Laserfiche WebLink
C <br />a <br />7 1 1 711 <br />1,7G I5Q/fT <br />(TYPE '13" UNIT OPTION B BATHROOM <br />1 004 <br />VENTILATIO <br />SUBMIT FOR BUILDING PERMIT - 24 MAY 18 <br />05 OCT 18 - REVISED PER CITY REVIEW LETTER <br />24'-43" <br />C <br />C\ <br />(TYPE "b" UNIT) <br />��01 �Q/I9T <br />3 UNIT <br />DECK/PATIO - 40 5Q/PT <br />UNIT5 # 108, 208 308 <br />1,803 SQ/ET <br />(TYPE "B UNIT OPTION B BATH KOOM <br />PEK AN5I 1 17.1-2009 5EC. 1004.1 I .3.2) <br />24'-1 loll <br />(TYPE 13" UNIT) <br />59 SQ/I=T <br />3 UNITS <br />DECK/PATIO - 40 5Q/ET <br />UNIT5 # I OG, 20G 30G <br />1,766 Q/ET <br />DUNIT OPTION B BATHROOM <br />SHEET NOTES <br />SELF -RIMING STAINLESS STEEL SINK; SINGLE BOWL; SINGLE LEVER <br />❑) <br />FAUCET. ENSURE KNEE CLEARANCE AT 27" AFF IN TYPE "A" UNITS <br />PROVIDE BACKING FOR GRAB BARS IN ALL BATHROOM UNITS AS SHOWN ON SHEET AG. I � AG.2. <br />ALL TOILETS SHALL BE CENTERED EXACTLY 18 INCHES FROM FACE OF FINISHED 51DE WALL. <br />® <br />BUILT-IN DISHWASHER, ENERGY STAR <br />® <br />30" ELECTRIC RANGE WITH MICROWAVE/HOOD FAN ABOVE <br />PROVIDE ACCESSIBLE CONTROLS FOR POWER AND SPEED AT WALL MOUNTED CONTROLS. <br />ENSURE THAT CONTROLS ARE NOT LOWER THAN 15" AND AT TYPE "A" UNITS THAT THE CONTROLS DO NOT <br />® <br />30" ELECTRIC RANGE WITH HOOD FAN ABOVE <br />REQUIRE TWISTING OR GRIPPING. <br />REFRIGERATOR SPACE <br />BALCONIES FOR TYPE "A" UNITS MUST HAVE GO" CLEAR FOR A TURNING SPACE. <br />[�] <br />PLASTIC LAMINATE COUNTERTOP WITH 4" WATERFALL BACK5PLA5H <br />AND BULLFRONT EDGE; CABINETS BELOW <br />OPERABLE WINDOWS MUST BE ACCESSIBLE WITH ACCESSIBLE CONTROLS WITHIN REACH RANGE. <br />LINE OF CAABINBIN ETS ABOVE <br />FOR TYPE "A" UNITS ALL CONTROLS MUST BE ACCESSIBLE (LEVER STYLE OR SIMILAR) WHICH INCLUDES OPERABLE <br />® <br />PONY WALL <br />WINDOWS, SINK AND LAVATORY FAUCETS, KITCHEN CABINET DOOR HARDWARE; AND DOOR HARDWARE. <br />METAL CARPET STRIP @ CARPET/VINYL TRANSITION <br />FOR TYPE "A" UNITS AND A PORTION OF ALL STORAGE CLOSETS MUST BE ACCESSIBLE, ENSURE THAT A PORTION <br />OF A CLOSET POLE IS MOUNTED NO GREATER THAN 4G INCHES AFF. <br />I 0 <br />30X24 WORK AREA @ MAX 34" HEIGH I - OPEN BELOW <br />FOR TYPE "A" UNIT PROVIDE A SINK WITH A DRAIN AT THE BACK OF THE BOWL 50 THAT DRAIN PIPES AND <br />I I <br />1.28 GAL. MAXIMUM FLUSH WATER CLOSET; ROUND BOWL; PROVIDE IN SPACE <br />MINIMUM 30 WIDE IN ACCESSIBLE UNITS, MINIMUM 33" WIDE IN ADAPTABLE UNITS <br />DISPOSAL UNITS ARE OUT OF THE KNEE CLEARANCE SPACE. <br />2 <br />GRAB BARS FOR WATER CLOSET <br />PROVIDE COUNTER TOP MICROWAVE FOR TYPE "A" UNITS <br />F173 <br />RECESSED TOILET PAPER DISPENSER, MOUNT BOTTOM MIN 1 5" AFF * TOP MAX 33" AFF <br />FOR ALL UNITS PROVIDE A PORTION OF TOWEL BARS MOUNT AI 46" AFF. <br />I Z- <br />PORCELAIN OVER STEEL LAVATORY; SINGLE LEVER 1.5 GPM FAUCET AND CABINET <br />FOR TYPE "A" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 3G" FROM INSIDE CORNED OF WALL SURFACE IN "L" <br />15 <br />SURFACE MOUNTED MIRROR WITH J-CLIPS TO MATCH VANITY <br />AND U SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 24" THE ACCE551BLE OUTLET IN THE CORNER <br />I G <br />30" TOWEL BAR; PROVIDE SOLID BACKING IN WALL; MOUNT CENTER OF BAR <br />15 CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2". WHERE TWO OR MORE RECEPTACLE OUTLETS ARE <br />MAX. 4'-G" AFF. IN ALL UNITS MOUNT A PORTION OF TOWEL BARS @ 48" AFF <br />PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT 15 UNINTERRUPTED BY A SINK OR APPLIANCE, <br />I <br />FIBERGLASS TUB WITH PLASTIC LAMINATE SURROUND: TOP OF SURROUND <br />ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/ANSI A 1 1 7. 1-2009 SECTION 309. <br />MINIMUM 72" ABOVE FLOOR; PROVIDE WITH BATH CURTAIN ROD <br />"L" <br />I <br />SHOWER HEAD 1.75 GPM ; MOUNT 4" ABOVE TOP OF SURROUND <br />FOR TYPE "B" UNITS THE KITCHEN CORNER OUTLETS MINIMUM 3G" FROM INSIDE CORNER OF WALL SURFACE IN <br />AND "U" SHAPED KITCHENS. WHERE RANGE PROJECTS MORE THAN 25 1 /2" THE ACCE55113LE OUTLET IN THE <br />I <br />PURR WALL TO TUB ENCLOSURE; VERIFY DIMEN51ON5 <br />CORNER IS CALCULATED BY APPLIANCE DEPTH DIMENSION PLUS 1 2". WHERE TWO OR MORE RECEPTACLE <br />OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTERTOP THAT 15 UNINTERRUPTED BY A SINK OR <br />20 <br />5SHOWER <br />APPLIANCE, ONE RECEPTACLE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH ICC/ANSI A 1 1 7. 1-2009 <br />SECTION 309. <br />2 I <br />SHOWER SEAT <br />22 <br />SHOWER SPRAY UNIT 1.75 GPM, WITH A HOSE AT LEAST GO" LONG, THAT CAN BE USED <br />FOR TYPE "A" UNIT PROVIDE COMBINATION WASHER/DRYER. PROVIDE FOR PARALLEL APPROACH. CLEAR FLOOR <br />AS A FIXED5HOWER HEAD OR AS A HAND HELD SHOWER <br />SPACE SHALL BE CENTERED ON APPLIANCE. <br />23 <br />GRAB BARS FOR TUB OR ROLL -IN SHOWER <br />OPERABLE PARTS INCLUDING DOORS, LINT SCREEN, DETERGENT AND BLEACH <br />1241 <br />STACKED WA5HER/DRYER W/ VENT TO THE EXTERIOR (80 CFM), ENERGY STAR <br />COMPARTMENTS SHALL BE NO LOWER THAN 15" ABOVE F.F. AND NOT MORE THAN 401 <br />25 <br />ABOVE F.F. <br />COMBINATION WA5HER/DRYER W/ VENT TO EXTERIOR (80 CFM), ENERGY STAR <br />TYPE "A" KITCHEN COUNTERTOP 24" MAX. DEPTH, 34" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER IS <br />12IS <br />I - 1 2" SHELF �- POLE (PREFI1\1I5HED) <br />HIGHEST). <br />27 <br />5 - 1 2" SHELVES (PREFINI5HED) <br />TYPE "B" KITCHEN COUNTERTOP 25 1/2" MAX. DEPTH, 3G" MAX. HEIGHT (TOP OF SINK OR COUNTER WHICHEVER <br />IS HIGHEST). <br />2(75 <br />4' 5HOWER <br />IYPE A 1511 BATHROOM