NOM T <br />1.5 T <br />1.5 T <br />1.5 T <br />1.5 T <br />-P wo''Jul "im <br />TAG <br />MAKE AND MODEL <br />LOCATION <br />DESCRIPTION <br />AIRFLOW <br />(CFM) <br />COOLING PERFORMANCE <br />HEATING PERFORMANCE <br />R-410A PIPING <br />MAX SOUND <br />(dBA) <br />CONTROL <br />TYPE <br />FILTRATION <br />TYPE <br />60HZ ELEC DATA <br />VOLTS PH FLA MCA MOCP <br />WEIGHT <br />(LDS) <br />NOTES: <br />TOTAL <br />(MBH) <br />SENS <br />(MBH) <br />SEER <br />EER <br />(MBH) <br />HSPF <br />ACC ELEC <br />(KW) <br />LIQ <br />(IN) <br />GAS <br />(IN) <br />MAX LENGTH <br />(FEET) <br />AH--1 <br />CARRIER 40MAQB18B®3 <br />ELEV MACH RM 103.2 <br />FAN COIL <br />660 <br />16.8 <br />17.0 <br />20.0 <br />12.5 <br />18.0 <br />10.3.2 <br />m <br />1/4 <br />1/2 <br />96 <br />46.0 <br />WIRED <br />NONE <br />POWERED FROM HP-1 <br />27 <br />HP®1 <br />CARRIER 36MAQB1 8R®3 <br />ROOF <br />CONDENSING UNIT <br />57.5 <br />203/230 <br />1 <br />1 �.0 <br />25 <br />1119 <br />11 2, 3, 42 51 6, 7, 81 9, 10, 11, 12 <br />AH®2 <br />CARRIER 40MAQB16Bm3 <br />MEDICATION 130 <br />DUCTLESS FAN COIL <br />660 <br />16.6 <br />17.0 <br />20.0 <br />12.5 <br />18.0 <br />10.3.2 <br />- <br />1 /4 <br />1 /2 <br />98 <br />46.0 <br />WIRED <br />NONE <br />POWERED FROM HP-2 <br />27 <br />HP-2 <br />CARRIER 38MAQB18R-3 <br />ROOF <br />CONDENSING UNIT <br />57.5 <br />203/230 <br />1 <br />- <br />18.0 <br />25 <br />'119 <br />1, 2, 3, 4, 5, 6, 7, S, 9, 10, 11, 12 <br />AH®3 <br />CARRIER 40MAQB16B--3 <br />MEDICATION 173 <br />FAN COIL <br />680 <br />16.6 <br />17.0 <br />20.0 <br />12.5 <br />16.0 <br />10.3.2 <br />1 /4 <br />1 /2 <br />98 <br />46.0 <br />WIRED <br />NONE <br />POWERED FROM HP®3 <br />27 <br />HP-3 <br />CARRIER 38MAQB1 8R-3 <br />ROOF <br />CONDENSING UNIT <br />57.5 <br />20B/230 <br />1 <br />1 �.0 <br />25 <br />119 <br />, 2, 3, 5, 7 <br />14, 6, , S, 91 10, 11, 12 <br />AH-4 <br />CARRIER 40MAQB1 8B-3 <br />COM 174 <br />FAN COIL <br />660 <br />16.6 <br />17,0 <br />20.0 <br />12.5 <br />18.0 <br />10.3.2 <br />1 /4 <br />1 /2 <br />98 <br />46.0 <br />WIRED <br />NONE <br />POWERED FROM HP-4 <br />27 <br />HP-4 <br />CARRIER 38MAQB16R®3 <br />ROOF <br />CONDENSING UNIT <br />57.5 <br />119 <br />1, 2, <br />3, 4, 5, 6, 7, $, 9, 10, 11, 12 <br />NOTES: <br />1. EQUIPMENT MAY BE SUBSTITUTED, REFER TO APPROVED EQUIPMENT DATA SHEETS/SUBMITTALS FOR FINAL SELECTIONS. <br />2. REFER TO ELECTRICAL DRAWINGS FOR DISCONNECT, EMERGENCY POWER PROVISIONS AND POWERED CONVENIENCE OUTLET, AS APPLICABLE. <br />3. ALL ELECTRICAL WORK BY ELECTRICAL CONTRACTOR UNDER SEPARATE PERMIT. <br />4, INCLUDES SINGLE POINT ELECTRICAL CONNECTION: INDOOR UNITS ARE POWERED FROM OUTDOOR UNITS. <br />5. LISTED EQUIPMENT RATING CONDITIONS ARE PER AHRI STANDARD. FAN COIL UNITS PROVIDED WITH MULTI -SPEED AIRFLOW CONTROLS. <br />6. PROVIDE WITH MANUFACTURER'S OPTIONAL WIRED WALL MOUNTED PROGRAMMABLE CONTROLLER (7 DAY, DIGITAL PROGRAMMABLE THERMOSTAT). <br />7. PROVIDE WITH CONDENSATE DRAIN PUMP, AS NEEDED, CONDENSATE PIPING TO DE INSTALLED BY PLUMBING CONTRACTOR AND SHALL DRAIN TO AN APPROVED LOCATION. <br />6. SOUND PRESSURE LEVEL IS FOR BOTH COOLING AND HEATING AT MAX FAN AIRFLOW CONDITIONS. <br />9. PROVIDE WITH NEW R410A REFRIGERANT PIPING BETWEEN CONDENSER AND EVAPORATOR PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />10. PROVIDE OUTDOOR HEAT PUMP UNITS WITH LOCKING REFRIGERANT ACCESS PORT CAPS PER THE REQUIREMENTS OF THE 2015 IMC SECTION 1101.10. <br />11. SYSTEM