My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE JOINT CHIROPRACTIC 2023-02-06
>
Address Records
>
19TH AVE SE
>
12906
>
JOINT CHIROPRACTIC
>
12906 19TH AVE SE JOINT CHIROPRACTIC 2023-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2023 2:35:07 PM
Creation date
2/6/2023 2:34:32 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Tenant Name
JOINT CHIROPRACTIC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ig ting, Y otor an• ectrica -equirements ist, pg 5 o 11 <br /> 2018'WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> { E i <br /> For building facade and landscape lighting, 1 I <br /> indicate control sequence for shut-off control <br /> is based on dawn-to-dusk and business <br /> J 1 opening/closing schedule;indicate whether <br /> automatic of time switch controls will be ! 4 <br /> I i i provided for this function <br /> C405.5.2 Lighting control of Indicate that exempt exterior lighting and <br /> exempt exterior I lighting located^within exterior areas/surfaces <br /> lighting that eligible for a lighting power exemption <br /> are controlled independently from non- <br /> exempt <br /> exterior lighting <br /> • <br /> —� -- <br /> C405.5 s Exterior gas fired Indicate ignition system is a method other ( ^ ' <br /> i )lighting appliances i then continuously burning pilot light <br /> NO C405.2.7 Area controls- Indicate location(s)of master control general switching <br /> Master control switch(es)intended to control multiple shown-final switching <br /> switches and circuit independent switches;circuit breaker may not by electrical <br /> power limit be used as a master control switch contractor under their <br /> • permit <br /> NO Verify that no 20 amp circuit controlled by a general switching <br /> • single switch or automatic control is loaded shown-final switching <br /> beyond 80% by electrical <br /> contractor under their <br /> permit <br /> ADDITIONAL EFFICIENCY CREDIT-ENHANCED INTERIOR LIGHTING CONTROLS <br /> C406.4 Enhanced digital I To comply with additional efficiency credit, <br /> lighting controls indicate on plans that interior lighting fixtures I j <br /> are configured with all of the following <br /> I control functions,as applicable: 1)Each <br /> fixture is individually addressed,or exception I I <br /> taken:2)Fixtures are configured for , <br /> continuous dimming;3)No more than eight <br /> fixtures are controlled by a single daylight <br /> sensor;4)in enclosed and open office areas, <br /> illumination levels of overhead general area <br /> lighting is configured to be individually <br /> adjusted by occupants <br /> -- j Include calculations that demonstrate the total <br /> I j lighting power of all interior lighting fixtures <br /> configured with enhanced lighting controls is <br /> no less than 90%of the total interior lighting <br /> I i power for the area the enhanced lighting <br /> controls credit is being applied to <br /> INTERIOR LIGHTING POWER&EFFICACY <br /> YES C405.4.1 Total connected Include all luminaires in interior lighting see WSEC form in <br /> C405.4.2 interior lighting fixture schedule;indicate fixture types,lamps, pemrit package <br /> power ballasts,and manufacturer's watts per fixture <br /> for the installed lamp <br /> NO Identify spaces eligible for lighting power didn't apply <br /> exemption on plans and in WSEC interior exemptions <br /> lighting compliance reports;indicate the <br /> exception applied <br /> � 1 <br /> • <br /> Page 5/11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.