Laserfiche WebLink
ELF <br />n <br />" <br />1/6" = 1'-U <br />(1) <br />NORTH <br />1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING <br />DEMOLITION, <br />2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR <br />LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES <br />AND THE BUILDING REPRESENTATIVE, <br />3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY, <br />4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING <br />REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO <br />5. CONFLICTS BETWEEN SITE CONDITIONS AND DRAWINGS SHALL BE BROUGHT TO <br />THE IMMEDIATE ATTENTION OF THE DESIGNER., <br />6, ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE <br />AND IN PROPER ALIGNMENT, U.N.O. <br />7. ALL DIMENSIONS ARE TO FINISH CONSTRUCTION, U.N.O. DIMENSIONS NOTED <br />"HOLD" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN � <br />1/8" WITHOUT" WRITTEN INSTRUCTION FROM DESIGNER. "ALIGN" MEANS TO <br />ACCURATELY LOCATE 'FINISHED FACES IN THE SAME PLANE, DIMENSIONS NOTED <br />"CLEAR" ARE MINIMUM DIMENSIONS WHICH MUST BE MAINTAINED WITHOUT <br />EXCEPTION, DIMENSIONS MARKED ± MEAN A VARIANCE NOT GREATER THAN 1 <br />INCH, VERIFY DIMENSIONS EXCEEDING TOLERANCE WITH THE DESIGNER. ALL <br />DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE FINISH FACE OF <br />WALL BELOW SILL, U.N.O. <br />E. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS, AND CORRIDOR WALLS <br />TO REMAIN ARE TO BE PATCHED AND REPAIRED TO MATCH ADJACENT SURFACES. <br />9, PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING <br />SLABS, WALLS AND SHAFTS, SEAL ABANDONED PENETRATIONS AT FLOORS, <br />WALLS AND SHAFTS TO MAINTAIN FIRE/SMOKE AND ACOUSTICAL RATINGS, <br />PATCH FIREPROOFING AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED <br />STRUCTURAL STEEL, <br />10, REFER TO THE PARTITION TYPES FOP PARTITION THICKNESS ON SHEET A9-3. <br />11. ALL NEW PARTITIONS ARE TYPE 5 ON SHEET A9-3, U.N,O. <br />12. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS SHALL <br />ACCOMMODATE FULL_ CONCEALMENT OF RECESSED CABINETS OR PARTIAL <br />CONCEALMENT OF SEMI -RECESSED CABINETS AS SPECIFIED BY THE <br />MANUFACTURER, REFER TO MOUNTING HEIGHT ON DETAIL 13 ON SHEET A7-2. <br />13. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH <br />NO VISIBLE JOINTS. .PROVIDE LEVEL 4 FINISH, U.N.O. <br />14. REFER TO MATERIAL SCHEDULE & FINISH PLAN FOR MATERIALS & LOCATIONS <br />THAT REQUIRE A LEVEL 5 FINISH, U.N.O, <br />15. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. <br />16. CONTRACTOR SHALL COORDINATE REVIEW OF THE PARTITION LAYOUT WITH <br />THE DESIGNER PRIOR TO PARTITION INSTALLATION. <br />17. CONSTRUCTION OF FIRE -RATED PARTITIONS, INCLUDING TAPING AND FINISHING <br />OF GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE, SHALL BE IN <br />ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED, <br />18. WHERE PARTITIONS EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, <br />SECURE THE TOP TRACK TO THE EXPOSED CEILING GRID, PROVIDE A <br />COMPRESSIBLE GASKET BETWEEN THE TOP TRACK AND THE CEILING GRID. <br />PROVIDE TRAPPABLE METAL J-BEAD AT TOP OF GYPSUM WALLBOARD, WITH NO <br />JOINTS VARYING MORE THAN 1/8" OVER 6-0" AND NO JOINTS GREATER THAN <br />3/16", U,N.O. CAULK PERIMETER AT TOP OF GWB, <br />19. PROVIDE GROUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR <br />SUPPORT OF CASEWORK, SHELF -STANDARDS, A/V DEVICES, FURNITURE, ETC, <br />ALL CONCEALED LUMBER AND BLOCKING TO BE FIRE TREATED, COORDINATE <br />BLOCKING REQUIREMENTS WITH FURNITURE & AV INSTALLERS. WHERE <br />BLOCKING OR ADDITIONAL STUDS ARE