATED
<br />ABOVE THE CORNER OF A DOOR OR OPENING.
<br />21. ALL HINGED DOORS TO BE 6" FROM NEAREST PERPENDICULAR PARTITION, U.N.O.
<br />DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB.
<br />ALL DOORS SHALL HAVE V-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND
<br />V-0 CLEAR ON THE STRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A
<br />CLOSER) VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING
<br />OUT PARTITIONS,
<br />22. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO BE
<br />USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS OF
<br />THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR SLAB
<br />OR FINISHED FLOOR THICKNESS.
<br />23. PROVIDE DOUBLE STUDS AT DOOR JAMBS. INSTALL ADDITIONAL STUDS IN
<br />EXISTING PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO PROVIDE DOUBLE
<br />STUDS AT JAMBS,
<br />24. PROVIDE DIAGONAL BRACING TO SLAB AT DOUBLE STUDS AT DOOR OPENINGS,
<br />25. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAGE
<br />(MINIMUM) @ 16" O.C, (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE
<br />LOCATIONS,
<br />26. GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING
<br />ROUGH -IN (E.G.BATHROOMS, BREAK AREA, MOOD ROOM) SHALL BE
<br />WATER-RESISTANT.
<br />27, GYPSUM WALLBOARD TO BE INSTALLED WITH NO HORIZONTAL JOINTS BETWEEN
<br />THE FLOOR AND SUSPENDED CEILING.
<br />Crest'Vd Crq.-n',,e Interial*S
<br />Design Studio
<br />o 1 th AveSouth, Suite E202
<br />Des Moines, WA 98198
<br />WWWCRESTEDCRANENTER�ORS,COM
<br />OLYMPIC HOT TUB
<br />811 SE EVERETT MALL WAY, SUITE
<br />EVERETT, WA 98208
<br />Description: Datea No.o
<br />PERMIT SET 02/15/2021
<br />NEW ENTRY DOOR REVISION 03/16/2021
<br />CONSTRUCTION KEYNOTES 010y
<br />101 FINISH WALL TO A LEVEL 5 UP J-O 10' AFF IN PREP FOR TENANT PROVIDED
<br />LOGO WALL COVERING,
<br />1.02 FURR OUT COLUMN AND ALIGN ROOM OPENING WITH NEW COLUMN FURRING.
<br />103 PROVIDE AND INSTALL THOSE BIB ADAPTER UNDER MOP SINK TUB PLUMBING,
<br />104 FINISH PARTITION WITH FULL HEIGHT DRYWALL ALONG SUITE DEMISING
<br />PARTITION. SEE PARTITION TYPE 7 ON SHEET A9-3,
<br />105 FINISH SUITE PERIMETER PARTITION TO MEET BUILDING THERMAL ENVELOPE
<br />REQUIREMENTS.
<br />106 COORDINATE WITH TENANT'S OPERATIONS MANAGER FOR FINAL LOCATION
<br />AND NECESSARY PREP FOR TENANT PROVIDED SUB -PANELS.
<br />OPS. MANAGER: ROB ANDERSON @ (253) 227-8013.
<br />107 PROVIDE AND INSTALL GROMMET WITH COVER TO ALLOW ACCESS FOR
<br />WATER HOSE TO PASS THROUGH AT LOWER PORTION OF PARTITION INTO
<br />MOOD ROOM.
<br />108 PROVIDE AND INSTALL PANIC DOOR HARDWARE WITH OPERATION
<br />INSTRUCTIONS TO COMPLY TO CURRENT CODE.
<br />109 HOT TUB, 10194 E
<br />➢TEOT/
<br />III REPLACE STOREFRONT WITH SAME GLAZING SIZE, UL, AND SPECIFICATIONS,
<br />GENERAL CONTRACTOR TO COORDINATE WITH GLAZING VENDOR TO ENSURE
<br />` U I
<br />THERE ARE NO CHANGE IN HEAT GAIN/LOSS OR SURFACE AREA OF GLAZING, I a
<br />sA AM E3 ➢L..k
<br />TATE OF VS111 0;T0N
<br />DEMOLITION & CONSTRUCTION LEGEND
<br />'.
<br />NOT IN CONTRACT (NIC)
<br />EXISTING WALL TO REMAIN
<br />= _ = EXISTING CONSTRUCTION TO BE REMOVED
<br />NEW CONSTRUCTION PER DETAIL 1/A1-1, UNO
<br />NEW DOOR & FRAME
<br />10
<br />ALIGN
<br />roj. o.: 811—T—EVE TT