My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2410 RAILWAY AVE 2025-08-15
>
Address Records
>
RAILWAY AVE
>
2410
>
2410 RAILWAY AVE 2025-08-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2025 7:57:05 AM
Creation date
4/6/2023 12:02:49 PM
Metadata
Fields
Template:
Address Document
Street Name
RAILWAY AVE
Street Number
2410
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
642
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire Department --Steve Goforth-425.257.8104 <br />58. Access - The International Fire Code requires that all new structures shall provide Fire Department access <br />roads to within 150 feet exterior walking distance of all portions of the ground floor. Fire Department <br />access roads (Fire Lanes) shall provide a minimum of 20 feet in width of unobstructed, paved driving <br />surface, exclusive of shoulders, with a minimum clear height of 13'6". Inside turn radii must be 35 feet. <br />Outside turn radii must be 55 feet for ladder apparatus. Slope approach and departure angles must <br />not exceed 8 degrees. Fire lane grade must not exceed 10 percent. Fire lane construction must comply <br />with AASHTO H30 load capacity (74,000 GVW). Fire Lanes will be posted and maintained as required by <br />the Fire Department. Unorthodox access which meets code requirements but is too unusual for crews, <br />will not be allowed. Call Fire Marshal's Office for apparatus specifications. <br />59. Access - O.K. as shown on the site plan reviewed. <br />60. One (1) Knox Box is required. 2015 IFC, 506.1 Order box #3270. <br />61. Knox fire department connection caps are required for all OUTSIDE FDC and standpipe connection points. <br />Order two (2) caps #3043. Order Knox Products at www.everettfire.org. <br />62. Fire Lane Marking - Fire apparatus access roads shall be marked whenever necessary to maintain the <br />unobstructed minimum required width of roadways. Fire lanes shall be marked as follows: <br />a. Curbs shall be identified by red traffic paint with a 6-inch wide stripe on the top and front, extending <br />the length of the designated fire lane. <br />b. Rolled curbs shall be identified by red traffic paint with a 6-inch wide stripe on the curb, extending the <br />length of the designated fire lane. <br />c. Lanes without curbs shall be identified by red traffic paint with a 6-inch wide stripe on the pavement, <br />extending the length of the designated fire lane. <br />d. The words 'NO PARKING β FIRE LANE' shall be in 3-inch stroke white letters 18 inches in height, and <br />placed 8 inches measured perpendicular from the red paint stripe on the pavement. In most cases, both <br />sides of the access road shall be marked. Where long drives are to be marked, the repetitions shall <br />alternate sides of the drive. <br />e. Marking shall also include the addition of metal signs stating 'NO PARKING β FIRE LANE βTOW AWAY <br />ZONE β EMC 46.28.130' to be installed at intervals or locations designated by the Fire Code Official. The <br />signs shall be approximately 12 inches in width and 18 inches in height and have red letters on a white <br />background. Metal signs shall be installed on 2-inch metal pipes for private or public property and shall <br />be located so that the bottom of the sign is a minimum of 7 feet above the curb. Where fire lanes are <br />adjacent to buildings or structures and when approved or directed by the Fire Code Official, the signs <br />may be placed on the face of the building or structure. <br />f. Where directed by the Fire Code Official, specific areas shall be designated and those areas are to be <br />marked with diagonal striping across the width of the fire lane. Diagonal marking shall be used in <br />conjunction with painted curbs and/or edge striping and shall run at an angle of 30 to 60 degrees from <br />one side to the other. These diagonal lines shall be in red traffic paint, parallel with each other, at least <br />6 inches in width and 24 inches apart. Lettering shall appear as above. <br />Per field review from Fire Marshal's Office. <br />63. Fire Hydrants - Locations as planned are acceptable. <br />64. Fire flow for this project is 1750 GPM. <br />1500 G P M <br />+ 250 Hose allowance <br />=1750 GPM <br />65. Portable Fire Protection - A portable fire extinguisher with a minimum U.L. rating of <br />2-A:10-8:C shall be provided within 75 feet of travel on all floors of each building during construction <br />and prior to occupancy. 2015 IFC, Section 906.Office area. <br />=Page8 of 1 <br />SEPA18-004 <br />
The URL can be used to link to this page
Your browser does not support the video tag.