IMCO General Construction 5/9/2022
>
Contracts
>
10 Years Then Transfer to State Archivist
>
2023
>
IMCO General Construction 5/9/2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2022 8:45:49 AM
Creation date
5/13/2022 8:42:22 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
IMCO General Construction
Approval Date
5/9/2022
Council Approval Date
5/4/2022
End Date
4/1/2023
Department
Administration
Department Project Manager
John Nottingham
Subject / Project Title
WFP Phase 2 Capital Upgrades
Tracking Number
0003343
Total Compensation
$2,723,318.68
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett,Washington I Water Filter Plant- Phase 2 Capital Upgrades PDB Project <br /> Progressive Design-Build Contract I Draft Exhibit C. Phase 1 Scope of Services <br /> Design-Builder, advanced to 90 percent identified by the Design-Builder, advanced to <br /> completion. 90 percent completion. <br /> The Design-Builder shall submit three (3) paper copies of the draft 90 Percent Design <br /> Documents and one electronic copy in Adobe PDF and MS Word format. <br /> Deliverables: <br /> 1. Draft 90 Percent Design Package <br /> Subtask 5.3 - Final Design <br /> Design-Builder shall develop and submit a Final Design Submittal to the City. The Final Design <br /> Submittal shall include all documents, drawings and specifications required under this task. The <br /> Final Design Submittal will be checked for comment incorporation by the City. After final check <br /> of the Final Design Submittal by the City, the Final Design Submittal will be stamped and signed <br /> by the responsible engineer. At a minimum, the Final Design Submittal shall include: <br /> 1. Narrative description of revisions to the design package since the 90 percent design, <br /> and rationale for changes <br /> 2. Summary of status of any applicable permits <br /> 3. Updated Phase 2 cost model based on final design <br /> 4. Updated Phase 2 schedule based on final design <br /> 5. Updated Design and Construction Phasing Plan, including plans for procurement of <br /> any long-lead items. Include a brief narrative describing changes to the Plan (if any) <br /> from the 90 percent submittal. <br /> 6. All internal QA/QC Review documentation, including signature pages documenting <br /> completed reviews, and if requested by the City, reviewer comments and design <br /> team responses. <br /> 7. Plans and specifications consistent with issuance for construction, including at a <br /> minimum the items identified in Table 3. <br /> Table 3. Final Drawings and Specifications — Minimum Requirements <br /> Drawings Specifications <br /> All drawings included in 90 percent submittal, All specifications included in 90 percent <br /> and any additional drawings identified by the submittal, and any additional specifications <br /> Design-Builder, advanced to final design identified by the Design-Builder, advanced to <br /> completion. final design completion. <br /> The Design-Builder shall submit one full-sized set of the stamped and signed Final Design <br /> Documents and one electronic copy in Adobe PDF and MS Word format. Wet signatures are not <br /> required for the full-size submittal, a printed copy is acceptable. <br /> Page 14 of 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.