SERIES FAN POWERED TERMINAL UNIT SCHEDULE <br />MINIMUM <br />MAXIMUM <br />INLET <br />FAN PERFORMANCE <br />ELECTRIC HEATER PERFORMANCE <br />PRIMARY AIR <br />PRIMARY AIR <br />SIZE <br />MAX <br />ECM <br />ECM <br />60 HERTZ <br />MAX <br />WEIGHT <br />TAG <br />MAKE & MODEL <br />UNIT SIZE <br />DESCRIPTION <br />SERVES <br />(CFM) <br />(CFM) <br />(INCHES) <br />CFM <br />HP <br />FLA <br />VOLTS PHASE <br />Kul <br />STAGES <br />VOLTS <br />PH <br />AMPS <br />MOCP <br />CONTROL <br />NOTES <br />FPTU-1 <br />NAILOR D35SE <br />2 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />335 <br />335 <br />2 <br />6"0 <br />335 <br />VAR <br />2.6 <br />277/1 <br />3.7 <br />2 <br />460/3 <br />4.7 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-2 <br />NAIL OR D35SE <br />2 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />410 <br />410 <br />2 <br />6"0 <br />410 <br />VAR <br />2.6 <br />277/1 <br />4.5 <br />2 <br />460/3 <br />5.7 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-3 <br />NAILOR D35SE <br />4 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />610 <br />610 <br />4 <br />10"o <br />610 <br />VAR <br />4.2 <br />277/1 <br />6.8 <br />2 <br />460/3 <br />--6.5 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-4 <br />NAILOR D35SE <br />5 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />950 <br />950 <br />5 <br />12"0 <br />950 <br />VAR <br />5.6 <br />277/1 <br />10.5 <br />2 <br />460/3 <br />13.2 <br />20 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-5 <br />NAILOR D35SE <br />4 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />750 <br />750 <br />4 <br />10"o <br />750 <br />VAR <br />4.2 <br />1 277/1 <br />3.3 <br />2 <br />460/3 <br />10.4 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-6 <br />NAILOR D35SE <br />2 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />300 <br />300 <br />2 <br />6"0 <br />300 <br />VAR <br />2.6 <br />277/1 <br />3.3 <br />2 <br />460/3 <br />4.2 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-7 <br />NAILOR D35SE <br />4 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />600 <br />600 <br />4 <br />10"o <br />600 <br />VAR <br />4.2 <br />277/1 <br />6.6 <br />2 <br />460/3 <br />6.4 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU®6 <br />NAILOR 035SE <br />2 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />500 <br />500 <br />2 <br />6"0 <br />500 <br />VAR <br />2.6 <br />277/1 <br />5.5 <br />2 <br />460/3 <br />7.0 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-9 <br />NAILOR D35SE <br />5 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />975 <br />975 <br />5 <br />12"0 <br />975 <br />VAR <br />5.8 <br />277/1 <br />10,6 <br />2 <br />460/3 <br />13.6 <br />20 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU10 <br />NAILOR D35SE <br />4 <br />VARIABLE VOLUME <br />LEVEL 1 EXTERIOR ZONES <br />750 <br />750 <br />4 <br />10"o <br />750 <br />VAR <br />4.2 <br />277/1 <br />8.3 <br />2 <br />460/3 <br />10.4 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-11 <br />NAILOR D35SE <br />4 _ <br />VARIABLE VOLUME <br />LEVEL 2 EXTERIOR ZONES <br />735 <br />735 <br />4 <br />10"o <br />735 <br />VAR <br />4.2 <br />277/1 <br />6.1 <br />2 <br />460/3 <br />10.2 <br />15 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-12 <br />NAILOR D35SE <br />2 <br />VARIABLE VOLUME <br />LEVEL 2 EXTERIOR ZONES <br />375 <br />375 <br />2 <br />62)0 <br />375 <br />VAR <br />2.6 <br />277/1 <br />6.4 <br />2 <br />460/3 <br />8.0 <br />15 <br /><200_ <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU-13 <br />NAILOR D35SE <br />5 <br />VARIABLE VOLUME <br />LEVEL 2 EXTERIOR ZONES <br />950 <br />950 <br />5 <br />12"0 <br />950 <br />VAR <br />5.6 <br />277/1 <br />10.5 <br />2 <br />460/3 <br />13.2 <br />20 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />FPTU— 14 <br />NAILOR D35SE <br />4 <br />VARIABLE VOLUME <br />LEVEL 2 EXTERIOR ZONES <br />750 <br />750 <br />4 <br />10" o <br />750 <br />VAR <br />4.2 <br />277/1 <br />&3 <br />2 <br />460/3 <br />10.4 <br />20 <br /><200 <br />DIGITAL <br />1, 2, 3, 4 <br />NOTES: <br />1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR <br />BETTER MANUFACTURER. <br />2. FAN POWERED TERMINAL UNITS ARE SERIES CONFIGURED <br />AND SERVE EXTERNAL ZONES ONLY. <br />3. HEATER SIZING BASED ON A AT-357. <br />4. PROVIDE ALL EXHAUST FANS WITH 70% OR GREATER <br />EFFICIENCY MOTORS OR ELECTRONICALLY COMMUTATED (ECM) <br />MOTORS AS REQUIRED BY 2015 WSEC SECTION C405.8 <br />FOR FRACTIONAL HORSEPOWER FAN MOTORS THAT ARE <br />1/12 HORSEPOWER AND LARGER. <br />GAS PRV SCHEDULE <br />EXHAUST FAN SCHEDULE <br />INLET PRESS <br />OUTLET PRESS <br />PRV MAX <br />INDIV LOAD <br />CONK <br />FAN PERFORMANCE <br />ELECTRICAL DATA (60 HZ) <br />- <br />TAG <br />MFR / MODEL <br />SERVES_ <br />DESCRIPTION <br />(PSIG) <br />(IN W.C.) <br />CAP (MBH) <br />(MBTUH) <br />SIZE <br />(IN) <br />NOTES <br />- - <br />PRV-1 <br />MAXITROL — 5L <br />RTU-1 <br />NATURAL GASI <br />2# <br />14" <br />425 <br />220 <br />3/4" <br />1 <br />FLOW <br />ESP <br />FAN <br />DRIVE <br />MOTOR <br />VOLTS <br />PHASE <br />FLA <br />MOCP <br />SOUND <br />WEIGHT <br />TAG <br />MANUFACTURER AND MODEL <br />DESCRIPTION <br />APPLICATION <br />(CFM) <br />(IN WG) <br />RPM <br />(HP) <br />- <br />(dBA) <br />(LBS) <br />NOTES: <br />PRV-2 <br />MAXITROL — 5L <br />RTU-2 <br />NATURAL GAS <br />2 <br />14" <br />425 <br />220 <br />3/4" <br />1 <br />EF-1 <br />GREENHECK G-060—VG <br />ROOFTOP <br />EXHAUST <br />TOILET <br />ROOM EXHAUST <br />250 <br />0.5 <br />1,630 <br />DIRECT <br />0.1 <br />115 <br />1 <br />1.3� <br />15.0 <br />55 <br />2S <br />1 2 4 6 7 <br />- <br />PRV-3 <br />MAXITROL e 5L <br />RTU-3 <br />NATURAL GAS <br />2# <br />14" <br />425 <br />350 <br />3/4'y <br />1 <br />EF-2 <br />GREENHECK G-090�-VG <br />ROOFTOP <br />EXHAUST <br />TOILET <br />ROOM EXHAUST <br />350 <br />0.5 <br />1> 429 <br />DIRECT <br />0.1 <br />115 <br />1 <br />1.35 <br />15.0 <br />52 <br />29 <br />2 39 4S 6 7 <br />1' <br />PRV-4 <br />MAXITROL — 3L <br />GWH— 1 <br />NATURAL GAS <br />2# <br />14" <br />140 <br />76 <br />1 /2" <br />1, <br />2 <br />- <br />Y 8 <br />EF-3 <br />GREENHECK G-099—VG <br />ROOFTOP <br />EXHAUST <br />TOILET <br />ROOM EXHAUST <br />750 <br />0.7 <br />1,510 <br />DIRECT <br />0.25 <br />115 <br />1 <br />2.65 <br />15.0 <br />59 <br />36 <br />1, 2, 3, 4, 6, 7 <br />EF-4 <br />GREENHECK G-090—VG <br />ROOFTOP <br />EXHAUST <br />BREAK <br />ROOM EXHAUST <br />350 <br />0.5 <br />i ,429 <br />DIRECT <br />0.1 <br />115 <br />1 <br />1.36 <br />15,0 <br />52 <br />29 <br />1, 2, 3, 5, 6, 7 <br />NOTES: <br />TOTAL GAS LOAD <br />= 666,000 <br />BTUH (617 CFH) <br />7 <br />- <br />1. VALVES MAY BE SUBSTITUTED. REFER TO APPROVED EQUIPMENT SUBMITTALS FOR FINAL SELECTIONS. <br />2. VALVE IS NOT VENTED BUT RATHER FITTED WITH A VENT LIMITER PROVIDED BY THE MANUFACTURER, MAXITROL <br />12AO9. <br />NOTES: <br />1. <br />EQUIPMENT MAY BE SUBSTITUTED, REFER TO APPROVED <br />EQUIPMENT <br />SUBMITTALS <br />FOR FINAL SELECTIONS. <br />2. <br />REFER TO ELECTRICAL DRAWINGS FOR MOTOR STARTER, <br />DISCONNECT, <br />AND POWERED CONVENIENCE OUTLET, AS APPLICABLE. <br />3. <br />PROVIDE EQUIPMENT SUPPORT SLEEPERS, GREENHECK GESS OR EQUAL. <br />4. <br />UNIT AVAILABLE FOR 24/7 OPERATION AND CONTROLLED <br />VIA AN OCCUPANCY TIMER, ADJUSTABLE BY THE OWNER. <br />5. <br />FAN TO BE ACTIVATED BY WALL SWITCH WITH LABEL AT <br />THE SWITCH <br />INDICATING <br />IT CONTROLS THE EXHAUST FAN. <br />6. <br />PROVIDE WITH CLASS 1 LOW LEAK MOTORIZED DAMPER <br />AND TWO POSITION ACTUATOR AT BUILDING ENVELOPE EXHAUST DUCT PENETRATION PER 2015 WSEC <br />C403.2.4.3. <br />7. <br />PROVIDE ALL EXHAUST FANS WITH 70% OR GREATER EFFICIENCY MOTORS <br />OR ELECTRONICALLY COMMUTATED (ECM) MOTORS AS REQUIRED BY 2015 WSEC SECTION C405.6 <br />FOR FRACTIONAL HORSEPOWER FAN MOTORS THAT ARE <br />1 /12 HORSEPOWER AND <br />LARGER, <br />HVAC DUCT SPECIFICATION SCHEDULE <br />HVAC DUCT SPECIFICATION NOTES: <br />1. <br />ALL DUCTWORK TO CONSTRUCTED TO 2015 IMC REQUIREMENTS, <br />SMACNA SEAL CLASS A STANDARDS, ALL TRANSVERSE JOINT, <br />DUCT SYSTEM <br />SMACNA PRESSURE <br />MATERIALS <br />CLEANLINESS <br />AND USE <br />SEISMIC <br />NOTES: <br />LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS TO BE SEALED. <br />OR SECTION <br />CLASS <br />(DUCT, LINING, INSULATION) <br />DURING <br />CONSTRUCTION <br />HVAC SUPPLY <br />LOW PRESSURE <br />GALVANIZED METAL DUCT <br />FOLLOW BASIC <br />LEVEL <br />A SMACNA CLEANLINESS GUIDELINES. <br />APPROVAL OF <br />1, 2, 3, <br />4, <br />2. <br />DUCT WORK SHALL BE INSULATED AND PROVIDED WITH VAPOR BARRIER <br />ATTACHMENTS TO <br />5 <br />AS REQUIRED BY 2015 WSEC SECTION C403.2.8 AND AS FOLLOWS: <br />HEATING AND COOLING <br />SP :� 2" WG, RTU TO DIFFUSERS <br />ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS <br />AND DUCT <br />ONLY OK TO USE TEMPORARY HEAT AND VENTILATION WITH <br />STRUCTURE BY OTHERS <br />WALL PENETRATIONS SEALED TO SMACNA SEAL <br />CUSS A. <br />CONSTRUCTION <br />FILTER <br />INSTALLED <br />AND UNIT IN 100% OSA <br />TYPE LOCATION R—VALUE <br />MAINS <1500 FPM. BRANCHES <br /><1200 <br />MODE, <br />OS AIR >2500 CFM IN CONDITIONED SPACE 19 <br />FPM. BRANCH TO DIFFUSER <br /><600 FPM <br />INSULATION PER NOTE 2 <br />OS AIR <2800 CFM IN CONDITIONED SPACE 7 <br />SUPPLY OR RETURN IN UNCONDITIONED SPACE 6 <br />HVAC RETURN <br />LOW PRESSURE <br />GALVANIZED METAL DUCT <br />FOLLOW BASIC <br />LEVEL <br />A SMACNA CLEANLINESS GUIDELINES. <br />APPROVAL OF <br />1, 2, 3, <br />4, <br />SUPPLY OF RETURN OUTSIDE BUILDING <br />[1 ] <br />ATTACHMENTS TO <br />5 <br />HEATING AND COOLING <br />SP < 2" WG, RETURN TO <br />RTU <br />ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS <br />AND DUCT <br />RELIEVE AIR THROUGH <br />DOORS AND WINDOWS <br />STRUCTURE BY OTHERS <br />3. <br />ALL DUCTWORK SPECIFIED SHALL BE CLASSIFIED AS LOW PRESSURE <br />WALL PENETRATIONS SEALED TO SMACNA SEAL <br />CLASS A. <br />AND SHALL BE INSTALLED IN ACCORDANCE WITH 2O15 IMC <br />MAINS <1500 FPM. BRANCHES <br /><1200 <br />REQUIREMENTS AND SMACNA STANDARD FOR 2" WG, UNLESS HIGHER <br />FPM. BRANCH TO DIFFUSER <br /><600 FPM <br />INSULATION PER PER NOTE 2 <br />STATIC PRESSURE ARE INDICATED ON DRAWINGS. <br />TOILET EXHAUST <br />LOW PRESSURE <br />GALVANIZED METAL DUCT <br />FOLLOW BASIC <br />LEVEL <br />A SMACNA CLEANLINESS GUIDELINES. <br />APPROVAL OF <br />1, 2, 3, <br />4 <br />4. <br />ALL DIMENSIONS SHOWN ON PLANS ARE INSIDE CLEAR DIMENSIONS, <br />ATTACHMENTS TO <br />GENERAL EXHAUST <br />SP � 2" WG, EXIT GRILLE <br />TO FAN <br />ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS <br />AND DUCT <br />RELIEVE AIR THROUGH <br />DOORS AND WINDOWS <br />STRUCTURE BY OTHERS <br />5. <br />SUPPLY AND RETURN AIR DUCTWORK OFF THE AIR HANDLING UNIT CAN <br />WALL PENETRATIONS SEALED TO SMACNA SEAL <br />CLASS A. <br />BE UP TO 3" WG STATIC PRESSURE, DEPENDING ON FINAL DUCT <br />VELOCITY <600 FPM <br />ROUTING THROUGH STRUCTURE. DUCT SHALL BE CONSTRUCTED TO <br />INSULATION PER NOTE 2 <br />SMACNA STANDARD TO SUPPORT THAT PRESSURE CLASSIFICATION. <br />[1] <br />DUCT ON THE ROOF SHALL BE INSULATED TO A VALUE OF R-8 IN <br />KEEPING WITH CLIMATE ZONE 4 PER C403.2.6.2 OF THE 2015 WSEC. <br />COPYRIGHT NOTICE <br />THIS LAYOUT/DESIGN IS A <br />COPYRIGHTED WORK OWNED BY <br />COMFORT SYSTEMS USA <br />(NORTHWEST), INC. ("COMFORT <br />SYSTEMS NORTHWEST") AND <br />COMFORT SYSTEMS NORTHWEST <br />HEREBY RESERVES ITS RIGHT TO <br />PREVENT UNAUTHORIZED COPYING, <br />PUBLICATION OR USE OF THIS <br />LAYOUT/DESIGN AND TO OBTAIN <br />DAMAGES THEREFORE. <br />SIGNED: 12/11/2020 <br />VKMIN, <br />1. PERMIT SET 12-11-2020 <br />2. - <br />3. o <br />4. m <br />5. a <br />SHEET NUMBER <br />MOmO4 <br />SHEET 4 OF 22 <br />