My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2818 HOYT AVE FRATERNAL ORDER OF EAGLES 2022-05-23
>
Address Records
>
HOYT AVE
>
2818
>
FRATERNAL ORDER OF EAGLES
>
2818 HOYT AVE FRATERNAL ORDER OF EAGLES 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 2:47:04 PM
Creation date
5/23/2022 2:46:08 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2818
Tenant Name
FRATERNAL ORDER OF EAGLES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c. The beams should be evaluated for unsupported lengthse u pp q no the clear spans. Lateral <br /> support by the existing structure is not permitted unless it is provided in such a way to <br /> prevent the transfer of vertical loads per the previous comment. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> d. The support walls and bracing should be provided in both orthogonal directions. Wall appear <br /> to be provided in only one direction per Detail A/S2. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> e. Continuing with the previous comment, the beams should be designed for lateral and vertical <br /> seismic loads concurrently with the gravity loads. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> f. The structural drawings do not appear to include connections details to the existing walls. <br /> Details should be included in the drawings. Calculations substantiating the connection design <br /> should be submitted for review. The connection design should consider concurrent vertical <br /> and lateral seismic loads with the gravity loads. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> g. The vertical framing supporting each ends of the beams should be clearly defined in the <br /> structural drawings. Calculations substantiating the capacity of the supports, including <br /> existing loads where existing framing is utilized, should be submitted for review. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> h. Supplemental framing to support the existing roof sheathing at the duct penetrations should <br /> be provided. The supplemental framing should allow independent vertical movement. <br /> All architectural/structural items to be addressed in submittal documents in building permit <br /> application B2103-046. <br /> 7. Mechanical units are located on sloped roofs and may require access platforms and guards for <br /> maintenance per IMC Section 306.5.1. The slope of the roof should be specified. If a platform is <br /> required, this work should be included as part of the building permit unless it is integral constructed <br /> as part of the mechanical equipment. <br /> All architectural/structural items to be addressed in submittal documents in building permit application <br /> B2103-046. <br /> Sincerely, <br /> Austin Rapp, B.S. M.E David Bradley,P.E. <br /> Ph. (360) 325-2515 Ph. (360) 752-5795 <br />
The URL can be used to link to this page
Your browser does not support the video tag.