My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2823 HOYT AVE EVERPARK GATEWAY GARAGE 2022-05-23
>
Address Records
>
HOYT AVE
>
2823
>
EVERPARK GATEWAY GARAGE
>
2823 HOYT AVE EVERPARK GATEWAY GARAGE 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 2:56:08 PM
Creation date
5/23/2022 2:55:40 PM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2823
Tenant Name
EVERPARK GATEWAY GARAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Ruben Sanchez <br /> City of Everett <br /> Plan Check Number: B1812-022, First Building Review <br /> January 14, 2019 <br /> Gravity System: <br /> 5. Detail 19/S.10 specifies individual repairs for both the concrete columns and prestressed <br /> girder ends. It is unclear if the proposed work is repairing structural damage or is intended <br /> to prevent future damage. If the former, structural calculations substantiating the proposed <br /> repair shall be submitted for review. See IEBC Section 606.2.3 and IBC Section 1604.1. <br /> 6. Continuing with the previous comment, the"Design Strength" paragraph in the <br /> "Renovation"section of the General Structural Notes on Sheet SO.0 states that the FRP <br /> system shall be designed for the"total strength and confinement"requirements specified in <br /> the drawings. Performance and load requirements for the design of the FRP repairs do not <br /> appear to be provided. The structural drawings shall be revised to specify the required <br /> criteria. The mechanism(s) for each load shall be specified (e.g., column compression, <br /> corbel moments, girder shear, prestressed endzone anchorage, etc.). See IBC Section <br /> 1603.1.8. <br /> 7. Detail 19/S.10 specifies a minimum repair length of 4'-6"from the girder end, which must <br /> wrap around the bottom of the girder per Detail 14/S.10. The girder bearing connection <br /> prevents wrapping the beam underside for at least one-half of the corbel depth. Verify the <br /> required length of the repair. See IBC Section 107.2.1. <br /> 8. Detail 18/S.10 specifies repair of the embedded bearing plates in the deck girder ends. The <br /> repair appears to require removal of concrete between the girder end and the plate, which <br /> may induce unintended stresses in the plate (e.g., flexure, pryout loads on embedded <br /> elements, etc.). See IBC Sections 1603.1, 1604.1, and 1604.4. The following comments <br /> shall be addressed: <br /> a. Calculations shall be submitted substantiating that the temporary construction condition <br /> of the bearing assembly is adequate for the proposed repair. Detail 18/S.10 shall be <br /> revised to specify the maximum amount of material that may be removed without <br /> destabilizing the assembly. <br /> b. Alternatively, details for a shoring system shall be specified in the structural drawings; <br /> calculations substantiating the system shall be provided. Where the temporary shoring <br /> is deferred for design by the contractor, the shoring system shall be included in the list <br /> of Deferred Submittals on Sheet SO.0; performance requirements shall be specified per <br /> IBC Section 1603.1.8. <br /> c. The shoring system shall be included in the Special Inspection Schedule on Sheet SO.0 <br /> per IBC Section 1705.1.1. <br /> d. The drawings shall specify temporary construction conditions as needed (e.g., no vehicle <br /> load on the parking deck during repairs, etc.). See IBC Section 107.2.1 <br /> 9. Detail 16/S.10 specifies replacement of the vertical support connection for precast panels. <br /> The following comments shall be addressed: <br /> a. Calculations substantiating the design of the connection shall be submitted for review. <br /> See IBC Section 1604.1. <br /> b. Specify shoring requirements as needed for the panel. Shoring requirements shall be <br /> similar to those stated in Comment 8 above. Where shoring is not provided, calculations <br /> shall substantiate the remaining connections are adequate for the temporary condition. <br /> 0 3200 Cedar Street CD 425.257.8800 0 everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br /> L1 I s <br />
The URL can be used to link to this page
Your browser does not support the video tag.