REQUIRED AT EXISTING PARTITIONS, <br />THEY ARE TO BE PATCHED AND REPAIRED, SEE CONSTRUCTION PLANS FOR <br />WALL -MOUNTED MILLWORK; PROVIDE BLOCKING PER MANUFACTURERS" <br />REQUIREMENTS, <br />20. PROVIDE VERTICAL CONTROL JOINTS 30' O.C. MAX. IN ALL GWB PARTITIONS <br />LONGER THAN 30'. WHEN :POSSIBLE CONTROL JOINTS SHOULD BE LOCATED <br />ABOVE THE CORNER OF A DOOR OR OPENING. <br />21. ALL HINGED DOORS TO BE 6" FROM NEAREST PERPENDICULAR PARTITION, U.N.O. <br />DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. <br />ALL DOORS SHALL HAVE V-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND <br />V-0 CLEAR ON THE STRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A <br />CLOSER) VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING <br />OUT PARTITIONS, <br />22. THE CONTRACTOR SHALL ESTABLISH A SINGLE FLOOR ELEVATION THAT IS TO BE <br />USED TO SET THE TOP OF ALL DOORS SUCH THAT THE TOP OF ALL DOORS OF <br />THE SAME HEIGHT WILL ALIGN REGARDLESS OF VARIATIONS IN THE FLOOR SLAB <br />OR FINISHED FLOOR THICKNESS. <br />23. PROVIDE DOUBLE STUDS AT DOOR JAMBS. INSTALL ADDITIONAL STUDS IN <br />EXISTING PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO PROVIDE DOUBLE <br />STUDS AT JAMBS, <br />24. PROVIDE DIAGONAL BRACING TO SLAB AT DOUBLE STUDS AT DOOR OPENINGS, <br />25. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAGE <br />(MINIMUM) @ 16" O.C, (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE <br />LOCATIONS, <br />26. GYPSUM WALLBOARD AT BOTH SIDES OF ALL PARTITIONS WITH PLUMBING <br />ROUGH -IN (E.G.BATHROOMS, BREAK AREA, MOOD ROOM) SHALL BE <br />WATER-RESISTANT. <br />27, GYPSUM WALLBOARD TO BE INSTALLED WITH NO HORIZONTAL JOINTS BETWEEN <br />THE FLOOR AND SUSPENDED CEILING. <br />Crest'Vd Crq.-n',,e Interial*S <br />Design Studio <br />o 1 th AveSouth, Suite E202 <br />Des Moines, WA 98198 <br />WWWCRESTEDCRANENTER�ORS,COM <br />OLYMPIC HOT TUB <br />811 SE EVERETT MALL WAY, SUITE <br />EVERETT, WA 98208 <br />Description: Datea No.o <br />PERMIT SET 02/15/2021 <br />NEW ENTRY DOOR REVISION 03/16/2021 <br />CONSTRUCTION KEYNOTES 010y <br />101 FINISH WALL TO A LEVEL 5 UP J-O 10' AFF IN PREP FOR TENANT PROVIDED <br />LOGO WALL COVERING, <br />1.02 FURR OUT COLUMN AND ALIGN ROOM OPENING WITH NEW COLUMN FURRING. <br />103 PROVIDE AND INSTALL THOSE BIB ADAPTER UNDER MOP SINK TUB PLUMBING, <br />104 FINISH PARTITION WITH FULL HEIGHT DRYWALL ALONG SUITE DEMISING <br />PARTITION. SEE PARTITION TYPE 7 ON SHEET A9-3, <br />105 FINISH SUITE PERIMETER PARTITION TO MEET BUILDING THERMAL ENVELOPE <br />REQUIREMENTS. <br />106 COORDINATE WITH TENANT'S OPERATIONS MANAGER FOR FINAL LOCATION <br />AND NECESSARY PREP FOR TENANT PROVIDED SUB -PANELS. <br />OPS. MANAGER: ROB ANDERSON @ (253) 227-8013. <br />107 PROVIDE AND INSTALL GROMMET WITH COVER TO ALLOW ACCESS FOR <br />WATER HOSE TO PASS THROUGH AT LOWER PORTION OF PARTITION INTO <br />MOOD ROOM. <br />108 PROVIDE AND INSTALL PANIC DOOR HARDWARE WITH OPERATION <br />INSTRUCTIONS TO COMPLY TO CURRENT CODE. <br />109 HOT TUB, 10194 E <br />➢TEOT/ <br />III REPLACE STOREFRONT WITH SAME GLAZING SIZE, UL, AND SPECIFICATIONS, <br />GENERAL CONTRACTOR TO COORDINATE WITH GLAZING VENDOR TO ENSURE <br />` U I <br />THERE ARE NO CHANGE IN HEAT GAIN/LOSS OR SURFACE AREA OF GLAZING, I a <br />sA AM E3 ➢L..k <br />TATE OF VS111 0;T0N <br />DEMOLITION & CONSTRUCTION LEGEND <br />'. <br />NOT IN CONTRACT (NIC) <br />EXISTING WALL TO REMAIN <br />= _ = EXISTING CONSTRUCTION TO BE REMOVED <br />NEW CONSTRUCTION PER DETAIL 1/A1-1, UNO <br />NEW DOOR & FRAME <br />10 <br />ALIGN <br />roj. o.: 811—T—EVE TT <br />