My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12906 19TH AVE SE JOINT CHIROPRACTIC 2023-02-06
>
Address Records
>
19TH AVE SE
>
12906
>
JOINT CHIROPRACTIC
>
12906 19TH AVE SE JOINT CHIROPRACTIC 2023-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2023 2:35:07 PM
Creation date
2/6/2023 2:34:32 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12906
Tenant Name
JOINT CHIROPRACTIC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at cam.techsupport@waenergycodes.com <br /> NO I Provide schedule that lists the number of { general switching { j <br /> controlled and uncontrolled receptacles in 'shown-final switching <br /> each space where controlled receptacles are by electrical { <br /> { required-classrooms,private offices,open contractor under their <br /> office areas,conference rooms,copy rooms, {permit <br /> break rooms and modular <br /> (partitions/workstations ( I <br /> NA Indicate on plans the method of automatic <br /> control for each controlled receptacle zone <br /> { (occupant sensor or programmable time-of- <br /> day <br /> control);indicate that each zone served by <br /> a single controller does not exceed 5,000 sf• <br /> • <br /> C405.2.5, Switched receptacles Indicate method of automatic off control of <br /> hem 2 in sleeping units all switched receptacles in sleeping units <br /> (vacancy or key card control) <br /> NA C503.6.6 —I Electrical receptacle i Where new receptacles are added or replaced <br /> alerations I within an alteration project that is 5,000 sf or <br /> larger,indicate receptacles are provided with <br /> automatic controls per C405.10,or exception <br /> taken <br /> MOTORS,TRANSFORMERS,ELECTRIC METERS,INTERIOR TRANSPORTATION <br /> • <br /> C405.6 E Electrical Include electrical transformer schedule on ? i <br /> (transformers electrical plans:indicate transformer type_ <br /> i a <br /> size,efficiency,or exception taken I I <br /> ' 3 <br /> NO C405.11 Feeders and branch Provide documentation that demonstrates general switching <br /> { circuits maximum voltage drop across feeders and shown-final switching <br /> branch circuits does not exceed 5% by electrical <br /> contractor under their <br /> permit I j <br /> C405.7 Dwelling unit °Indicate on electrical plans that each dwelling <br /> electrical energy unit in Group R-2 has a separate electrical <br /> consumption ; energy meter <br /> C405.8 Electric motor Include all motors.including fractional hp I j <br /> efficiency (motors,in electric motor schedule on <br /> electrical plans;indicate motor type, <br /> horsepower,rpm,rated efficiency,or <br /> exception applied <br /> C405.9.1 Elevator cabs (For luminaires in each elevator cab,provide <br /> calculations that demonstrate average efficacy <br /> is not less than 35 lumens per.watt <br /> For elevators that do not have an integral air <br /> ( conditioning system,indicate rated watts per <br /> cfrn for elevator cab ventilation fans do not <br /> exceed 0.33 waits per cfm <br /> • <br /> I ( Indicate automatic controls that de-energize <br /> 1 <br /> { ! lighting and ventilation fans when elevator is <br /> stopped and unoccupied for a period of 15 <br /> ii Minutes or more. . { <br /> — — C405.9.2 Escalators and (Indicate escalators comply with ASME <br /> 1 — <br /> moving walks a17.1/CSA S 44:automatic controls are <br /> configured to reduce operational speed to the <br /> — ,minimum permitted when not in use ! <br /> Page 9/11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.