COUNTERTOP 24 MAX. DEPTH, 34 MAX. HEIGHT (TOP OF SINK OR COUNTER <br />WHICHEVER 15 HIGHEST). <br />29 <br />ADA 3' TRANSFER TYPE SHOWER WITH SEAT <br />FOR TYPE "B" UNITS A 5TACKABLE WA5HER/DRYER COMBINATION CAN BE PROVIDED. <br />30 <br />ADA 5' ROLL -IN SHOWER WITH SEAT <br />royAlw lY <br />all <br />(TYPE "B" UNIT) <br />593 /ET <br />3 UNITS <br />DECK/PATIO - 40 5Q/ET <br />UNIT-9 # 105, 205 305 <br />1,779 Q/ET <br />_ OPTION 1313ATHKOOM <br />_P ' - 00#f <br />ARCHITECT TO REVIEW BATHING FIXTURE 5UBM11 I AL <br />PRIOR TO FRAMING TO CONFIRM COMPLIANCE. <br />SEE SHEET AG. I INTERIOR ELEVATIONS FOR LOCATION <br />OF GRAB BARS AND BACKING. ALSO NOTE LOCAI ION <br />OF WATER CLOSETS AND TUB CONTROLS <br />NOTE: ALL DOORS TO BE 3'-O"X G'-8" <br />UNIT ENTRY DOORS TO BE 20 MIN RATED <br />AND BE EQUIPPED WITH VIEWER � DEAD BOLT LOCK <br />ALL HARDWARE TO HAVE LEVER LOCK5ET5 <br />PUBLIC SITE OF THE UNIT PRIMARY ENTRANCE PER ANSI SECTION 1005.5. 1 <br />A MEANS FOR VISUALLY IDENTIFYING A VISITOR WITHOUT OPENING THE UNIT <br />ENTRY DOOR SHALL BE PROVIDED PER ANSI SECTION 1005.5.2 <br />NOTE: ALL BATHS * KITCHENS TO BE MECHANICALLY VENTED TO EXTERIOR <br />NOTE: PROVIDE REMOVABLE CABINET IN ALL BATHROOM AND SUPPORT AT OPEN END. <br />PROVIDE FINISH FLOOR UNDER REMOVABLE CABINET <br />ALL UNITS NOT DESIGNATED AS TYPE "A" SHALL BE TYPE "B' UNITS <br />ALL TYPE "A" UNITS SHALL MEET THE REQUIREMENTS OF ICC/ANSI A 1 1 7. 1-2009 <br />OUTLETS TO BE NO LOWER THAN 15" HIGH MEASURED FROM CENTERLINE OF LOWEST <br />OU LET TO THE FINISH FLOOR. <br />COUNTER TOP OUTLETS TO BE MAXIMUM 44" HIGH MEASURED FROM FINISHED FLOOR TO <br />HIGHEST OUTLET. <br />SWITCHES AND THERMOSTATS MAXIMUM 46" TO THE HIGHEST CONTROLS. <br />KITCHEN CORNER OUTLETS MUST BE A MINIMUM 3G FROM INSIDE CORNER OF WALL <br />SURFACE IN L-SHAPE AND U-SHAPE KITCHENS. <br />NOTE: ALL WINDOWS TO BE DOUBLE GLAZED VINYL FRAME W/ACCESSIBLE CONTROLS <br />WINDOWS W/.28 "U" FACTOR * .40 5HGC <br />L E <br />VERI FY WALL TYPES AS PEP RA 1 1 SH EE I <br />STANDARD WALL ( I H R)(SEE SHT RA 1. 1 #3) ® WINDOW INDICATOR <br />CORRIDOR WALL (SEE SHT RA 1. 1 #4) DOOR INDICATOR <br />PLUMBING CORRIDOR WALL (SEE SHT RA 1. I #4) SOFFITS FOR DUCTS <br />UNIT PARTITION WALL (SEE SHT RA 1. 1 #5) DETAIL INDICATOR (SEE D 1. SHTS) <br />EXTERIOR WALL (SEE SHT RA 1. 1 # 1) <br />2 HR WALL - GENERIC (SEE SHT RA I. I #G) 6 INTERIOR ELEVATIONS (SEE SHT AG. 1) <br />8 <br />2 HR WALL - (STC 50) (SEE SHT RA 1 .2 #20) <br />2 HR EXTERIOR WALL (SEE SHT RA 1 .2 # 1 9) SA SMOKE DETECTORS <br />AREA SEPARATION FIRE WALL - (SEE SHT RA 1. 1' -#7) OO CARBON MONOXIDE DETECTOR <br />EXTERIOR WALL - FIRE BOTH SIDES (SEE SHT RA 1. 1 #2) <br />C"HARLES" MOR'AN & ASSOMA'ES, LU-.. <br />.. <br />Inintol,41w, - <br />