SHALL BE AVAILABLE FOR CONTINUOUS OPERATION (24x7). <br />12. NO AIR SIDE ECONOMIZER IS PROVIDED AS ALLOWED BY THE 2015 WSEC SECTION C403.3, EXCEPTION 10, AND TABLE C403.3(10) OPTION A, QUALIFYING EQUIPMENT. <br />INDOOR FAN PERFORMANCE UNIT COOLING CAPACITY MEDIUM HEATING CAPACITY - NATURAL GAS ELECTRICAL DATA (60 HZ) WEIGHTS <br />NOM MIN OSA FILTRATION SOUND <br />TONS (CFM) SA ESP FAN TOTAL SENSIBLE pRl INPUT OUTPUT THERMAL CONN SIZE DISPOSABLE VOLTS PHASE MCA MOCP RATING BASE TOTAL <br />TAG MANUFACTURER - MODEL DESCRIPTION LOCATION APPLICATION (CFM) (IN WG) DRIVE (BHP) (MBH) (MBH) EER (MBH) (MBH) ELF (INCHES 4) (# / SIZE) �V) (�) (A) (A) (LW) (LBS) (LBS) NOTES: <br />RTU®1 <br />CARRIER <br />48LCDB17B3A6m 1 POAO <br />15-TON GAS/DX <br />ROOFTOP UNIT <br />LOWER ROOF <br />L1 SPACE <br />CONDITIONING <br />15.0 <br />1,030 <br />5,134 <br />1.9 <br />DIR <br />ECM <br />4.42 <br />161.7 <br />136.7 <br />12.5 <br />220.0 <br />178.0 <br />S 1 <br />0.75" <br />(10) 20x24x2 <br />460 <br />3 <br />51.1 <br />60 <br />6$.3 <br />2,492 <br />3,356 <br />1®-9 <br />RTU-2 <br />CARRIER <br />20®TON GAS/DX <br />LOWER ROOF <br />L1 SPACE <br />20 0 <br />1,300 <br />6,463 <br />2.0 <br />DIR <br />5.40 <br />242.6 <br />173.9 <br />10.1 <br />350.0 <br />263.5 <br />61 % <br />1.5" <br />(10) 20x24x2 <br />460 <br />3 <br />64 <br />70 <br />90.5 <br />4,551 <br />5,373 <br />1®9 <br />48A3SO20KLM64AHH <br />ROOFTOP UNIT <br />CONDITIONING <br />ECM <br />RTU®3 <br />CARRIER <br />`I 54-TON GAS/DX <br />UPPER ROOF <br />L2 SPACE <br />15.0 <br />1,030 <br />5,134 <br />1.9 <br />DIR <br />4.42 <br />161.7 <br />136.7 <br />12.5 <br />220.0 <br />176.0 <br />61 % <br />0.75" <br />(10) 20x24x2 <br />460 <br />3 <br />51.1 <br />60 <br />$6.3 <br />2,492 <br />3,386 <br />1-9 <br />®1 P <br />LC DB 7B3 A6 OAO <br />ROOFTOP UNIT <br />CONDITIONING <br />ECM <br />NOTES: <br />1. <br />EQUIPMENT MAY BE SUBSTITUTED FOR <br />EQUAL OR OTHER APPROVED MANUFACTURER OR MODEL. NOT ALL <br />MANUFACTURER'S OPTIONS AND EXTENDED MODEL NUMBERS ARE SHOWN IN THE SCHEDULE. REFER TO EQUIPMENT SUBMITTALS FOR FINAL SELECTIONS. <br />- <br />2. <br />REFER TO ELECTRICAL DRAWINGS FOR <br />DISCONNECT AND POWERED CONVENIENCE OUTLET, AS APPLICABLE. <br />3. <br />PROVIDE UNIT <br />WITH 14" ROOF CURB. <br />LISTED OPERATING WEIGHTS INCLUDE BASE UNIT + ACCESSORIES + <br />CURB. <br />4. <br />PROVIDE UNIT <br />WITH MANUFACTURER'S <br />INTEGRATED OUTSIDE AIR ECONOMIZER, WSEC COMPLIANT LOW LEAK <br />DAMPERS AND FAULT DETECTION AND DIAGNOSTICS (FDD) WITH INTEGRATED DRY BULB TEMPERATURE MODULATING ECONOMIZER CONTROL. <br />5. <br />PROVIDE UNIT <br />WITH MANUFACTURER'S <br />MEDIUM STATIC INDOOR, DIRECT DRIVE FAN WITH ELECTRONICALLY COMMUTATED MOTOR (EC MOTOR). <br />6. <br />PROVIDE UNIT <br />WITH PACKAGED ELECTROMECHANICAL <br />PROGRAMMABLE CONTROLS AND 7-DAY T®STAT. REFERENCE RELATED FLOOR PLANS FOR THERMOSTAT LOCATION AND ADA MOUNTING HEIGHT. ROOFTOP UNIT RUNS PER OCCUPANCY SCHEDULE OF TENANT SPACE AS DETERMINED BY OWNER. <br />7. <br />PROVIDE UNIT <br />WITH MANUFACTURER'S <br />OPTIONAL RETURN AIR SMOKE DETECTOR, FULL ELECTROMECHANICAL <br />CONTROLS, ECONOMIZER CONTROLLER WITH FDD AND BAROMETRIC RELIEF. <br />8. <br />FAN MOTORS <br />ARE TO BE SMALLEST SIZE <br />AVAILABLE TO COVER THE BHP REQUIREMENT. <br />9. <br />PROVIDE MODULATING COMBUSTION CONTROLS. <br />DESIGNED <br />CSUSA NW / SL i EE <br />CHECKED <br />CSUSA NW / SL I EE <br />DATE <br />7-24-2020 <br />SHEET TITLE <br />