Laserfiche WebLink
I ne T011owmg inrormauon is necessary to cnecK a uunuiny permit appiicauun iur cumplance wain uie umuny enveiupu requneniumz5 ni uie vvasnniyuwn Oldie <br />Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />N\ <br />Indicate if an area -weighted U-factor is used <br />for multiple fenestration elements within the <br />same fenestration category per Table C402.4; <br />provide area -weighted U-factor calculation <br />YES <br />Indicate if values are NFRC or default; if A2-1 <br />default then specify frame type, glazing <br />layers, gap width, low-e coatings, gas -fill <br />NA <br />C402.4.3 Permanent shading For each group of windows with similar <br />devices orientation and overhang or permanent <br />projection geometry, provide projection <br />factor calculations (Equation C4-6) for north <br />and non -north orientations <br />NA <br />C402.4.2 Single story spaces Provide list of enclosed, single story spaces <br />requiring skylights that exceed 2,500 sf. for each space identify <br />the space use, floor area, floor to ceiling <br />height, whether skylights are installed, and <br />any exception taken <br />Provide calculations for percentage of' <br />conditioned floor area located within a toplit <br />daylight zone; if exception is taken for spaces <br />where the total floor area minus the sidelit <br />zone area is less than 2,500 sf, include <br />percentage of conditioned floor area located <br />within a sidelit daylight zone in calculations <br />NA <br />Provide calculations for percentage of <br />skylight area in each space over 2.500 SF. OR <br />,\ <br />Provide calculations for skylight effective <br />aperture (Equation C4-5) for each space over <br />2,5(X) SF <br />NA <br />Indicate haze factor of skylight glazing <br />material or diffuser <br />NA <br />C410.2 Walk-in and Indicate insulation R-value in cooler and <br />warehouse cooler and freezer wall and ceiling assemblies <br />freezer envelope <br />NA <br />Indicate cooler and freezer door insulation R- <br />value; indicate method of minimizing <br />infiltration (strip doors, curtains, spring - <br />hinged doors, etc); provide automatic door <br />closure (or note exception taken) <br />NA For transparent reach -in doors and fixed <br />windows, indicate number of glass panes <br />(double or triple pane); identify whether the <br />interstitial spaces between panes is filled with <br />inert gas or if panes are heat -reflective treated <br />glass <br />ADDITIONAL EFFICIENCY CREDITS - ENHANCED ENVELOPE PERFORMANCE <br />NA C406.10 Enhanced envelope To comply with additional efficiency credit, <br />performance demonstrate envelope thermal performance <br />compliance via component performance; <br />provide WSEC envelope compliance reports <br />that demonstrate Proposed Total UA is 15% <br />lower than the Allowable Total UA <br />Page 5/8 <br />