Capital Architects Group pc <br /> 2813 Rockefeller Ave.Everett,WA 98201•ph:425.317.8017•fax:425.317.8489 <br /> A <br /> f-- <br /> 3) The preexisting condition of the basement level is an unpermitted unoccupied or storage area.The following <br /> comments shall be addressed: <br /> a. Documentation establishing the preexisting condition of this space shall be submitted for review.The <br /> preexisting condition shall be stated in the"Project Data"section on Sheet A-1.0.See IBC Section 302.1. <br /> b. The floor-to-floor height of the basement level is 7"-6"per Section 1/A-3.0,with an estimated net clear <br /> height to the basement ceiling of 6'-0"maximum.The space does not have sufficient clearance to be <br /> permitted as occupied space.The design shall be revised.See IBC Section 1208.2. <br /> c. The construction of the space shall comply with all requirements of the building code for new construction. <br /> The design shall be revised.See IBC Sections 101.2 and 101.3. <br /> Response: <br /> The basement is not a preexisting condition of unpermitted unoccupied or storage area.The <br /> basement was in fact an apartment-with its own entrance.We attach the-following documentation:1. 6.23.1926 Original Construction Water Permit for Duplex House <br /> 2. 7.31.1961 Application for meters for 3 Apartments <br /> 3. 12.11.88 Application for Variance Professional Offices <br /> 4. 2.21.89 Interior Remodel for Professional office Space <br /> 5. 5.4.89 Use Permit convert triplex into professional Office <br /> IEBC 101.4.2 Buildings previously occupied states"The legal occupancy of any building existing on <br /> the date of adoption of this code shall be permitted to continue without change except as is <br /> specifically covered in this code,the international Fire Code,or the international Property <br /> Maintenance Code,or as is deemed necessary by the code official for the general safety and <br /> welfare of the occupants and the public." <br /> Therefore,our response is as follows: <br /> a. Documentation is attached,namely, <br /> 1. 6.23.1926 Original Construction Water Permit for Duplex House <br /> 2. 7.31.1961 Application for meters for 3 Apartments <br /> 3. 12.11.88 Application for Variance Professional Offices <br /> 4. 2.21.89 Interior Remodel for Professional office Space <br /> 5. 5.4.89 Use Permit convert triplex into professional Office <br /> IBC Section 302.1 General states:Structures or portions of structures shall be classified <br /> with respect to occupancy in one or more of the groups listed in this section..." If you are suggesting <br /> that the entire Triplex was not included in the change of use from Triplex to professional office, <br /> then that must leave us with 1 level Residential and 2 levels of Professional Office. Contrary to this <br /> line of possible thought,the application for construction permit on 2.21.89 explicitly states" <br /> interior remodel change of use residential to office.The Code reference to IBC Section 302.1 <br /> confirms that Business is Group B. <br /> b. The floor to Floor height of the basement level is 7'6"per Section 1/A-3.0,with an estimated net clear <br /> height to the basement ceiling of 6'0"maximum. The space does not have sufficient clearance to be <br /> permitted as occupied space. The design shall be revised. See IBC Section 1208.2. <br /> Response: Floor to floor heights are grandfathered in. The space is currently a permitted occupied <br /> space of professional office. <br /> c. The construction of the space shall comply with all requirements of the building code for new construction. <br /> The design shall be revised. See IBC Sections 101.2 and 101.3. <br /> Response: The Construction of the space shall comply with the IEBC and the IBC.Per the IEBC, <br /> Section 101.2 Scope"The provisions of the International Existing Building Code shall apply to the <br /> repair,alteration,change of occupancy,addition to and relocation of existing buildings. See also <br /> Section 101.4.2 Buildings previously occupied:The legal occupancy of any building existing on the <br /> date of adoption of this code shall be permitted to continue without change,except as is specifically <br /> covered in this code,the International Fire Code,or the International Property Maintenance Code,or <br /> as is deemed necessary by the code official for the general safety and welfare of the occupants and <br /> the public." <br /> Per IBC Section 101.3 Our scope of work falls under the definition of Repair: "The reconstruction or <br /> renewal of any part of an existing building for the purpose of its maintenance or to correct damage." <br />