10217 19TH AVE SE 2023-04-28
>
Address Records
>
19TH AVE SE
>
10217
>
10217 19TH AVE SE 2023-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2023 10:42:11 AM
Creation date
4/6/2023 8:16:44 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10217
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AM <br /> 1 TRANE <br /> Fan Performance <br /> Table 31. Electric heater voltage correction factors(applicable to auxiliary heat capacity) <br /> Nominal Distribution Capacity <br /> Voltage Voltage Multiplier <br /> 240 208 0.751 <br /> 240 230 0.918 <br /> 240 240 1.000 <br /> 480 440 0.840 <br /> 480 460 0.918 <br /> 480 480 1.000 <br /> 600 540 0.810 <br /> 600 575 0.918 <br /> 600 600 1.000 <br /> Table 32. Air temperature rise across electric heaters(°F) <br /> 3 Tons(a) 4 Tons 5 Tons(b) <br /> 1200 cfm 1600 cfm 2000 cfm <br /> Three Phase Three Phase Three Phase <br /> kW Stages WSC036E3,E4,EW WSC048E3,E4,EW WSC060E3,E4,EW <br /> 5.00 1 - - - <br /> 6.00 1 18.5 10.5 11.4 <br /> 10.00 2 - - - <br /> 12.00 2 36.2 22.3 21.5 <br /> 13.80 2 - - - <br /> 17.40 2 48.2 33.0 30.0 <br /> 17.60 2 - - - <br /> 23.0 2 - - 38.8 <br /> Notes: <br /> 1. For minimum design airflow,see airflow performance table for each unit. <br /> 2. To calculate temp rise at different airflow,use the following formula:Temp. rise across Electric Heater=kWx3414/ <br /> 1.08xCFM. <br /> (a)The minimum allowable airflow for a 3 ton with a 17.4 kW heater is 1080 cfm. <br /> (b)The minimum allowable airflow for a 5 ton unit with a 23.0 kW heater is 1900 cfm. <br /> Table 33. 6-10 tons air temperature rise across electric heaters(°F) <br /> 6 Tons 71/2 Tons 10 Tons <br /> 2000 cfm(a) 3000 cfm 4000 cfm(b) <br /> kW Stages WSC072E3,E4,EW WSC092E3,4,W WSC120E3,4,W <br /> 9.0 1 14.2 9.5 - <br /> 18.0 1 28.5 19.0 14.2 <br /> 27.0 2 42.7 28.5 21.3 <br /> 36.0 2 56.9 37.9 28.5 <br /> 54.0 2 - - 42.7 <br /> Notes: <br /> 1. For minimum design airflow,see airflow performance table for each unit. <br /> 2. To calculate temp rise at different airflow,use the following formula:Temp. rise across Electric Heater=kWx3414/ <br /> 1.08xCFM. <br /> (a)Minimum allowable airflow with a 36 kW heater for the WSC072E is 2400 cfm in the horizontal duct configuration. <br /> (b)Minimum allowable airflow with a 54 kW heater for the WSC120E is 4000 cfm. <br /> 48 PKGP-PRC013K-EN <br />