rgy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised <br />Project Address 3901 HOYT AVE <br />Date 9/3/2014 <br />Lighting Alterations, Renovations & Building Additions <br />For Building Department Use <br />Less than 60% O 60% or more o Stand alone o Addition <br />fixtures replaced fixtures bldg. addition combined <br />Notes: <br />a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be <br />combined with the overall existing bldg lighting to demonstrate compliance. Refer to <br />C 101.4.3. <br />b. For retrofits and building additions, provide Space Types and gross interior areas in the <br />Maximum Allowed Lighting table. If a builidng addition will comply as combined with the <br />overall <br />existing builidng, include all applicable existing Space Types and gross interior areas. <br />c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br />ndn 0 <br />MalvigLtuaf'o[�l�dlµr c pghtip►g iW&tt4ggri Allowed Lighting table. <br />Location (plan #, <br />room #) <br />Space Type' <br />Watts per ft2 <br />Area in ft(watts/ft2 <br />x area) <br />SE111, SW140, <br />Office -Open plan <br />0.98 <br />766 <br />SW144 <br />NE101 <br />Office - Enclosed <br />1. 11 <br />77 <br />SE110 <br />Electrical/mechanical <br />0.95 <br />68 <br />SW102, SW104, <br />Health care clinic/hospital: Corridors/transition <br />0.89 <br />254 <br />NE100 NW129 <br />SW155 <br />Restroom <br />0.98 <br />55 <br />NW126.1 <br />Health care clinic/hospital: Examltreatment <br />1.66 <br />51 <br />num Enter <br />xis rng Lighting Enter hxlsL 1721 <br />1721 <br />etai?Display Allowance from LTG4NT-DISPLAY <br />Select Table C405.5.2(2) category from drop down menu. <br />" For atriums, indicate height. Allowed wettage for first 40 feet is 0.03 Wift. ht., <br />above 40 feet is 0.02 WlR. ht. <br />Proposed Lighting Wattage <br />Area Allowed Watts <br />Total 1271 —�1721 <br />Location (plan #, <br />room #) <br />Fixture Description— <br />Number of <br />Fixtures <br />Watts/ <br />Fixture <br />Watts <br />Proposed <br />L-2 2X4 LAY -IN, 2 LAMP <br />3 <br />64 <br />192 <br />L-3 PENDANT <br />8 <br />40 <br />320 <br />L-8 2X4 LAY -IN, DIRECT/INDIRECT, 2 LAMP <br />2 <br />64 <br />128 <br />L-19, EXIT LIGHT, EXEMPT <br />L-48 RECESSED DIMMABLE LED DOWNLIGHT <br />16 <br />15 <br />240 <br />L-49 WALL MTD. LINEAR FLUORESCENT, 2 LAMP <br />8 <br />64 <br />512 <br />L-50 WALL MTD., LINEAR, LENSED, LED <br />2 <br />50 <br />99 <br />L-22 VANITY FIXTURE, 2 LAMP <br />1 <br />34 <br />34 <br />Retail Display_ Lighting from LTGINT-DISPLAY <br />Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Waft 1525 <br />Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br />Notes: <br />1. Include ALL proposed lighting fixtures. <br />2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). <br />For <br />track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. <br />3. For proposed Watt&Fixture, use manufacturer's fisted maximum input wattage of the fixture (not simply the lamp wattage) and other <br />criteria <br />as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by <br />50, <br />or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. <br />�pyrppprp�e�lp�j�trrgllj�dLlrghting table in the same manneras new fixtures. Identify as existing CUES <br />ow <br />