Laserfiche WebLink
NEW PANEL 'B" <br />EXISTING PANEL RELABELED "A" ---I <br />ELECTRICAL <br />ROOM <br />107 <br />PRETEST <br />106 <br />BOH <br />105 <br />■1�© <br />RESTROOM <br />104 <br />RP-1 <br />T <br />)23 <br />PHONEBOARD <br />9 <br />m A-12 <br />1 31 <br />LARGE SMALL <br />EXAM EXAM <br />7108 -I--- - -i 109 <br />O.D. <br />RECEPTION <br />111 <br />rD2 <br />GFI <br />A-7 17, A-_FI18 � .- � � � <br />�A-9 23 <br />D19, ,20, 24 <br />22 <br />U <br />E15, <br />44" Wd§ <br />GFI 4 <br />O I ; <br />OFFICE <br />103 <br />A-7 A-9 <br />-'D30 <br />17 18 ---- <br />20 <br />/ 16 <br />A 7 A D23 <br />E07 <br />0 <br />(CLG) <br />17 18 <br />20 <br />UA-9 <br />A- <br />6, B27, <br />9,1330 <br />B 38 <br />" D 11- ' <br />21 <br />Q 17C44 <br />c1 (CLG) <br />CONTACT <br />LENS <br />102 <br />ELECTRICAL - POWER/SYSTEMS <br />SCALE: 1/4" = 1'-T <br />XX KEY NOTES - ELECTRICAL PLAN <br />1. PROVIDE COMMUNICATIONS RACK AT TELEPHONE BOARD. SEE DETAIL ED003. <br />2. PROVIDE ELECTRICAL CONNECTION AND DISCONNECT SWITCH TO NEW WATER HEATER. COORDINATE WITH THE PLUMBING CONTRACTOR PRIOR TO ROUGH -IN, WIRE <br />COMPLETE. <br />3. PROVIDE CEILING MOUNTED SHOW WINDOW RECEPTACLES IN THIS VICINITY. <br />4. E.C. SHALL MAINTAIN FIRE RATING OF DEMISING WALL. IF FIRE RATING CANNOT BE MAINTAINED, ALL POWER AND DATA DEVICES ON THIS WALL SHALL BE SERVED FROM <br />SURFACE MOUNTED RACEWAY. COORDINATE INSTALLATION LOCATIONS WITH EQUIPMENT REQUIREMENTS <br />S. NEW ROOF TOP UNIT RECEPTACLE PROVIDED WITH NEW ROOF TOP UNIT. CIRCUIT AS SHOWN. COORDINATE BRANCH CIRCUIT WIRING PRIOR TO ROUGH IN. <br />6. NEW ROOF TOP UNIT. CIRCUIT AS SHOWN. NEW ROOF TOP UNIT TO BE PLACED IN THE SAME LOCATION AS THE EXISTING ROOF TOP UNIT. <br />7. NOT USED. <br />8. PROVIDE 120V CONNECTION AND TOGGLE TYPE DISCONNECT SWITCH TO SERVE EXTERIOR SIGN. COORDINATE WITH GENERAL CONTRACTOR AND SIGN MANUFACTURER <br />PRIOR TO ROUGH -IN. EXTEND CIRCUIT THROUGH NEW TIME CLOCK, REFER TO ONE -LINE DIAGRAM. COORDINATE TIME CLOCK PROGRAMMING WITH LANDLORD AND <br />TENANT PRIOR TO PROJECT CLOSEOUT. <br />9. INSTALL OWNER FURNISHED AUDIO SYSTEM INCLUDING CABLE, BACK BOXES, SPEAKERS AND VOLUME CONTROL. PROVIDE 3/4" CONDUITS FOR ALL WIRING IF REQUIRED <br />FOR ACCESSIBILITY, LOCAL CODE OR LANDLORD REQUIREMENTS. INCLUDE ALL WORK REQUIRED FOR A COMPLETE SYSTEM IN BID. WHERE A FIRE ALARM SYSTEM IS <br />PRESENT, PROVIDE RELAY TO DISCONNECT POWER TO MUSIC SYSTEM WHEN FIRE ALARM SYSTEM IS IN ALARM. SPEAKERS, WIRING AND ACCESSORIES ARE SUPPLIED AND <br />INSTALLED BY THE SOUND SYSTEM VENDOR. COORDINATE WORK WITH THE VENDOR PRIOR TO CEILING INSTALLATION. SEE DETAIL ED007. <br />10. EC SHALL PROVIDE DATA CABLE FROM TELEPHONE BOARD TO 24" ABOVE CEILING FOR CONNECTION TO SHOPPERTRAK SYSTEM(BY OTHERS). PROVIDE MINIMUM 6 FT <br />COILED CABLE AT BOTH ENDS. <br />11. EC SHALL PROVIDE A-CAT6 DATA CABLE FROM TELEPHONE BOARD TO 24" ABOVE CEILING FOR CONNECTION TO WIRELESS ACCESS POINT. COORDINATE EXACT LOCATION <br />WITH PROJECT MANAGER PRIOR INSTALLATION. <br />12. DOOR STROBE/BELL SYSTEM IS COMPRISED OF (3) COMPONENTS. (1) SERVICE DOOR PUSH-BUTTON, (1) STROBE/BELL LOCATED ABOVE GENERAL MANAGER'S (GM) DESK AT <br />AN ELEVATION OF 8'-0", AND (1) TRANSFORMER LOCATED NEXT TO STROBE/BELL SEE DETAIL E006. <br />13. PROVIDE CORE DRILLING OR TRENCHING (AS APPLICABLE) FOR POWER AND TELE/DATA. E.C. SHALL VERIFY ALL CORE DRILLING REQUIREMENTS WITH THE LANDLORD PRIOR <br />TO THE START OF WORK. PROVIDE DEVICES AND DEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTION REQUIREMENTS <br />WITH FURNITURE MANUFACTURER REPRESENTATIVE. <br />14. FINISH OF FLOOR BOXES SHALL BE BRUSHED ALUMINUM. COORDINATE WITH THE G.C. PRIOR TO PURCHASING. <br />15. CONTROL CIRCUIT THROUGH LIGHTING SWITCH BANK. SEE DETAIL ED033. <br />16. INSTALL LEVITON LOW PROFILE RECESSED ENTERTAINMENT BOX AT LOCATION INDICATED ON ARCHITECTURAL ELEVATION FOR SUPPLY TO DIGITAL EYE CHART. EXACT <br />DIMENSION IS CRITICAL. PROVIDE THE DEVICES INDICATED . PROVIDE ALSO A 1 1/2" CONDUIT FROM BOX TO JUNCTION BOX UNDER THE EXAM DESK. SEE DETAIL E114 <br />17. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM. PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY <br />SYSTEM TO ENSURE THAT THE RACEWAY SYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE CONDUCTOR AND THE <br />RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED. <br />18. ALL RECEPTACLES IN THE BACK OF HOUSE AND ACCESSIBLE TO THE PUBLIC ARE TO BE TAMPER RESISTANT. <br />19. PROVIDE "RECESSED" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL ED008, <br />20, SEE ELECTRICAL DIMENSION SHEET FOR EXACT PLACEMENT OF ELECTRICAL DEVICES. <br />21. PROVIDE WIRING FOR TENANT INSTALLED SURVEILLANCE EQUIPMENT. SEE DETAIL ED005. <br />22. CONVENIENCE RECEPTACLE FINISH TO MATCH ADJACENT WALL FINISH AS CLOSE AS POSSIBLE. SALES FLOOR RECEPTACLES ARE TO USE THE LEVITON REND SYSTEM. VERIFY <br />COLOR WITH NEXTORE PROJECT MANAGER FROM STANDARD PALETTE. <br />23. PROVIDE DEVICE RING AND CLOCK STYLE OUTLET FOR MONITOR. <br />24. ROUTE PLENUM RATED HDMI CABLE FROM BOX TO BOX, OVER CEILING AND IN WALL. PROVIDE IN CONDUIT WHERE REQUIRED BY THE JURISDICTION. <br />25. PROVIDE DEVICE RING FOR HDMI CABLE. <br />26, PROVIDE JUNCTION BOX AND DISCONNECT SWITCH FOR INTERIOR ILLUMINATED SIGNAGE SWITCH SHALL SHUT-OFF SIGNAGE CIRCUIT. LABEL SWITCH FOR WHAT IT <br />SERVES. DISCONNECT SWITCHES SHALL BE LOCATED ABOVE CEILING IN AN ACCESSIBLE AREA IN THE BACK OF THE STORE OR AT AN ACCESS PANEL LOCATION AND <br />GROUPED TOGETHER. <br />27. CUSTOM CEILING SUPPLIED FREE STANDING FIXTURE. PROVIDE BOARD ABOVE CEILING AND ACCESS PANEL TO ELECTRICAL DEVICE