Laserfiche WebLink
City of Everett,Washington Water Filter Plant- Phase 2 Capital Upgrades PDB Project <br /> Progressive Design-Build Contract I Draft Exhibit C. Phase 1 Scope of Services <br /> a. Construction sequencing and multi-party coordination plan <br /> b. Design criteria for valves, actuators, pipes, fittings, and flexible connectors as <br /> applicable <br /> c. Design criteria for valve vault(s) <br /> d. Materials and methods of installation <br /> e. Demolition concepts and plans for maintaining full operations of the Water <br /> filter Plant while avoiding the introduction of debris, dust, and any other <br /> Dewatering and shoring concepts <br /> f. Structural design calculations <br /> g. Seismic design criteria and coordination with geotechnical exploration results <br /> h. Vendor supporting information for equipment and materials <br /> 5. Old #5 line cross connect improvements design, including <br /> a. Construction sequencing and multi-party coordination plan <br /> b. Design criteria for valves, actuators, pipes, fittings, and flexible connectors as <br /> applicable <br /> c. Design criteria for valve vault <br /> d. Materials and methods of replacement/installation <br /> e. Demolition concepts and plans for maintaining full operations of the Water <br /> filter Plant while avoiding the introduction of debris, dust, and any other <br /> Dewatering and shoring concepts <br /> f. Structural design calculations <br /> g. Seismic design criteria and coordination with geotechnical exploration results <br /> h. Vendor supporting information for equipment and materials <br /> 6. Flocculation basin improvements design, including: <br /> a. Construction sequencing <br /> b. Design criteria for mixer replacement including process, mechanical, and <br /> electrical design criteria <br /> c. Design criteria for outlet channel improvements including hydraulic <br /> calculations <br /> d. Design criteria for davit crane <br /> e. Material and methods of replacement/installation <br /> f. Demolition concepts and plans for maintaining full operations of the Water <br /> filter Plant while avoiding the introduction of debris, dust, and any other <br /> Dewatering and channel isolation concepts <br /> g. Structural design calculations <br /> h. Coating/sealant and corrosion protection criteria <br /> Vendor supporting information for equipment and materials <br /> 7. Alum and polymer storage tanks replacement design, including: <br /> a. Construction sequencing <br /> b. Design criteria for chemical storage tanks, piping, level sensors, and pumps <br /> as applicable <br /> c. Design criteria for building insulation, cladding, and structural members <br /> Page 9 of 20 <br />