• <br /> Mr. Ruben Sanchez <br /> City of Everett <br /> Plan Check Number: B1812-022, Second Building Review <br /> March 19, 2019 <br /> 4. This comment has not been completely addressed. Sheet A1.11 shows new accessible <br /> spaces on both sides of the elevator core. See IBC Section 1101.2 and Comment 3 above <br /> for additional information The following comments shall be addressed: <br /> a. The boundary of the spaces immediately adjacent to the core is not defined. Striping <br /> consistent with Detail E4/A1.11 shall be shown to confirm that the required minimum <br /> dimensions are provided. See 107.2.1. <br /> b. No additional comment. <br /> c. The locations of the van-accessible spaces shall be specified on the plans. <br /> 5. This comment has not been addressed. The original comment stated that Detail E4/A1.11 <br /> specifies the access aisle on the driver-side of the van-accessible parking space instead of <br /> the passenger-side as required for angled parking spaces. The detail has been revised to <br /> eliminate the van-accessible space. However, striping for van-accessible spaces is required <br /> per Comment 3 above. The detail shall be revised as stated in the original comment. See <br /> IBC Section 1101.2 and ICC A117.1-09 Section 502.4.1. <br /> 6. This comment has not been addressed. See Comment 3 above. Accessible parking spaces <br /> shall be provided with signage per IBC Section 1111.1. The signs shall comply with ICC <br /> A117.1-09 Section 502.7, including additional requirements for van-accessible spaces. <br /> Details specifying the requirements for the signs shall be provided. Note that the <br /> requirements to provide signs are not exempt where painted accessible symbols per Detail <br /> E2/A1.11 are provided on the parking surface. See IBC Section 1101.2. <br /> Additional Comments: <br /> 7. The submitted revised architectural drawings are not scaled correctly. In addition, the <br /> relative size of the plans and details with the same stated scale are not consistent. Note <br /> also that the accessible paths shown on the plan, notably those located between the spaces, <br /> appear inconsistent with Detail E4/A1.11. Revised plans with the correct scales and layouts <br /> shall be submitted. See IBC Section 107.2.1. <br /> Structural <br /> General: <br /> 1. No additional comment. <br /> 2. This comment has not been completely addressed. The note and comment responses <br /> appear to indicate that the proposed work qualifies as a repair. The"Codes" portion of the <br /> General Structural Notes shall specify that the work has been performed per Chapter 6 of <br /> the IEBC. See IEBC Section 502. <br /> 3. This comment has not been completely addressed. The requirement shall state that the <br /> conformance review shall be performed by the Engineer-of-Record. See IBC Section <br /> 107.3.4.1. <br /> 4. No additional comment. <br /> © 3200 Cedar Street G <br /> 425.257.8800 0 everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br /> 3 /5 <br />