MOUNTING. <br />28. MECHANICAL CONTRACTOR SHALL PROVIDE ADDRESSABLE DUCT MOUNTED SMOKE DETECTOR. MECHANICAL CONTRACTOR SHALL INSTALL SMOKE DETECTOR IN THE <br />RETURN AIR DUCT. ELECTRICAL CONTRACTOR SHALL PROVIDE WIRING TO FAN INTERLOCK, E.C. SHALL MAKE FINAL CONNECTIONS TO THE REMOTE ANNUNCIATORS. E.C. <br />SHALL COORDINATE EXACT PRODUCTS/DEVICES WITH LANDLORD AND COORDINATE WITH LANDLORD AND FIRE ALARM CONTRACTOR FOR INSTALLATION, TESTING AND <br />PROGRAMMING. CONTRACTORS MAY RETAIN DUCT DETECTORS FOR EXISTING UNITS AS APPLICABLE. WHEN THERE IS NO FIRE ALARM SYSTEM, DETECTORS TO OPERATE IN <br />STANDALONE FUNCTION; PANEL TO BE PROVIDED BY THE EC AND INCLUDE A DIALER. <br />29. TIE EXHAUST FAN INTO LOCAL LIGHTING CIRCUIT; TO BE CONTROLLED WITH LOCAL LIGHTING SWITCH. <br />30. PROVIDE POWER AND COMMUNICATIONS CONDUITS IN WALL TO SERVE RECEPTION DESK. DATA CONDUIT TO BE 2", POWER CONDUIT TO BE A 1". ROUTE CONDUIT WITHIN <br />MILLWORK FROM WALL TO DEVICES AS APPLICABLE. <br />31. TELEPHONE TERMINAL BOARD: 4'X8'X3/4" FIRE RATED PLYWOOD. PROVIDE PHONE BOARD FOR RETAIL SALES SIDE OF SPACE AND DOCTORS/REFRACTION SIDE OF SPACE. <br />B-23 <br />15 <br />B I� 01Ml <br />C01 CO3 <br />II � <br />O <br />::y <br />I I I <br />I I I <br />H- <br />I <br />s I I I <br />B- 1 <br />15 <br />II <br />I I <br />27 <br />I <br />I I I <br />I <br />II <br />I <br />II <br />CAL <br />OI 3 <br />3 2 I I I <br />II I <br />II I <br />II I <br />II 1 <br />RETAIL SALES <br />101 <br />STOREFRONT <br />100 <br />GENERAL NOTES - ELECTRICAL <br />A. ALL MATERIAL SPECIFICATIONS ARE LOCATED ON THE "SPECIFICATION SCHEDULE" <br />B. ALL TELEPHONE CABLING/DATA CABLING TO BE RUN IN CONDUIT TO 6" ABOVE CEILING. PROVIDE 6' OF <br />EXTRA CABLING AT ALL TELEPHONE/DATA TERMINATIONS. ALL CABLING SHALL BE PLENUM RATED. RUN <br />PHONE/DATA CABLING COMPLETELY IN CONDUIT IF LOCAL CODES/MUNICIPALITIES REQUIRE IT (FIELD <br />VERIFY). ALL CABLING SHALL BE ROUTED AWAY FROM ALL ELECTRIC EQUIPMENT (WITH -IN 18") AND <br />SECURED TO STRUCTURE ABOVE. <br />C. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE AS <br />FOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48% ELECTRICAL/TELEPHONE/DATA <br />OUTLETS-18% THERMOSTATS-5'-0", TOP OF PANELBOARDS 6-6", TIMECLOCKS-5'-0". FOR ALL LENS <br />PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRING SCHEDULE. <br />D. ALL ROOF PENETRATIONS TO BE COORDINATED WITH THE LANDLORD'S DESIGNATED ROOFING <br />CONTRACTOR. <br />E. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIOR LIGHTING <br />FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE <br />F. CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE, <br />G. CONDUIT SHALL BE 6-0". <br />H. CONDUIT AND OUTLETS FOR SECURITY, DATA, TELEPHONE AND ELECTRIC MAY REQUIRE REMOVAL OF <br />CONCRETE SLAB OR ROUTING OF CONDUIT DISCONNECT SWITCHES SHALL BE GENERAL DUTY IN UNDER <br />FLOOR IN SPACE BELOW. <br />I. DISCONNECT SWITCHES SHALL BE GENERAL DUTY IN APPROPRIATE NEMA ENCLOSURES. A LINE <br />VOLTAGE, HORSEPOWER RATED DISCONNECT SWITCH SHALL BE INSTALLED ADJACENT TO EACH <br />MOTOR. <br />J. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF, <br />K. REFER TO THE MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT AND REQUIRED <br />ELECTRICAL CONNECTIONS. <br />L. ALL TEMPORARY WIRING SHALL BE REMOVED WHEN PERMANENT POWER IS AVAILABLE. <br />M. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILL BE <br />RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS AND SUBMITTING <br />SAME TO NEXTORE AND THE LANDLORD. <br />N. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF <br />THE SYSTEM (WITH -IN 10%): <br />O. SEE ARCHITECTURAL ELEVATIONS FOR ADDITIONAL INFORMATION ON PLACEMENT OF OUTLETS & <br />SWITCHES. <br />P. FOR ALL MILLWORK ELECTRIC, DATA, AND TELEPHONE OUTLETS, REFER TO THE DETAILS IN THIS SET. <br />Q. ALL DATA/PHONE CABLING MUST BE PROPERLY IDENTIFIED W/ NUMBER AND/OR COLOR SYSTEM AT <br />BOTH ENDS. <br />R. ANY PENETRATIONS THROUGH FIRE-RESISTANT/RATED WALLS, PARTITIONS, FLOORS, AND CEILINGS <br />SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. <br />S. RECEPTACLE CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE#12 CONDUCTORS MINIMUM. <br />RECEPTACLE CIRCUITS FROM 10T-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. <br />RECEPTACLE CIRCUITS FROM 15T-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. <br />RECEPTACLE CIRCUITS ABOVE 250'-0" IN LENGTH SHALL UTILIZE #6 CONDUCTORS MINIMUM. <br />T. E.C. SHALL PROVIDE JUNCTION BOX AND RACEWAY FOR THERMOSTATS, THERMOSTATS AND <br />TEMPERATURE SENSORS INSTALLED AND WIRED BY MECHANICAL CONTRACTOR. COORDINATE EXACT <br />LOCATIONS AND MOUNTING HEIGHTS WITH MECHANICAL CONTRACTOR. TYPICAL OF ALL. <br />U. DUCTWORK AND PIPING SHALL NOT BE ROUTED OVER ELECTRIC PANELS OR TRANSFORMERS. <br />V. IT IS THE RESPONSIBILITY OF THE E.C. TO REVIEW ALL ARCHITECTURAL DRAWINGS, ELECTRICAL <br />DRAWINGS AND NOTES TO INSURE THAT ALL ELECTRICAL REQUIREMENTS ARE MET. <br />W. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES <br />AND ORDINANCES. CONTRACTOR SHALL ENSURE THE INSTALLATION OF HOSPITAL GRADE MC CABLE <br />COMPLIANT WITH NEC 517 IN JURISDICTIONS WHERE REQUIRED. <br />X. IF APPLICABLE, ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND <br />CIRCUIT NUMBER. <br />Y. REFER TO SHEET E202 FOR TELEPHONE AND DATA OUTLET LOCATIONS. <br />Z. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK <br />PRIOR TO CONNECTION. <br />COORDINATION NOTES <br />C01. DO NOT ROUGH IN ANY RECEPTACLES OR DATA OUTLETS ON THE SALES FLOOR WITHOUT FIRST CONFIRMING EXACT <br />LOCATION WITH NEXTORE PROJECT MANAGER. <br />CO2. DO NOT PURCHASE FLOOR BOXES WITHOUT FIRST VERIFYING FINISH (FROM MANUFACTURER'S STANDARD) FOR A <br />PARTICULAR BOX IN A PARTICULAR LOCATION. <br />CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR <br />SHALL REVISE CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA <br />AS WELL AS CIRCUITS THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. <br />NOTE <br />CIRCUITS WERE TAKEN FROM PICTURES OF THE ELECTRICAL PANEL DIRECTORY CARDS. ELECTRICAL CONTRACTOR SHALL REVISE <br />CIRCUITS SHOWN ON THESE PLANS TO WORK WITH EXISTING CIRCUITS THAT MAY EXIST IN THE AREA AS WELL AS CIRCUITS <br />THAT ARE TO REMAIN POWERING EXISTING EQUIPMENT. <br />INFORMATION IS BASED ON SURVEY <br />PICTURES. VERIFY ALL WORK IN FIELD. <br />ADVISE NEXTORE PROJECT MANAGER OF <br />ANY DISCREPANCIES. <br />DO NOT INSTALL JUNCTION BOXES (WITH OR WITHOUT COVERS) VISIBLE <br />TO THE PUBLIC IN THE SALES AND PUBLIC BACK OF HOUSE AREAS. IF <br />THIS IS DONE, THE GC IS REQUIRED TO REMOVE THE JUNCTION BOX AT <br />HIS/HER EXPENSE. <br />00` SPECIAL POWER CONNECTIONS SCHEDULE <br />TAG <br />DESCRIPTION <br />POWER <br />HP <br />POWER <br />WATTS <br />MAX <br />FUSE <br />MCA <br />FLA <br />VOLTIPH <br />DISC. <br />CIRCUIT <br />FEEDER <br />NOTES <br />RTU-1 <br />ROOFTOP UNIT <br />0.75 <br />30 <br />21 <br />208/3 <br />FSSW <br />A-31,33,35 <br />(4)#6, (1)#10G <br />RTU-2 <br />ROOFTOP UNIT <br />2.75 <br />50 <br />42 <br />209/3 <br />FSSW <br />A-37,39,41 <br />(4)#8, (1)#10G <br />CEF-1 <br />EXHAUST FAN <br />12OW <br />20 <br />120/1 <br />NFSSW <br />A-28 <br />(2)#12, (1)#12G <br />1 <br />RP-1 <br />RICIRCULATION PUMP <br />100W <br />20 <br />120/1 <br />NFSSW <br />A-25 <br />(2)#12, (1)#12G <br />WH-1 <br />WATER HEATER <br />6000W <br />40 <br />208/1 <br />NFSSW <br />A-21,23 <br />(3)#8, (1)#10G <br />NOTES: <br />1. EXHAUST FAN TO BE CONTROLLER THROUGH LOCAL LIGHTING CIRCUIT, <br />is <br />STORE 06261 <br />EVERETT MALL - 910 CENTER <br />910 SE EVERETT MALL WAY <br />EVERETT, <br />WA 98208 <br />Construction for: <br />z <br />® <br />o <br />�o <br />O �q <br />® <br />00 <br />® <br />�O <br />I <br />Oqf <br />x O <br />b <br />o <br />4 <br />O <br />I LU <br />� m <br />g <br />o <br />N <br />�o <br />LU <br />40am <br />Revisions: <br />Mark Date <br />0 <br />0 <br />0 <br />A <br />A <br />Thorson Baker <br />Associates <br />C O N S U L T I N G <br />E N G I N E E R S <br />3030 West Streetsboro Road <br />Richfield, Ohio 44286 <br />(330) 659-6688 Phone <br />(330) 659-6675 Fax <br />Seal <br />315861 , <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />7 <br />Nextore Project <br />Number 86841 <br />Brand Design Type: <br />SKIN <br />ISSUED FOR: <br />CONSTRUCTION <br />Title <br />POWER/SYSTEMS <br />PLAN <br />Date <br />04/19/2022 <br />Drawn By <br />TBA <br />Sheet <br />E21 <br />Checked By <br />